![Avalue Technology OFT-10WR1 Quick Reference Manual Download Page 10](http://html1.mh-extra.com/html/avalue-technology/oft-10wr1/oft-10wr1_quick-reference-manual_3024705010.webp)
OFT-10WR1
10 OFT-10WR1 Quick Reference Guide
4 Test Axis : X,Y and Z axis
5 Test time :30 min. each axis
6 System condition : Non-Operating mode
7. Reference IEC 60068-2-6 Testing procedures
Package vibration
test
1. PSD: 0.026G²/Hz , 2.16 Grms
2. Non-operation mode
3. Test Frequency : 5-500Hz
4. Test Axis : X,Y and Z axis
5. 30 min. per each axis
6. IEC 60068-2-64 Test:Fh
Shock Test
1. Wave form
:
Half Sine wave
2. Acceleration Rate
:
10g for operation mode
3. Duration Time
:
11ms
4. No. of Shock
:
Z axis 300 times
5. Test Axis: Z axis
6. Operation mode
7. Reference IEC 60068-2-29 Testing procedures
Test Eb : Bump Test
Package drop test
1 One corner , three edges, six faces
2 ISTA 2A, IEC-60068-2-32 Test:Ed
Mechanical Shock
Test
10Grms, IEC 60068-2-27, Half Sine, 11ms
Operating
Temperature
0°C ~ 40°C
Operating
Humidity
40°C @ 95% Relative Humidity, Non-condensing
Storage
Temperature
-20°C ~ 60°C
Note:
Specifications are subject to change without notice.