Installing Your Beverage Refrigerator Continued  

 

INSTALLING: 

When installing the beverage refrigerator under a counter, follow the recommended spacing dimensions shown. 

 

 

 

To ensure proper service access and ventilation, allow 
between 2-3 inches of clearance at the back as shown 
in the diagram. 

 

 

The installation should allow the unit to be pulled 
forward for servicing, if necessary. 

 

 

A standard electrical supply (115 VAC only, 60 Hz), 
properly grounded in accordance with National 
Electrical Code and local codes and ordinances is 
required. 

 

IMPORTANT

Once you are ready to install it in a 

cabinet or directly on the floor, you must adjust the 
feet to level the beverage refrigerator. 

 

LEVELING

The beverage refrigerator should be installed on a firm and level surface that will be able to support the entire weight of 
a fully loaded unit.  It is important for the beverage refrigerator to be leveled in order to work properly.  It can be raised 
or lowered by rotating the plastic sheaths around each of the feet on the bottom of the machine.  If you find that the 
surface is not level, rotate the feet until the beverage refrigerator becomes level.  You may need to make several 
adjustments to level it.  We recommend using a carpenter’s level to check the machine.  Turn the leveling feet to the 
right to lower that side of the refrigerator.  Turn the leveling feet to the left to raise that side of the refrigerator. 

 
RECOMMENDED GROUNDING METHOD

For your personal safety, this appliance must be grounded.  It is equipped with a power supply cord having a 3-prong 
grounding plug.  To minimize possible shock hazard, the cord must be plugged into a mating 3-pronged wall socket, and 
grounded in accordance with the National Electrical Code and local codes and ordinances.  If a mating wall socket is not 
available, it is the personal responsibility of the customer to have a properly grounded, 3-prong wall receptacle installed 
by a qualified electrician. 
 

ELECTRICAL SHOCK HAZARD! 
• Plug into a grounded 3-prong outlet 
• Never remove the grounding prong from the plug 
• Never use an adapter to bypass the grounding prong 
• DO NOT use an extension cord 
• Failure to follow these instructions can result in fire, electrical shock, or personal injury

 

 
Before you move your beverage refrigerator into its final location, it is important to make sure you have the proper 
electrical connection.  A standard electrical supply (115 V, 60Hz), properly grounded in accordance with the National 
Electrical Code and local codes and ordinances, is required.  It is recommended that a separate circuit, serving only your 
beverage refrigerator, be provided.  Use receptacles that cannot be turned off by a switch or pull chain. 
 
The fuse (or circuit breaker) size should be 15 Amps. 

Summary of Contents for ABR241SG

Page 1: ...USER S GUIDE Installation Operation and Maintenance for your product Built In Beverage Refrigerator Model ABR241SG www avallon com 1 866 471 7427 ...

Page 2: ...tely unplug the unit if it makes strange sounds emits smells or smoke comes out of it and contact customer service Do not remove any part of the casing unless instructed by an authorized technician You should never attempt to repair the unit yourself Contact customer service for service options if the unit needs service GENERAL SAFETY To prevent back and other types of injuries use at least two pe...

Page 3: ...ckaging labels and materials removed from the unit Be sure to keep track of all included parts and pieces before discarding packaging materials It is advised that you keep the original box and packaging materials in case you are ever to move or ship the appliance in the future Allow the unit to stand for at least 24 hours before you use it this allows the cooling components time to settle from tra...

Page 4: ...e rating label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warranty Model Number Serial Number Date of Purchase To better serve you please do the following before contacting customer service If you received a damaged product immediately contac...

Page 5: ...umber from the product label and write down before installing the beverage refrigerator Internal Fan This is an air cooled unit equipped with an internal fan that maintains a consistent internal temperature Carbon Filter A built in carbon filter protects your beverage by acting as a natural barrier against harmful odors Control Panel Slide Out Shelf Door Lock Door Handle Seamless Stainless Door Fr...

Page 6: ...ge refrigerator has been designed for free standing or built in installation In every case there must be adequate ventilation and access for service Free standing installation A free standing installation will allow you to install the beverage refrigerator in almost any place you desire You must follow the stated instructions for electrical requirements and leveling the beverage refrigerator Built...

Page 7: ...he leveling feet to the right to lower that side of the refrigerator Turn the leveling feet to the left to raise that side of the refrigerator RECOMMENDED GROUNDING METHOD For your personal safety this appliance must be grounded It is equipped with a power supply cord having a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 pronged wall socket and ...

Page 8: ...hould situate on the shelf track 4 Gently push the shelf back towards the rear of the unit until the right side metal guide post meets the vertical indentation in the plastic interior cabinet 5 Gently set the right side of the shelf down on the shelf track The shelf should move forwards and backwards smoothly REMOVING THE SHELVES 1 Open the door completely 2 Make sure the shelf is pushed back comp...

Page 9: ...rements 50 F is the highest temperature on this unit DECREASE TEMPERATURE Press this button to decrease the temperature by one 1 degree increments 34 F is the lowest setting on this unit INTERIOR LIGHT Press this button to cycle through the different internal light settings There are four light settings Constant Blue Constant White Automatic Blue and Automatic White Press this button to cycle thro...

Page 10: ...us starting back at the beginning of the progression TIP Close the door to determine if the light is currently in Constant Mode or Automatic Mode Holding the light button for three seconds will turn the lights on and off If you power the lights off they will remain off even when the door is open Hold the light button for three seconds again to turn the lights back on The automatic light feature is...

Page 11: ...einsert the shelves and beverages 6 Reconnect power to the unit EXTERIOR CLEANING The door and cabinet may be cleaned with a mild detergent and lukewarm water solution such as two 2 tablespoons of baking soda to one 1 quart of water Do not use solvent based or abrasive cleaners Use a soft sponge and rinse with clean water Wipe with a soft clean towel to prevent water spotting If the door panel is ...

Page 12: ... in the cabinet to allow air flow Keep the refrigerator away from direct sunlight or other heat sources Read and follow the Installation Clearance Requirements section Close the door tightly and do not open the door too frequently or for long periods of time The beverage refrigerator is making strange noises Certain sounds are normal The unit is not level or is touching another appliance Read the ...

Page 13: ...MPERATURE RANGE 34 to 50 F DIMENSIONS HEIGHT X WIDTH X DEPTH 34 5 X 23 9 X 23 7 WEIGHT 114 Pounds NOTE Technical data and performance information is provided for reference only Specifications are subject to change Check the rating label on the beverage refrigerator for the most accurate information Storage capacity based on standard 12 oz cans The refrigerator may experience decreased cooling effi...

Page 14: ...allation unauthorized service mainte nance negligence unauthorized installation or modification or commercial use Labor service transportation and ship ping charges for the removal and replacement of defective parts beyond the initial 12 month period Products that have been modified to perform outside of specifications without the prior written permission of Avallon Products lost in ship ment or t...

Page 15: ...736 Bee Cave Rd STE 1 188 West Lake Hills TX 78746 Toll Free 1 866 471 7427 Web http www avallon com E mail service avallon com Product contents and specifications may change without notice Copyright 2015 Avallon Gobal LLC ...

Reviews: