Built-in automatic protections
Cleaning the air filter
Automatic Defrost
When operating at low room temperatures, frost may build up on
the evaporator. If this happens, the
Power LED will begin blinking
and the unit will automatically stop for a short time to carry out its
automatic defrosting procedure.
Overload Protection
In the event of sudden power loss, to protect the compressor there
is an automatic 3-minute delay until the compressor will restart.
Excess dust can cause airflow to become restricted which will
reduce efficiency and it can damage to the unit. The filter should be
cleaned regularly.
•
Ensure the unit is switched off and unplugged from the mains
power.
•
Remove the filter from the unit.
•
Use a vacuum cleaner to remove dust from the filter.
•
Rinse the filter under running water.
•
Allow the filter to air dry completely before reinstalling.
Warning: Do not touch the air inlet or the evaporator surface,
located behind the filter. Doing so could cause injury. Always
ensure the filter is completely dry before reinstalling into the unit.
Specifications
S-80
S-95
S-150
S-200
S-290
BTU
5000
7000
8000
9000
10000
Circulation
290m3/h
290m3/h
290m3/h
310m3/h
310m3/h
Temp’ range
16-32ºC
16-32ºC
16-32ºC
16-32ºC
16-32ºC
Power
1460W
2050W
2345W
2600W
2930W