Auxilab 2600 Manual Download Page 1

ENGLISH

CE DECLARATION OF CONFORMITY

NAHITA CENTRIFUGES of AUXILAB, S.L. for the Directive of Machines (89/392/CEE

modified) and the regulations adopted for their transposition

NAME OF THE MANUFACTURER/IMPORTER:

AUXILAB, S.L.

ADDRESS:

Polígono Morea Norte, 8

31191 Beriáin (Navarra)

WE STATE THAT:

Page 1

Instruction manual 526XXXXX                        Version 2 April-05

AUXILAB S.L.

Are designed and manufactured according to:

Directive 89/392/CEE, including the modifications and the national regulations 
that transpose them.
Directive 89/336/CEE modified over the electromagnetic compatibility.
Directive 73/23/CEE modified over the electric security.
And that the following harmonized rules have been applied (or part of them):

UNE 292-1, UNE 292-2, UNE 292-2/A1, UNE 1050, UNE 614, UNE 1088,
UNE 953, UNE 294, UNE 418, UNE 894-1, UNE 894-2, UNE 954-1, 
UNE981, UNE 60204-1, UNE 61010.

Polígono Morea Norte, 8  31191 Beriain (Navarra) - Spain. Tel. 948 310 513 Fax 948 312 071
Internet: www.auxilab.es · Email: [email protected]

NAHITA CENTRIFUGES SERIES 2690

CODES 52690000 AND 52690050

BERIAIN 7th July 2004

Signed by: ALFONSO AINCIBURU SANZ

DIRECTOR/MANAGER

Š

Š

Š

Revisión 2 de Abril-05

Manual de instrucciones 526XXXXX                Pág. 1

Este manual es parte inseparable del aparato por lo que debe estar dis-
ponible a todos los usuarios del equipo. Le recomendamos leer aten-
tamente el presente manual y seguir rigurosamente los procedimien-
tos de uso para obtener las máximas prestaciones y una mayor dura-
ción del mismo.

This manual should be available for all users of these equipments. To get the
best results and a higher duration of this equipment it is advisable to read
carefully this manual and follow the processes of use.

Ce manuel est une partie  inséparable de l’appareil, c'est pourquoi il
doit  être à la porté de tous les utilisateurs de l'appareil. Nous vous
recommandons de suivre très rigoureusement toutes les  indications
que vous trouverez dans ce  manuel.

CENTRÍFUGAS

CENTRIFUGES

CENTRIFUGEUSES

Analógicas / Analogical / Analogiques

Summary of Contents for 2600

Page 1: ...pain Tel 948 310 513 Fax 948 312 071 Internet www auxilab es Email correo auxilab es NAHITA CENTRIFUGES SERIES 2690 CODES 52690000 AND 52690050 BERIAIN 7th July 2004 Signed by ALFONSO AINCIBURU SANZ DIRECTOR MANAGER Revisión 2 de Abril 05 Manual de instrucciones 526XXXXX Pág 1 Este manual es parte inseparable del aparato por lo que debe estar dis ponible a todos los usuarios del equipo Le recomend...

Page 2: ...ón del equipo por personal no autorizado provocará la pérdida total de la garantía Los fusibles o accesorios así como la pérdida de los mismos no están cubiertos por dicha garantía Tampoco estarán cubiertos por el periodo de garantía las piezas en su des gaste por uso natural Asegúrese de guardar la factura de compra para tener derecho de reclamación o pres tación de la garantía En caso de enviar ...

Page 3: ...R Revisión 2 de Abril 05 Manual de instrucciones 526XXXXX Pág 3 INDICE DE CONTENIDOS 1 APLICACIONES DEL INSTRUMENTO 2 FUNDAMENTOS 3 DESCRIPCIÓN 4 ESPECIFICACIONES TÉCNICAS 5 INSTALACIÓN PUESTA EN MARCHA 6 MANTENIMIENTO Y LIMPIEZA ANEXO I CERTIFICADOS CE 3 3 4 5 5 7 9 INDICE DE IDIOMAS Castellano Inglés Francés 2 11 12 21 22 29 1 APLICACIONES DEL INSTRUMENTO 2 FUNDAMENTOS Centrífugas de diseño comp...

Page 4: ...in symme trical positions If it is necessary we will use tubes filled with water when one of the holes is empty In a centrifuge it is very important the concept of weight then it is advisable to have a balance to adjust the weights of the different tubes This is absolutely necessary since if the rotor is not well balanced it can produce sha kings if these shakings are small it is difficult to noti...

Page 5: ... any value unless you keep a continued and careful maintenance Please follow the processes of use of this manual This manual should be available for all users of this equipment Revisión 2 de Abril 05 Manual de instrucciones 526XXXXX Pág 5 4 ESPECIFICACIONES TÉCNICAS 2600 2610 2615 2650 2655 2690 2690 5 Control Analógico Analógico Analógico Analógico Cabezal Inclinado 45º Inclinado 45º Inclinado 45...

Page 6: ...tion Unwrap the analogical centrifuges take off the involving plastic and take off the polis pan protection in which it comes fitted Take off all the protective items and without con necting the analogical centrifuges to the net make sure that it does not present any dama ge because of the shipment In case the analogical centrifuges present any damage tell it immediately to your transport agent or...

Page 7: ...persona quemaduras heri das y daños a la instalación eléctrica Fabricado según las directivas europeas de seguridad eléctrica compatibilidad electro magnética y seguridad en maquinas Según modelo Desconexión del rotor en caso de apertura Bloqueo de la puesta en marcha estando la tapa abierta 6 MANTENIMIENTO Y LIMPIEZA Para un adecuado funcionamiento de la centrifuga es necesario seguir algunas rec...

Page 8: ... ser limpiados y des infectados con un agente desinfectante Así como reemplazar las piezas rotas Si no se lleva acabo esta operación se producirán daños importantes en los diferentes componentes de la centrífuga así como errores de análisis posteriores debido a la falta de limpieza ATENCIÓN NO SE ADMITIRA NINGUN APARATO PARA REPARAR QUE NO ESTE DEBIDAMENTE LIMPIO Y DESINFECTADO Spanish English Fre...

Page 9: ...of the analo gical centrifuges warranty Neither fuses 1A nor accessories including their loss are covered by the product s warranty The warranty neither covers piece s deterioration due to the course of time Please make sure you keep the invoice either for having the right to claim or asking for warranty coverage In case you have to send the equipment to Nahita Technical Assistance Department you ...

Page 10: ... 2655 REFERENCIA 52655000 BERIAIN a 1 de Abril de 2004 Fdo ALFONSO AINCIBURU SANZ DIRECTOR GERENTE Revisión 2 de Abril 05 Manual de instrucciones 526XXXXX Pág 10 AUXILAB S L Esta diseñado y fabricado de acuerdo a Directiva 89 392 CEE incluidas las modificaciones de la misma y las reglamentaciones nacionales que la trasponen Directiva 89 336 CEE modificada sobre compatibilidad electromagnética Dire...

Reviews: