Circulation operation mode

 

1) Press  the 

MODE

 button in a sequence until the fan indicator lights up.

2) Press the 

FAN 

button to choose the fan speed (low-med-high)

3) Do not put the duct to the window. 
4) Press the ON/OFF button to start the unit and press it again to stop. 

    

Timer operation 

1) Press the 

TIMER ON

 or

 TIMER OFF

 button to initiate the auto-on or auto-off

    sequence.
2)  Press the 

UP

 or 

DOWN

 button to set your desired wait time. Each press will 

    increase or decrease one hour.  

    

Wind direction adjustment

   

Horizontal airflow (automatic)

   Press the 

SWING 

button, the vertical vanes rotate automatically. If you have 

   a desired direction, you also can press it again to stop at the position.
   

Vertical airflow(manual)

  

 Grab and rotate the middle horizontal vane manually. 

Note:

 

Adjusting the vertical vane by hand in automatically-controlled operation 

          May damage the step-motor. 


 

  

Continuous drainage

 

1) Drain water can be collected externally 
    by directing the plastic tube(inner 
    diameter:12mm~12.5mm) inside the 
    drain tank cabin through the water tank
    to any vessel such a bucket. Remove 
    the plastic tube cap before operating. 
 2.Do not take out the water tank during drainage. 

IMPORTANT: 

This water is not suitable for drinking.

8

Note

: The timer operation in the control panel differs from the remote control.  

   

 Deal with condensation

  

 

Condensation in the water tank

 

 2) Carefully remove the water tank from the cabinet and dispose of the water.

    Replace the water tank back to its original position and the dehumidifying 
    process will automatically resume. It will take 3 minutes for the compressor 
    to restart. This is normal.

1) When the water tank is full, the dehumidification process will immediately 
stop. However the fan motor will continue to operate for two minutes, then 
the LED will display PI and the unit will alarm, at the same time the water 
full indicator light will flash continuously. 

Summary of Contents for AM-12A4

Page 1: ...PORTABLE AIR CONDITIONER INSTRUCTION MANUAL FOR FUTURE REFERENCE Model No AM 12A4 R1 12 000BTU ...

Page 2: ...CONTENTS Introduction 1 Safety Precaution 2 Technical Specifications 4 Parts Description 5 Accessories 6 Operation 7 Installation 9 Maintenance 11 Troubleshooting 12 WEEE Warning 14 ...

Page 3: ... for use in the bedroom study lobby office meeting room ware house attic sports hall and other entertainment rooms Its flexibility enables easy adjustment to a desirable room temperature and humidity The built in filter can remove floating dust and purify air to create a healthy working environment ...

Page 4: ...ey are sharp and may cause an injury Do not clean the air conditioner with water Water may enter the unit and degrade the insulation It may cause an electric Shock When the unit is to be cleaned switch the unit off and unplug it Since the fan rotates at high speed during operation it may cause an injury Do not operate the unit without the air filter or when the front intake grill has been removed ...

Page 5: ...precision devices food pets It could cause dust to accumulate on the heat exchanger This could injure the pets or plants Do not use for special purpose Plants and art objects It may cause deterioration of quality etc Do not apply an insecticide or flammable spray It may cause a fire or deformation of the cabinet 3 ...

Page 6: ...er supply Refrigerant Weight kg Noise dB A Dimension mm 2 Suitable room area m Note The above cooling capacity are calculated at ambient temperature DB 30 WB 25 4 AM 12A4 R1 12000 330 5 2 1200 1PH 220V 240V 50Hz R410a 33 53 378 368 838 14 20 Working temperature range DB Maximum temp Minimum temp 35 18 4 ...

Page 7: ...W Top panel Right panel Front panel Airflow direction vane horizontal Airflow direction vane vertical Control panel Remote controller Cord hanger REAR VIEW LEFT SIDE VIEW Exhaust air outlet Rear panel Air intake condenser Air inlet Air filter inside Left panel Power cord 5 ...

Page 8: ... plug Screw Alkaline batteries Remote controller 1 1 1 4 4 2 1 Cover cover the hole when not in use 1 Control Panel TIMER ON OFF SLEEP COOL DRY FAN LOW MED HIGH MODE WATER FULL FAN SWING UP DOWN ON OFF Mode indicator Fan speed indicator Digital display Timer indicator Signal receiver Water full indicator Sleep indicator 6 ...

Page 9: ...aust hose and the adjustable window slider kit 3 Plug the unit into a 220V 240V socket 4 Make sure the water tank is correctly positioned inside the cabinet otherwise the unit will not operate 5 To turn the unit on press the ON OFF button Cooling operation mode 1 Press the MODE button in a sequence until the cool indicator lights up 2 Press the UP and DOWN button to adjust your desired set tempera...

Page 10: ...tion May damage the step motor Continuous drainage 1 Drain water can be collected externally by directing the plastic tube inner diameter 12mm 12 5mm inside the drain tank cabin through the water tank to any vessel such a bucket Remove the plastic tube cap before operating 2 Do not take out the water tank during drainage IMPORTANT This water is not suitable for drinking 8 Note The timer operation ...

Page 11: ... 5 0 c m Adaptor B Guide of customer The customer should have a qualified power supply coincident with that printed on the tag of the air conditioner Its voltage should be in the range of 90 110 of its rated voltage The customer must use a special circuit and efficient grounding socket to match the plug of the air conditioner If the supply wire is damaged it must be repaired by a qualified electri...

Page 12: ...er to keep the duct length to a minimum 2 Overstretching or bending the duct will affect the cooling efficiency As the following fig Show Do not Amplified view for I Adaptor A Wall plugs Permanent 1 Attach one end of the duct to the exhaust air outlet of the mobile air conditioner According to the arrow direction first fit the left side of the duct on the exhaust air panel then the right side duct...

Page 13: ...the cover Put the filter cover back in its place 5 Plug in the air conditioner or reconnect the power Maintenance Your new air conditioner is designed to give you many years of dependable service This section tells you how to clean and care for your air conditioner properly Call your local authorised dealer for an annual maintenance check Remember the cost of this service call is your responsibili...

Page 14: ...ter in the drain tank Reset the temperature Troubleshooting Air Conditioning will not operate 2 Wipe the unit with a dry cloth 3 If the unit is very dirty wet the cloth with cold water Never use hot water over 40 to clean the air filter Do not use gasoline benzene thinner or any other chemicals or any liquid insecticide on the air conditioner as these substances may cause flaking off of the paint ...

Page 15: ...urned on in hot room The doors or windows are open Set a proper temperature see the methods of application Clean the air filter Remove the obstruction Allow additional time to remove stored heat from walls ceiling floor and furniture Close the doors and windows Causes Solutions Noise or vibration The ground is not level Place the unit on a flat surface 13 ...

Reviews: