36
2. FEATURE PROGRAMMING AT INSTALLER LEVEL
2.1
Programming Sheet (version 2.17C)
For AV-2005 refers to zone 1 to 5 only.
(Fits AV-2005, AV-2008, AV-2005/8 PRO)
Factory Default Program is as shown in table; Blank Square means no default program
TELEPHONES
SIGNAL TEST & AUTO ARMING TIME
Tel. 1
Tel. 2
Tel. 3
Tel. 4
Test Time
Auto Arm Time
010
011
012
013
014
016
(00:01)
00:00
Tel. 1 is also the ‘Follow Me’. Maximum 16 4 pauses
Tel. 2 and 3 are communicator option.
Test signal to central station (014). Codes are defined at
Addresses: 072, 073, 237 & 255. Enter time in 24 hour
format
To insert * in the phone number, program system to dial in DTMF, Hold-down keys # and * (as panic); ‘A’ will
be displayed. For Pause during dialing, hold-down key ‘0’.
ZONE FEATURES
Feature
Address
1
2
3
4
5
6
7
8
Fire zones
019
Zone In Use
020
1
2
3
4
5
6
7
8
Entry/Exit Delay 1
021
1
Entry/Exit Delay 2
022
Entry / Exit Follower
023
2
24-Hours Zone
024
Day Zone
025
Green Reset Zone
026
1
2
3
4
5
6
7
8
Swinger Shutdown
027
Chime
028
1
2
NON-EOL Resistor
029
1
2
3
4
5
6
7
8
Enable Zone Tamper
030
Delayed Power-Up
031
Fast Response
032
Group Bypass # 1
033
Group Bypass # 21
034
Manual Bypass
035
1
2
3
4
5
6
7
8
Siren Out
036
1
2
3
4
5
6
7
8
Alarm 1 (A1) Output
037
1
2
3
4
5
6
7
8
Reserved
038
SLO output (output 3)2
039
Dial on Alarm
040
1
2
3
4
5
6
7
8
Sounder on Alarm
041
1
2
3
4
5
6
7
8
Normally Open (N.O.)
042
Panic Zone
045
1
Group Bypass # 2 – Available at PRO version 2.16 and latter.
2
SLO is a non-timed output. SLO = Selective output.
Address 043, 044 are applicable only with special Saturday (Shabbat) version.
Keypad Panic Alarm
050
Tamper Alarm
051
Siren on Panic
1
Tamper zone as 24H zone
1
Alarm 1 active on Panic
2
Alarm 1 active on Tamper
2
Reserved
3
Reserved
3
SLO On Panic
(4)
SLO on Tamper
4
Telephone Report
(5)
Tel. Line fail activates buzzer
5
Reserved
6
Tel. Line fail activates siren
6
Reserved
7
Dialer Report AC Power Fail
7
Values marked with ( ) are Factory Default Program. * Available with PRO type only
TIME-OUTS
AC fail
report
delay
Zone
Respons
e
time
Entry
Delay 1
Entry
Delay 2
**
Exit
Delay
**
Siren
Time
ON Siren
Time
OFF
Siren
Time
A1
Time
Reserv
ed
Chime
Time
Abort
Delay
Minutes
m. Sec
Sec's
Sec's x
4
Sec's x 4
Minute
s
Sec's
Sec's
Sec's
-
Beeps
Sec's
058
059
060
061
062
063
064
065
066
067
068
069
1
0
0
5
1
2
0
0
0
8
0
4
1
5
0
4
3
0
0
0
0
3
0
4
Note: Address 059 adjusts the response time of zones selected as ‘Fast Response,’ applicable with inertia sensors. ** Maximum value = 64.