Except the above parts provided,the other parts needed during installation you must purchase.
ACCESSORIES
NOTE
:
SELECT THE BEST LOCATION
There should not be any heat source or stream
near the unit.
There should not be any obstacles blocking the
air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall,ceiling,fence or other obstacles.
There should not be any direct sunlight. If unavoidable,
sunlight prevention should be taken into consideration.
Indoor unit
Outdoor unit
If an awning is built over the unit to prevent
direct sunsight or rain,be careful that heat
radiation from the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrow from wall
ceiling, fence or other obstacles.
Do not place any obstacles which may cause
a short circuit of the discharged air.
Anchor the outdoor unit with a bolt and nut
φ
10 or
φ
8 tightly and horizontally on a concrete or rigid mount.
Settlement of outdoor unit
NOTE:
The outdoor unit you purchase may be like one
of the following. Install the outdoor unit according to the
dimension as indicated in the table below:
INSTALLATION
15cm
15cm
Above
Above
Above 30cm
A
Left installation feet
Right installation feet
Air inlet
Outdoor Unit
Air outlet
Packing list of the indoor unit
Packing list of the ou tdoor unit
N O.
N ame
Unit
Quantity
1
2
3
4
5
Indo or u nit
Remote control ler
I nstructi ons
Batteries
Dra in pi pe
Set
PC
PC
PC
PC
1
1
1
2
1
N O.
N ame
Unit
Quantity
1
2
3
O utdoor unit
Plastic strap
Set
ROLL
1
1
4
Pipe protection ring
Luting (putty)
PC
PACKE T
1
1
49
A (mm)
B (mm)
Model
(WxDxH)
Outdoor U nit Size of
Shape (mm )
9
12
18
24
800 X 315 X 545
540
730 X 285 X 545
730 X 285 X 545
280
540
280
545
315
900 X 350 X 700
632
352
Summary of Contents for ASW-FH Series
Page 1: ...CL80001 CL80004 INVERTER SERIE FH ASW FH ...
Page 2: ... ES EN 3 34 2 ...
Page 26: ...CONTR OL R EMOTO 26 iFEEL ...
Page 31: ...CONTR OL R EMOTO 31 ...
Page 32: ...CONTR OL R EMOTO 32 ...
Page 33: ...CONTR OL R EMOTO 33 ...
Page 62: ...REMOTE CONTROLLER 62 ...
Page 63: ...REMOTE CONTROLLER 63 ...
Page 65: ...65 ...
Page 66: ...C PROVENZA 392 P2 08025 BARCELONA SPAIN 34 93 446 27 80 ...