INTRODUCTION 

Dear Customer! 

Thank You for choosing control panel AUTOTERM Comfort Control! We are doing everything 
to make this product meet Your requirements, so its quality satisfies every customer. 

Comfort  Control  is  designed  to  be  intuitive  and  comfortable  to  use,  to  ensure  the  best 
experience when it comes to controlling Your climate. 

AUTOTERM Comfort Control is compatible with all AUTOTERM AIR and FLOW heaters. 

 

Some older versions of PLANAR heaters may not support some of the functions. 
In case of questions about compatibility with older products please contact Your 
local dealer or AUTOTERM Service center. 

In case of any problems, we strongly recommend to contact certified service centres. Contact 
information  and  location  of  certified  service  centres  can  be  found  at  our  website 

www.autoterm.com

.

 

 

Please read carefully this manual before operating the AUTOTERM heaters. 
This manual contains needful information in order to use this product correctly. 
Disregard  of  these  instructions  can  void  the  warranty  of  the  product,  lead  to 
damage of product and/or property and be a risk to health. 

 

If the heater is handled and/or installed improperly, there is a possibility of a fire 
hazard and damage of property because fuel and electrical components are being 
used. 

That is why all safety precautions, operation and installation instructions 

must be observed.

 

For other languages of this manual, please see 

www.autoterm.com/manuals

. 

 

SAFETY INSTRUCTIONS 

 

Risk to health and/or damage of product 

-

 

The  heater  may  only  be  used  for  the  purposes  specified  in  its  respective  operation 
manual. 

-

 

DO NOT use the heater in closed and/or poorly ventilated places (e.g. garage, workshop, 
etc.) 

-

 

Do not step on the heater or put any objects on it and in it. 

-

 

Do not put any body parts or items in to any of the air inlets or outlets of the heater. 

-

 

For  air  heaters.  Do  not  allow  hot  air  to  be  blown  directly  at  people,  animals  or  heat 
sensitive objects. 

-

 

To avoid burns, do not touch the exhaust lines and the heater while it is operating. 

 

 

 

Summary of Contents for COMFORT CONTROL

Page 1: ...v10 2020 Manufacturer AUTOTERM LLC Paleju 72 Marupe Latvia LV 2167 Warranty Department warranty autoterm com Technical Support service autoterm com www autoterm com COMFORT CONTROL User s manual EN...

Page 2: ...ACK BUTTON 6 1 4 QUICK BUTTON 6 1 5 LED INDICATORS 6 2 MOUNTING AND CONNECTION 7 3 OPERATION AND SETTINGS 8 3 1 MAIN MENU 8 3 2 TIMERS 8 3 3 HEATING 10 3 4 VENTILATION 12 4 SETTINGS 13 4 1 TIME DATE 1...

Page 3: ...eedful information in order to use this product correctly Disregard of these instructions can void the warranty of the product lead to damage of product and or property and be a risk to health If the...

Page 4: ...ust pipe Risk of damage due electrical nature Do not connect disconnect any wiring of the heater while it is connected to the power supply or operating Do not connect the heater to the power circuit o...

Page 5: ...de is cancelled by pressing any button or turning the knob either direction While active display shows o current time o power supply voltage o temperature o set operation mode if active o active timer...

Page 6: ...o start or stop the heater without entering the main menu or quickly enabling or disabling timers While heater is off pressing the button once opens the Heating menu While the heater is off long press...

Page 7: ...e installation degrease the back of the control panel and the desired surface When connected to the power supply control panel turns on automatically When turned on LED indicators light up while showi...

Page 8: ...liquid heaters SETTINGS Is used to change general settings of the control panel and heater 3 2 TIMERS In Timers menu up to 3 timers can be set to start the heater at specific time in desired mode for...

Page 9: ...ay to Friday SEL Select specific day heater starts only on specified days where 1 Monday 3 Wednesday 5 Friday 7 Sunday 2 Tuesday 4 Thursday 6 Saturday Set the operation mode for air heaters Heating mo...

Page 10: ...er without shutting off the combustion process POWER MODE Heater will operate constantly at set power level HEAT VENTILATION Heater will operate till the temperature is reached 1 C above the set tempe...

Page 11: ...temperature and confirm Set work time and confirm When mode is active respective symbol is shown on the main screen Setting Thermostat mode Select Thermostat mode from the menu Set temperature and co...

Page 12: ...coolant temperature is 88 C for Flow 5 and 80 C for Flow 14D Default value for Flow 14D cannot be changed Temperature drop of the coolant is 18 C for Flow 5 and 20 C for Flow 14D Setting Pre heating o...

Page 13: ...irm set value 4 1 TIME DATE Set the current time and date 4 2 DISPLAY LANGUAGE change the display language of the control panel UNITS Change displayed format of units Metric 24h time format C or Imper...

Page 14: ...same information as for air heaters AUXILIARY set and enable disable auxiliary mode When auxiliary mode is enabled pre heater starts when engine starts and maintains set temperature of the coolant Tem...

Page 15: ...tem of the vehicle See installation manual of the heater o COOLANT PUMP enable disable operation modes of the coolant pump WAIT MODE When enabled coolant pump will continue to operate after the heater...

Page 16: ...t pump circuit 14 REMINDER To ensure reliable operation of the heater it is required to start it once in 30 days on max heating power for 30 minutes including the warm seasons of the year when heater...