Motor Adjustment (leveling), Preparation
Lift active
Lift off
Watch the Video on
www.auxx-lift.com/
installation-help
Stop
Do not use PT1
S2 and S3 for
adjustment!
Most important! All switches work the same way, even though their labeling is different.
Before you start to turn the stop (motor limit) switches, please be sure that you are turning them
in the right direction!
STOP
DOWN
UP
1 UP
2 Stop
3 Down
4 Learn
STOP
DOWN
UP
DeadMan off- press key
(up/down) once and the lift
runs. Press STOP 2
This function for
adjustment only!
!Max running Time 1.5min
DL1
(Power)
SW1 S2 S3 PT1
ON
1 2
DL4 DL5 DL7 DL6
LED3 LED2 LED1 DL2 DL3
ON
1 2
Indicator LED
ON
1 2
*
Wire and Motor switch test
*No impact
Motor adjustment
mode,
Deadman off
S2
Remote learn button
S3
Controller running
time learn button
10sec-1.5min
PT1
Delay time Default 5
Lift mode
, DEADMAN active
ADJ DM
Lift activity
Indicator LED
red green green red
Controller Keys
i
Extension stick 3', 1m
Extension stick 3', 1m
With an extension stick you can easy adjust the
motors from the floor!
Maximum Uncoil
13