background image

Installation 

(for qualified installers only)

7

Travis Industries

100-01136

4 0 4 0 8 0 9

Installation Warnings

Failure to follow all of the requirements may result in property damage, bodily injury, or even death.

This heater must be installed by a qualified installer who has gone through a training program for the

installation of direct vent gas appliances.

This appliance must be installed in accordance with all local codes, if any; if not, follow current ANSI

Z223.1 or NFPA 54.

In Manufactured or Mobile Homes this appliance must be installed to the applicable Mobile Home

Standards: Title 24 CFR, Criteria for Manufactured Home Installations, Sites and Communities, and/or
ANSI/NFPA 501A.       

This appliance may be installed in Manufactured Housing only after the home is site

located.   

This appliance is designed for natural gas or propane (LP).  Check the sticker on top of the gas control

valve.

All exhaust gases must be vented outside the structure of the living-area.  Combustion air is drawn from

outside the living-area structure.

Notify your insurance company before hooking up this appliance.

The requirements below are divided into sections - all requirements must be met simultaneously.

Packing List

• Log Set with Coals     • Propane Conversion Kit      • Latch Tool

Installation Preparation

HINT:

If converting to LP, convert the appliance prior to installation.

HINT:

Install the logs last - they are fragile.

HINT:

When determining the location of the stove, locate the wall studs (for horizontal penetrations)
and ceiling trusses (for vertical penetrations).  You may wish to adjust the stove position
slightly to ensure the vent does not intersect with a framing member.

HINT:

Fumes and smoke from the paint curing and oil burning off the steel may occur the first time
you start this heater.  This is normal.  We recommend you open windows to vent the room.

Stove
Clearances

Mobile Home
Requirements

10" Min.

4" Min. 

Straight Installations

Corner Installations

With this clearance, the vent is 

centered 15-3/8" from the wall.

45°

4" Min.

With this clearance, the vent is 

centered 12" from the back wall, 

24” from the side wall.

When the stove is installed in a mobile home, it must be bolted to the floor and the appliance
grounded (use the blower with a grounded circuit or other suitable grounding method - current
ANSI/NFPA 70).

Summary of Contents for Direct Vent Freestanding Stove

Page 1: ...lier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer s...

Page 2: ...e installation and operation of your new heater an easier and more enjoyable experience We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your heat...

Page 3: ...Elbows 11 Horizontal Terminations 12 Vertical Term s with Two 90 Elbows 13 Termination Requirements 14 Finalizing the Installation 15 Opening the Door 17 Log Set and Coal Installation 18 Operation Saf...

Page 4: ...natural gas NG or propane LP Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard Check the label above the gas control valve to make sure it ma...

Page 5: ...ce The pilot flame must contact the thermopile and thermocouple see the illustration to the left If it does not turn the gas control valve to OFF and call your dealer A A This unit is not for use with...

Page 6: ...73 7 LP Heating capacity will vary depending on the home s floor plan degree of insulation and the outside temperature Efficiency rating is a product of thermal efficiency rating determined under con...

Page 7: ...ce company before hooking up this appliance The requirements below are divided into sections all requirements must be met simultaneously Packing List Log Set with Coals Propane Conversion Kit Latch To...

Page 8: ...54 The heater and gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1 2 psig 3 45 kPA For pressures under 1 2...

Page 9: ...on NOTE always use the high wind version if applicable Use a roof flashing and storm collar whenever passing through the roof Use a support box on exposed vent Vertical Vent Requirements Use a firesto...

Page 10: ...ts under Approved Vent Configurations the factory position is 1 Lift up the adjustment plate and move it so the correct notch falls into the slot on the adjustment bracket This restrictor is in positi...

Page 11: ...25 feet 30 feet NOTE Restrictor positions are based upon lab tests The ideal restrictor position may vary slightly especially when the termination is near the demarkation line Four 45 Offsets AAAAAAA...

Page 12: ...AAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA 5 feet 0 feet 10 max 0 feet 5 feet 0 feet 0 feet NOTE Horizontal sections require a 1 4 rise every 12 of travel 12 feet max NOTE A minimum 2 f...

Page 13: ...AAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA 5 feet 10 feet min 15 feet 20 feet 25 feet 30 feet 0 feet 38 max 5 feet 10 feet 15 feet 0 feet 5 feet 10 feet 15 feet 25 m...

Page 14: ...ance above any grade when adjacent to public walkways or driveways NOTE may not be used over a walkway or driveway shared by an adjacent building I Minimum 48 clearance from any mechanical air supply...

