3.6.2.10.2 Console Redirection Settings
Item
Option
Description
Out-of-Band Mgmt Port
COM0
Microsoft Windows Emergency Management
Services (EMS) allows for remote
management of a Windows Server OS
through a serial port.
Terminal Type
VT100
VT100+
VT-UTF8
[Default]
ANSI
VT-UTF8 is the preferred terminal type for
out-of-band management. The next best
choice is VT100+ and then VT100. See
above, in Console Redirection Settings page,
for more Help with Terminal Type/Emulation.
Bits per second
9600
19200
57600
115200
[Default]
Selects serial port transmission speed. The
speed must be matched on the other side.
Long or noisy lines may require lower
speeds.
Flow Control
None
[Default]
Hardware RTS/CTS
Software Xon/Xoff
Flow Control can prevent data loss from
buffer overflow. When sending data, if the
receiving buffers are full, a
‘stop’ signal can
be sent to stop the data flow. Once the
buffers are empty, a
‘start’ signal can be sent
to re-start the flow. Hardware flow control
uses two wires to send start/stop signals.