Radiant (Small or Large) Blower
Installation Instructions
(sku 99000192)
Page 1 of 4
17601904 - 12/15/15
© Travis Industries, Inc.
Packing List
Blower
Assembly
Power
Cord
Assembly
Snap
Disk
(2)
Grommets
Cable
Holder
Screw (8-32 x 3/8”)
Using the Insert Wire Kit with this Blower
The insert wiring kit (97200315) may be used with this blower kit. Follow the steps below to install.
-
The Radiant blower includes a power cord assembly that must be dis-assembled. Remove and discard the power cord
from the assembly (remove the strain relief). Then attach the bracket to the insert (see step 5 below). This bracket will
be used as a grounding tab.
-
Install the wiring kit following the instructions included with the kit. The power cord was removed so steps 1 and 2 may
be disregarded. Attach the conduit to the insert, using the 7/8” diameter hole on the right side of the insert.
-
Follow the installation instructions below to install the blower. For step 4, attach the molex connector from the blower to
the wiring kit and the grounding wire to the power cord bracket.
Remove the Knock-Out - Designer and Universal Faces
When using the Designer or Universal face, remove the knock-out on the side of the face for the power cord.
Installation
WARNING
:
Do not plug the blower in until it is fully installed and grounded.
Do not connect 110-120 VAC to the gas control valve or wiring system of this appliance.
NOTE
:
Install the blower after the insert is in place. The blower is only secured with vibration-damping
grommets. The blower will dislodge if the insert is tipped forward.
1. Place the grommets over the studs on the baseplate of the insert as shown below.