7   ›I n I t I a l   s ta R t- u P

1)  With one nearby softened faucet running in the COLD position, slowly open your bypass valve or 3-valve bypass 

to about ¼ open to allow the air trapped in the softener to escape via your running faucet. 

nOTe: Opening the 

bypass too quickly or too open may damage your softener or plumbing

2)  Allow the softener tank to slowly fill with water. After a few minutes, you will see a trickle of water coming from 

the cold water faucet. Allow the water to run slowly in this manner for an additional 5 minutes. Next, with the 
cold water faucet still running, gradually move your bypass valve to the fully open position. 

nOTe: You may see 

some initial discoloration from the softened water – this is normal and should dissipate within the first 

40-50 gallons of water used.

 Turn off the running cold water faucet when the water runs clear

› C o n G R at u l at I o n s

Your new softener with Autotrol 255/760 Valve is now properly installed and programmed! 
Please maintain your system by keeping the softener plugged-in and always keep your brine 
tank filled with salt to at least above the water level. We appreciate your business, and hope 
that you enjoy years of trouble-free softened water!

3) 

 

i                  

To test the integrity of your new system and all connections

,

 it is strongly encouraged that you 

perform a short form regeneration to check for leaks before service. 

Begin this process by adding ap-

proximately 5 gallons of water/the amount of water needed to cover the brine grid into the brine tank. Start the 
regeneration sequence by HOLDING the REGEN button for 5 seconds. Once the hourglass symbol disappears, 
let C1 - Backwash run for about 1 minute to observe the water leave out the drain line and check for leaks. If you 
notice any leaks, 

return to page 8

 to review preparing the drain connection. Simultaneously click the SET and 

UP buttons ONCE to move on to C2 - Regeneration Draw/Slow Rinse

4)  Once the hourglass symbol disappears, let C2 - Regeneration Draw run for about 1 minute to observe the 

water level in the brine tank being drawn lower. Also check the brine line and connections for leaks. If the 
water level doesn't lower or there is a leak

return to pages 9 and 10

 to review preparing the brine tank con-

nection. Simultaneously click the SET and UP buttons until you reach C8 - Regenerant Refill

5)  Once the hourglass symbol disappears, let C8 - Regenerant Refill run for about 1 minute to observe the water 

level in the brine tank rise. Also check the brine line and connections for leaks. If the water level doesn't rise or 
there is a leak, 

return to pages 9 and 10

 to review preparing the brine tank connection. Simultaneously click 

the SET and UP buttons ONCE to finish

6)  Now you may add 120-160 pounds of pellet, solar, or block salt to your brine tank. 

Always keep your brine tank 

filled with salt to at least above the water level. 

You do not need to perform a regeneration immediately after 

installation as the new resin arrives at full softening capacity. Simply let your softener meter automatically trigger 
regenerations by tracking the water consumption

Summary of Contents for 255/760

Page 1: ...v1 0 AUTOTROL 255 760 Metered Water Softener Install ation Guide...

Page 2: ...ming When you first plug in your unit the control will require you to enter the adjacent values Use the UP DOWN buttons to cycle through the settings use the SQUARE SET button to enter edit mode use t...

Page 3: ...lve Page 9 Plumbing the System into your Home and Making the Brine Tank Connection Preface Thank you for your purchase of a new water softener with Autotrol 255 760 Meter Control Valve from QualityWat...

Page 4: ...er by 17 1 to get Grains gpg Ex If your hardness is measured at 300 PPM take 300 17 1 18 gpg before iron 3 Compensated Hardness Your Iron results should also be measured in either PPM or mg L Take you...

Page 5: ...x33 Grid 18x40 Grid 24x41 Grid 24x50 Grid 24K 0 75 cu ft 8x44 0 10 gpg Low 2 25 lbs NO GRID NO GRID NO GRID NO GRID TOO LARGE TOO LARGE 10 20 gpg Standard 6 75 lbs Grid Grid NO GRID NO GRID 20 gpg Hig...

Page 6: ...Fig u r e 6 a Fig u r e 6 b pre install ation Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concr...

Page 7: ...r d fi n e m es h 3 Installing the Autotrol 255 760 Valve 1 Remove the filling funnel and tape and while using the included silicone lubricant packet lubri cate the inner and outer o rings on the bot...

Page 8: ...ow 8 Secure each plumbing adaptor onto the bypass as shown in Figure 8 F i If you are using copper connections first prefabricate and sweat a 12 tube section onto each adaptor and cool BEFORE assembly...

Page 9: ...ording to all local plumbing codes If using copper pipe please pre fabricate at least a 12 section of pipe for the IN and OUT bound lines and use a wet rag on the lines being soldered to prevent heat...

Page 10: ...e tube and insert the tube through the small hole drilled through the brine tank and brine well Loosely un screw the hex nut on the 2310 Brine Float Assem bly Insert the tubing end firmly into the hex...

Page 11: ...UP or DOWN buttons to change to the current time of day i Note that there is a difference between AM and PM Then press the SET button to make this setting active Figure 11 E 6 Next is the Day of the W...

Page 12: ...ess the SET button to begin editing choose L for 0 10 gpg S for 10 20 gpg and H for 20 gpg Use the UP or DOWN buttons to make the appropriate chang es to the salt setting and press the SET button to m...

Page 13: ...lons of water the amount of water needed to cover the brine grid into the brine tank Start the regeneration sequence by HOLDING the REGEN button for 5 seconds Once the hourglass symbol disappears let...

Reviews: