AV-GAD EasyLoader AV-701 End User Operating Manual Download Page 1

 

 

EasyLoader  

 

End User Manual

Downloaded from:

 http://www.guardianalarms.net

Summary of Contents for EasyLoader AV-701

Page 1: ...EasyLoader End User Manual Downloaded from http www guardianalarms net ...

Page 2: ...HONE NUMBER 14 SOUNDER 14 AV 707 Keypad 15 INTRODUCTION 15 LCD DISPLAY 16 KEY ENTRIES 16 SETTING NEW CODE FOR THE AV 707 16 SETTING FOLLOW ME TELEPHONE AT AV 707 17 Displaying System Information 18 ALARM MEMORY DISPLAY 18 EVENTS DISPLAY 18 TROUBLE CONDITIONS 18 Setting System Features 19 CHANGING CODES 19 DELAYS DELETE 19 Testing Your System 20 SIREN AND BATTERY TEST 20 DETECTION DEVICES TEST 20 T...

Page 3: ...tion Type Zone Description Type 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 Installation Data Installer CS Information Programmed Telephones Phone Phone Mobile Account No Installation date Contact Person Zone at Home Mode Siren Times Silent Zones Notes ...

Page 4: ...ur system efficient as intended it s recommended to test the system daily upon arming and weekly testing the siren and detection devices Read the Testing your System section If your system does not function properly contact your installer Keep the keypad dry clean the keypad with dry cloth Never disconnect the main AC to your system Glossary Your security system has been designed to offer the late...

Page 5: ...ay Keypad display Provides alphanumerical readout of zone status and messages Entry Delay The Entry Delay is the period allowed for someone to enter the premises and disarm the system Entry Exit Zone The entry exit door or zones are designated by your installer to be used for entering and leaving the premises when the system is armed Exit Delay The Exit Delay is the period allowed for users to lea...

Page 6: ...ion about the system Information about the system is displayed Commands are entered on the keypad by pressing one key at a time LCD Shortening for Liquid Crystal Display This type displays full texts zone locations messages etc LED Shortening for Light Emitting Diode LED is a modern bulb LED visually displays the system status and confirms the functions Master Code The Master Code is a 4 to 6 digi...

Page 7: ...sers to arm and disarm the system and to bypass zones Keep the code confidential to ensure maximum system security Zone also called area An area protected by a security device For example a room protected by a motion detector as Zone number 1 while a door protected by a magnetic contact as Zone number 3 Your installer will inform you which zones have been set up on your system The AV 701 contains ...

Page 8: ...nd a constant tone to indicate that the system must be disarmed Enter your code at keypad if an error made while entering the code press 9 and enter the code again After six wrong entries the keypad locks itself for 30 seconds keys do not respond during this period When a correct code is entered the Armed light shuts OFF and the sounder is silent your system is now disarmed Enter your code before ...

Page 9: ...now be bypassed When arming the system with bypassed zones it is always recommended to review the list of bypassed zones before entering your code to arm the system After bypassing the desired zones enter your code to arm the system Arming Choices Home Mode Arming with Home mode automatically bypasses the zones programmed as Group Bypass This feature allows you to arm the system and remain on the ...

Page 10: ...rogramming Mode hold down 8 and 1234 hold down 1 t is displayed and type hour and minutes Hold down 1 and wait for the time to be displayed Holding down 0 1 keys to program the time is possible only if the Automatic Arming is disabled otherwise an Error warning is displayed Automatic Arming will not operate if the system time has not been set blinking h Automatic Arming will not operate if the con...

Page 11: ...y and Panic 0 Shunt and 1 Siren Display and Setting of System Time Hold down 0 key and then hold down 1 three LEDs are blinking wait for the time to be displayed in 4 digit format To set new time hold down key 0 and then hold down 1 Do not wait for time display enter the new time in 24 hour format The local clock time is not stored in the system memory clock must be adjusted after power up After p...

Page 12: ...ing when a Fire Zone is troubled Two LEDs Flashing Left Most LEDs In user code programming mode rapid blinking indicates code or code index to be entered In Disarmed mode the two left most LEDs are blinking to indicate 24H alarm mode Zone number will also be displayed Three LEDs Flashing In Disarmed mode rapid blinking indicates AC power failure AC power failure event is displayed in Events Histor...