Page 15: ...rewed gas will come out of this port Clockwise lowers the flame while counter clockwise raises it 6 Let the heater burn for fifteen minutes Adjust the air shutters if necessary to achieve the correct...

Page 16: ...er however this will make the flames more blue For yellow flames close the air shutter however this may create less glow The flames should burn right off the top of the burner ports if they are too bl...

Page 17: ...h the top and bottom latch With the pawl free of the strike the door may be swung open Swing the left panel back When securing the door make sure the pawl fits over the strike before tightening Strike...

Page 18: ...paced 1 4 to 3 8 off of the burner holes Do not place logs over burner holes Top View A A A A AA AA AA A A Place the front logs on top of the burner These bolts insert into the holes in the logs AA AA...

Page 19: ...AA AA AA AA AA AA AA AA AA AA AA Place the left and right twigs as shown AA AA AA AA A A AA AA AA AA AA A AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA Place the ember chunk as shown St...

Page 20: ...nob This knob is used to control gas to the heater and for starting the pilot There are three positions ON OFF PILOT The pointer to the left of the knob indicates the position this knob is in Flame Ad...

Page 21: ...de the firebox escape If you smell leaking gas follow the directions on the cover IF YOU SMELL GAS c Turn the gas control knob to the PILOT position and press the knob in this will allow gas to flow t...

Page 22: ...F SE T TE MP TIM ER MI N Tim e Se t Tim e Ca nc el A u t o OF F ON Use this switch to turn the main burner on and off manually After the pilot has been started See the instructions included with the...

Page 23: ...his is the valve opening up and shutting down Blower Snap Disk This part can produce a clicking sound as it turns the blower on and off The appliance may creak with change of temperature Pilot Flame T...

Page 24: ...e following Check for burner for cracks warps or other damage Check the firebox and area around the pilot to make sure there is no warping or damage If any problem is found discontinue use and contact...

Page 25: ...OFF switch is turned to OFF The remote is too far away from the heater The remote control receiver is turned OFF One of the two remote control batteries is dead See Starting the Pilot Flame Pg 21 See...

Page 26: ...in burners are switched on and off using the electricity generated by the thermopile The ON OFF switch remote control or thermostat control the circuit to the main burner ON OFF MAIN BURNER What Preve...

Page 27: ...alve Replacement Parts 93006080 Blower 93006855 Orifice Burner 43 226 20032 BURNER ASS Y B31 LP NG 93006857 Orifice Burner 46 98900751 Piezo Igniter 93006506 Control Valve Natural Gas 93006516 Pilot A...

Page 28: ...d with this appliance For assistance or additional infor mation consult a qualified installer service agency or the gas supplier WARNING Operation of this appliance when not connected to a properly in...

Page 29: ...condensation c Any damage to the unit combustion chamber heat exchanger or other components due to water or weather damage which is the result of but not limited to improper chimney venting installat...

Page 30: ...onto the orifices AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AA AA AA AA A A AAA AAA AAA AAA AAA AAA Mixing Tubes Orifices Replace the pilot hood after replacing the burner Burner Replacement Make sure the b...

Page 31: ...identify the correct orifices Front Rear LP 55 54 NG 46 43 c a AA AA AA A A Slide the air shutters all the way to the left Front Orifice Manifold Rear Orifice b Manifold 5 16 4 Remove the pilot orifi...

Page 32: ...ed Screwdriver or T 20 Torx Install the LP regulator Use the screws included with the LP regulator Tighten to approximately 25 Lbs torque c Slotted Screwdriver or T 20 Torx Place the LP label on the p...

Page 33: ...firebacks along the sides of the firebox Secure with the fireback clips and the screws removed in step b AA AA AA A A AA AA AA A A d Gold Door Part 99300528 Follow the directions to the right to inst...

Page 34: ...nuts Gold Trivet part 93005045 Note The vent must be detached before installing the trivet install this component before installing the vent Follow the directions to the right to install the optional...

Page 35: ...versions Follow the requirements and use the equipment listed in the illustration to the right to install this appliance into an interior masonry chimney Maximum vertical rise is 40 Minimum vertical r...

Page 36: ...ation Requirements 14 How to Measure Vent Lengths 10 Installation Options 6 Installation Preparation 7 Leaking Gas See Inst on Cover Lifting Flames 16 Listing Label Safety Label 28 Log Installation 18...

Reviews: