40
Safety
Label
© Travis Industries
4151204
100-01430
Safety Label
The safety (listing) label is attached to the operating tag (chained to the heater near the gas control
valve). A copy is shown below
Report No. 0028GN101S
Certified for USA
and Canada
V
e
nted Gas Fireplace Heater
Radiant Plus Small Insert
Tested to:
ANSI Z21.88-2014/CSA
2.33-2014 “V
ented Gas Fireplace Heater”, CGA
2.17-M91 (R2009) “Gas-fired
appliances for use at high altitudes”, and CSA
P
.4.1-2009 (R2014) T
esting method for measuring annual fireplace
efficiency
.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,
ANSI Z223.1/NFP
A 54, or Natural Gas and Propane Installation Codes, CSA
B149.1.
This appliance must be installed in accordance with the current Standard CAN/CSA
Z240 MH, Mobile Housing,
in Canada or with the Manufactured Home Constructions and Safety Standard, T
itle 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable,
ANSI/NCSBCS
A225.1/NFP
A 501A, Manufactured Home
Installation Standard.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the optional factory conversion kit must be used. Part No. 250-03813 kit may be used.
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes. See owner
’s
manual for details. This appliance is not convertible for use with other gases, unless a
certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer
’s
installation instructions. Use only an approved direct vent system to vent this appliance to the exterior
. See
owner
’s
manual for approved brands of venting.
If the vent-air intake system is disconnected for servicing or any other reason, it must be resealed and / or reinstalled.
W
ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to the owner
’s
information manual provided with this appliance. For assistance or additional
information consult a qualified installer
, service agency or the gas supplier
.
VENTED GAS FIREPLACE HEA
T
ER - NOT FOR USE WITH SOLID FUEL
Minimum Clearances to Combustibles
Enclosure minimum height Enclosure minimum width Enclosure minimum depth
19.75” (502mm)
27” (686mm) 15” (381mm)
Base of Insert to Mantel Base of Insert to T
op Facing
Minimum chimney flue size
See Owner
’s
Manual
See Owner
’s
Manual
7” (178mm)
FAN TYPE VENTED CIRCULA
TOR (OPTIONAL)
Blower Electrical Rating: 120V
., 0.55
Amps, 60 Hz, 66 W
atts (Part No. 99000192 fan or blower assembly may be used)
For use only with barrier Part No. 250-03378 or 250-03814.
Follow installation instructions
Minimum Inlet Pressure (inches W
.C.)
Maximum Inlet Pressure (inches W
.C.)
Manifold Pressure on “HI” (inches W
.C.)
L.P
.
11
”
13”
10.2”
N.G. 5.5”
7”
3.5”
Input Rate on “HI” (BTU/Hr)
Input Rate on “LO” (BTU/Hr)
Orifice Size - (DMS)
L.P
.
25,000
13,000
#53
N.G. 25,000 12,000 #42
This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4,500 feet (0-1370m).
For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See owner
’s
manual for information on making these changes.
2016
2017
2015
Feb.
Mar
.
Jan.
May
Jun.
Apr
.
Aug.
Sep.
Jul.
Nov
.
Dec.
Oct.
MANUF
ACTURE DA
TE:
W
ARNING: This fireplace has been converted for use with a gas fireplace insert only and cannot be used for
burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
W
ARNING: Failure to install this appliance per the manufacturer
’s
instructions or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury
.
12521 Harbour Reach Drive
Mukilteo, W
A
98275
Manufactured by:
www
.travisproducts.com
CAUTION:
Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.
1202
Summary of Contents for Radiant Plus Small Insert
Page 32: ...32 Operation Travis Industries 4151204 100 01430 Remote Control Operation ...
Page 33: ...Operation 33 Travis Industries 4151204 100 01430 Remote Control Operation continued ...
Page 34: ...34 Operation Travis Industries 4151204 100 01430 Remote Control Operation continued ...
Page 35: ...Operation 35 Travis Industries 4151204 100 01430 Remote Control Operation continued ...