Bella  I  is  an  outdoor  Siren  &  Strobe  for  intruder  and  fire  alarms,  compatible  with  DC  12V 
alarm panels. The compact and heavy-duty plastic case is tamper foaming protected, suits 
indoor  and  outdoor  applications.  For  high  reliability  the  Bella  electronic  circuitry  is  sealed 
and protected in separate internal housing. 
This manual is for the Bella I (Siren and Strobe) and Green siren model IPS 
 
Few Bella versions are available: 

Bella I:

 Outdoor cabinet Piezo Siren, LED Strobe light, Dual Tamper switch

 

Bella IPS:

 Outdoor (Power Save) Piezo Siren, LED Strobe light, Dual Tamper switch

 

Bella I AS:

 Same as Bella I plus –STB terminal for separate Strobe trig

 

(Australia & UK)

 

Bella IS:

 Outdoor cabinet Speaker Siren, LED Strobe light, Dual Tamper switch

 

 

Bella  I,  Bella  IPS:  During  alarm  the  siren  and  strobe  light  are  activated  simultaneously 
both at the same time.  

 

Installation Instructions 

 

Step One: Location 

Open  the  front  cover  by  removing  the  screw.  Locate  the  siren  in  a  hard-to-access 
location, as high as possible, away from water and rain sources. 
Use four (4) screws to attach the siren housing to a solid wall. 
 

Step Two: Wiring 

(refer to figure 1 and 2)

 

1. Disconnect DC Power and battery at control panel 
2. The Bella is compatible with most alarm panels, operates with or without battery. 
If  an  EasyLoader  panel  is  connected:  Verify  that  address  072  option  1  (Bell  Mode)  is 
programmed (should be as it’s Factory Default). 
Bella I: Connect the +TRG from Bella to +SIR, the –SIR to –SIR, or apply 12V DC. 
Bella I AS: To activate the strobe apply –V from the SLO output to –STB at the siren. 
To activate the strobe with siren at once connect the –STB to –SIR both at siren. 
 

-SIR 

- DC input to drive the siren. Connect this terminal to the control panel –SIR. 

+TRG 

 

Siren  activated when  apV to this terminal (terminal is referred to –SIR). 
CTRG it to +SIR at the panel. Apply here positive (+12V) to alarm. 

-STB 

Bella I 

AS version only

: Activate the Strobe by applying -V 

TMP 

Tampers contact. Connect to zone input 

TMP 

Tampers contact. Connect to zone common input 

 

3.  Wire  the  Tamper  from  ‘TMP’  two  wires  terminal  to  a  zone  in  the  control  panel. 
Program the Tamper zone as 24H or Tamper type. 

 

Bella is a security device, test operation once a week or more. 

Advise your customer to perform test once a week. 