Avalue Technology CAXA0-DC Quick Reference Manual Download Page 6

CAXA0-DC 

6    CAXA0-DC Quick Reference Guide

 

 

Sine Vibration test (Non-operation) 

1 Test Acceleration : 2G 

2 Test frequency : 5~500 Hz 

3 Sweep

1 Oct/ per one minute. (logarithmic) 

4 Test Axis :    X,Y and Z axis 

5 Test time :30 min. each axis 

6 System condition : Non-Operating mode 

7. Reference IEC 60068-2-6 Testing procedures 

 

Package Vibration Test: 

1 Test PSD : 0.026G²/Hz , 2.16 Grms 

2 Test frequency : 5~500 Hz 

3 Test axis : X,Y and Z axis   

4 Test time : 30 minutes per each axis 

5 IEC 60068-2-64 Test Fh 

Mechanical Shock 

Test 

1 Wave from : Half Sine wave 

2 Acceleration Rate : 10g for operation mode 

3 Duration Time : 11ms 

4 No. of shock : Z axis 300 times 

5 Test Axis : Z axis 

6 operation mode 

7 Reference IEC 60068-2-27 testing procedures   

  Test Eb : Shock Test 

Drop Test 

Package drop test 

Reference ISTA 2A, Method : IEC-60068-2-32 Test:Ed 

Test Ea : Drop Test 

1 Test phase : One corner, three edges, six faces 

2 Test high : 96.5cm 

3 Package weight : 1Kg 

4 Test drawing 

Operating 

Temperature 

0°C to 40°C (32°F to 104°F) work with tablet 

Operating 

Humidity 

15%~95% Relative Humidity, Non-Condensing 

Storage 

Temperature 

-20°C to 60°C (-4°F to 140°F) 

Other Test 

In house ESD testing 8KV contact and 15KV Air Criteria B 

 

Summary of Contents for CAXA0-DC

Page 1: ...Part No E2017CDC0A1R CAXA0 DC Desktop Cradle Quick Reference Guide 2nd Ed 26 March 2021 Copyright Notice Copyright 2021 Avalue Technology Inc ALL RIGHTS RESERVED...

Page 2: ...ERFERENCE AT HIS OWN EXPENSE A Message to the Customer Avalue Customer Services Each and every Avalue s product is built to the most exacting specifications to ensure reliable performance in the harsh...

Page 3: ...Guide 3 Content 1 Getting Started 4 1 1 Safety Precautions 4 1 2 Packing List 4 1 3 System Specifications 5 1 4 System Overview 8 1 4 1 Bottom View 8 1 5 System Dimensions 9 2 Hardware Configuration...

Page 4: ...urges Only experienced electronics personnel should open the PC chassis Caution Always ground yourself to remove any static charge before touching the CPU card Modern electronic devices are very sensi...

Page 5: ...reference voltage 250V test voltage 1500V Power input 19V DC in Indicator Light link indicator LED LED light up when tablet connected to the Desktop cradle Mechanical Power Type 19V DC In Power Conne...

Page 6: ...echanical Shock Test 1 Wave from Half Sine wave 2 Acceleration Rate 10g for operation mode 3 Duration Time 11ms 4 No of shock Z axis 300 times 5 Test Axis Z axis 6 operation mode 7 Reference IEC 60068...

Page 7: ...Quick Reference Guide CAXA0 DC Quick Reference Guide 7 Note Specifications are subject to change without notice...

Page 8: ...CAXA0 DC 8 CAXA0 DC Quick Reference Guide 1 4 System Overview 1 4 1 Bottom View Connectors Label Function Note DC IN DC Power in connector LAN RJ 45 Ethernet connector USB 3 x USB2 0 connector...

Page 9: ...Quick Reference Guide CAXA0 DC Quick Reference Guide 9 1 5 System Dimensions Unit mm...

Page 10: ...CAXA0 DC 10 CAXA0 DC Quick Reference Guide Unit mm...

Page 11: ...Quick Reference Guide CAXA0 DC Quick Reference Guide 11 2 Hardware Configuration Note If you need more information please visit our website http www avalue com tw...

Page 12: ...CAXA0 DC 12 CAXA0 DC Quick Reference Guide 2 1 Installing Table Top Docking Station Step 1 Slide the tablet into the table top docking station...

Reviews: