F
EATURES AND
S
PECIFICATIONS
P
AGE
5
Installation Options:
¥ Freestanding
¥ Freestanding in an Alcove
¥ Masonry Fireplace Insert
¥ Factory-Built (Z.C.) Fireplace
Insert
Features:
¥
Works During Power Outages
(utilizes millivolt system)
¥
High Efficiency; Up to 80% for Natural
Gas, 82% for LP (Steady State)
¥
Optional Thermostat or Remote Control
¥
Realistic "Wood Fire" Look
¥
Convenient Operating Controls
¥
Variable-Rate Heat Output
¥
Quiet Blower for Effective Heat
Distribution
¥
Low Maintenance
Heating Specifications:
700 Natural
Gas
700 LP
(propane)
Approximate Maximum Heating Capacity (in square feet)*
600 - 1600
600 - 1600
High Burn Input Rate (In BTU's)**
31,000
31,000
Low Burn Input Rate (In BTU's)**
18,000
17,000
AFUE Efficiency
70.0 %
70.0 %
*
Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also
affected by the natural gas or LP BTU rating.
**
To measure the net BTU's, multiply the BTU input by the efficiency percentage (80% for natural gas, 82% for LP).
700 Dimensions
23 5/8"
18 1/2"
HEIGHT*:
Without Legs 20 1/8"
With Pedestal 31 3/8"
With Brass Legs 28"
With Cast Legs 28"
With Black Legs 26 5/8"
* Subtract 1 1/8" to reach
the base of the flue collar
3 1/4"
Vent Opening Diameter = 4" (Both)
Weight = 175 Pounds
Electrical Specifications:
Blower Electrical Rating:
115 Volts, 1.3 Amps, 60 Hz (150 watts on high)
Fuel:
The heater is designed either for natural gas or for propane (but not for both). Check the sticker
on the top of the gas control valve.
Emissions:
This unit has passed the ANSI emission standards for vented room heaters as tested by Warnock
Hersey, LTD.
Summary of Contents for 700 B-Vent