Page 13: ...ter power up to remind user to set the system time h will be removed after time setting using keys 0 and 1 H Hold Up Upon Panic triggering from Keypad o Opening Indicates system opening Disarming Followed by user number when events log is displayed L Low Battery Indicates Low Battery Call your installer P Program System is in programming mode t Tamper Indicates zone s Tamper alarm U Update Confirm...

Page 14: ... entered 5 Enter the code index you want to delete 1 for code No 1 2 for code No 2 etc 6 The two right most LEDs blink to indicate that the system is waiting for a new code 7 Hold down 9 key to quit code setting If user code is not entered the code is voided A short beep confirms that the code has been deleted Setting the Follow Me Telephone Number The Follow Me feature is applicable only with the...

Page 15: ...Two confirmation beeps Follow Me number programming Two confirmation beeps During alarm requires programming Intermittent beep until alarm reset AV 707 AV 706 AV 705 Keypads LCD type for PRO panels Introduction The AV 707 EasyKey is the future generation keypad with the New Look shape fully customized microprocessor based remote station multitasking functions with 32 Keypad ID s comply with year 2...

Page 16: ... time is displayed in the five rightmost positions The LCD displays often the installer LOGO the logo is editable For displaying zone description hold down 3 key twice To save power the LCD and keys backlight turns OFF after 60 seconds of no typing activity it turns ON again when an alarm occurs Most of the accessible functions with the LCD Keypad are similar to those of the AV 701 seven segments ...

Page 17: ... displaying the code At any time after the control panel response you can start typing a new index there is no need to wait for the announcement to disappear To erase an existing code Enter user index number 01 02 03 hold down simultaneously keys and followed by E erased will be displayed The Master code number 01 cannot be erased Type 99 followed by to exit Setting Follow Me Telephone at AV 707 T...

Page 18: ...events are displayed from the most recent events to the oldest ones 3 0 Shunt and 5 Chime Display Last 2 Users Hold down 0 and then hold down 5 to display user number and System opening or closing time o is displayed for Opening Disarming c is displayed for Closing Arming Events Display Events are displayed as following XX Event number from 01 to 99 then HH_MM Hour and Minutes Event Time Event ala...

Page 19: ...Visual feedback from the keypad display upon entering of code This feature indicates the code entry progress and is most practical when the keypad buzzer is disabled at Home Group Bypass mode or if selected by programming Entry of code by user or installer is confirmed at keypad display Display segments will light up clockwise indicating the sequence of the entered digits Note After six unsuccessf...

Page 20: ...sarm the system main AC is still off few times if L is displayed your battery is faulty call your installer Detection Devices Test Test 7 Key 7 FAULT FIND Fault Find enables testing of all detection devices Fault Find mode can be entered only during the 15 seconds following system Disarming Fire 24H or Panic alarm will stop Fault Find mode Hold down 7 key confirmed by F on Keypad display Activate ...

Page 21: ...llow shunt indicator constantly on Arm and disarm the system the indicator light should turn off Green indicator blinks continuously when you attempt to arm the system Sign is displayed and arming denied system can not be Armed with an open instant or 24H zone Hold down 3 key the zone s in trouble will be displayed Check the cause an open window movement detected by detector or else 1 Press 0 key ...

Page 22: ...r installer immediately Check your telephone line Siren was triggered but programmed phone numbers were not dialed 1 Faulty dialer 2 Faulty phone line or phone off the hook 3 Mistaken report of alarm 1 Hold down 6 key dialer test automatically dialed numbers will be displayed test takes several minutes 2 If the telephone line to the alarm control has been disconnected reconnect it 3 Malfunction of...

Page 23: ...ty There are no warranties express or implied which extend beyond the description of the face hereof There is no express or implied warranty of merchantability or a warranty of fitness for particular purpose Additionally this warranty is in lieu of all other obligations or liabilities on the part of Av Gad Any action for breach of warranty including but not limited to any implied warranty of merch...