1)  Before beginning your installation, please first 

familiarize yourself with the IN and OUT ports on 
the Autotrol 255/760 Valve. 

In order to prevent 

damage to your home and to the softener 

system, install the softener according to the In 

and OUT arrows on the softener valve

2)  Locate the main shut-off valve for your house 

and turn it to the OFF position. If you have a 
private well, this valve should be near your well 
pressure tank. If you have a city water supply, 
your valve should be near your water meter

3)  Depressurize and drain your home of water by 

turning on all faucets and fixtures in your home, 
including those outside

4)  Pick your installation point and cut a section 

of pipe out to run to and from your softener. 

In most cases it is preferred to keep outside 

lines UnSOfTened. If you wish to keep your 

outside lines unsoftened, you must plumb 

BYPASS lines to run hard water to these fix-

tures

5)  Using soldered copper, PVC plastic pipe, or flex-

ible connections, plumb the system according to 
all local plumbing codes.

 

If using copper pipe, 

please pre-fabricate at least a 12” section 

of pipe for the In and OUT bound lines and 

use a wet rag on the lines being soldered to 

prevent heat damage during soldering

6)  Once all connections have been made, place the 

system into bypass by either using your existing 
3-valve bypass (if ordered with a YOKE adap-
tor), or by switching your included bypass ON (if 
ordered with a bypass)

7)  Next, gradually open your main valve and allow 

all air in your plumbing lines to escape slowly. 
Also, you may turn off all outside and inside 
faucets and fixtures

8)  Check for leaks at your plumbing site for signs 

of slow drips and rectify if necessary. 

Please do 

nOT take the softener out of BYPASS as the 

installation is not completed yet. Please take 

this opportunity to check and re-check the In 

and OUT ports to make sure they are correct

5   › m a k I n G   t H e   B R I n e   ta n k   C o n n eC t I o n

1)  Locate the air check consisting of a clear plastic 

vial with two screws, a rubber ball, and an o-ring. 
First, lay the rubber ball onto the brine port of 
your valve, then lubricate and place the o-ring 
over the port flange as shown in Figure 9-A

2)  Use the two included screws to assemble the 

air check to the valve as shown in Figure 9-B

F I G u R e   9 - a

F I G u R e   9 - B

Summary of Contents for 255/760

Page 1: ...v1 0 AUTOTROL 255 760 Metered Water Softener Install ation Guide...

Page 2: ...ming When you first plug in your unit the control will require you to enter the adjacent values Use the UP DOWN buttons to cycle through the settings use the SQUARE SET button to enter edit mode use t...

Page 3: ...lve Page 9 Plumbing the System into your Home and Making the Brine Tank Connection Preface Thank you for your purchase of a new water softener with Autotrol 255 760 Meter Control Valve from QualityWat...

Page 4: ...er by 17 1 to get Grains gpg Ex If your hardness is measured at 300 PPM take 300 17 1 18 gpg before iron 3 Compensated Hardness Your Iron results should also be measured in either PPM or mg L Take you...

Page 5: ...x33 Grid 18x40 Grid 24x41 Grid 24x50 Grid 24K 0 75 cu ft 8x44 0 10 gpg Low 2 25 lbs NO GRID NO GRID NO GRID NO GRID TOO LARGE TOO LARGE 10 20 gpg Standard 6 75 lbs Grid Grid NO GRID NO GRID 20 gpg Hig...

Page 6: ...Fig u r e 6 a Fig u r e 6 b pre install ation Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concr...

Page 7: ...r d fi n e m es h 3 Installing the Autotrol 255 760 Valve 1 Remove the filling funnel and tape and while using the included silicone lubricant packet lubri cate the inner and outer o rings on the bot...

Page 8: ...ow 8 Secure each plumbing adaptor onto the bypass as shown in Figure 8 F i If you are using copper connections first prefabricate and sweat a 12 tube section onto each adaptor and cool BEFORE assembly...

Page 9: ...ording to all local plumbing codes If using copper pipe please pre fabricate at least a 12 section of pipe for the IN and OUT bound lines and use a wet rag on the lines being soldered to prevent heat...

Page 10: ...e tube and insert the tube through the small hole drilled through the brine tank and brine well Loosely un screw the hex nut on the 2310 Brine Float Assem bly Insert the tubing end firmly into the hex...

Page 11: ...UP or DOWN buttons to change to the current time of day i Note that there is a difference between AM and PM Then press the SET button to make this setting active Figure 11 E 6 Next is the Day of the W...

Page 12: ...ess the SET button to begin editing choose L for 0 10 gpg S for 10 20 gpg and H for 20 gpg Use the UP or DOWN buttons to make the appropriate chang es to the salt setting and press the SET button to m...

Page 13: ...lons of water the amount of water needed to cover the brine grid into the brine tank Start the regeneration sequence by HOLDING the REGEN button for 5 seconds Once the hourglass symbol disappears let...

Reviews: