Unsuccessful 
start

The heater was switched 
off spontaneously at 
startup

Make diagnostics of the heater 
if the error appears again

6

Operation 
cycle too 
short 

The heater was switched 
off spontaneously 

Make diagnostics of the heater 
if the error appears again

8

CAN-bus 
error

There is a problem with 
module connection to the 
CAN-bus

Check for the connection 

9

Settings error Settings have been 

stored in RCP’s memory
incorrectly

Reset the settings (8.1.1), 
readjust the module

11

Heater no 
connection 

The heater is unplugged 
or out of order

Make diagnostics of the heater

Glossary

CAN - Control Area Network (digital network for data transfer in vehicles)
RCP - Remote Control Plug-in (electronic module for the heater remote control)
CIP - Combined Instrument Panel

Summary of Contents for RCP-V5

Page 1: ...Autoplugin RCP V5 Version 7 1 Technical Description User Manual Rev A...

Page 2: ...olvo S90 2016 V90 2016 or XC90 2015 The device controls the heater via CAN bus Module Possibilities Set of inputs for additional remote control connection Set of outputs with programmable heater statu...

Page 3: ...ontrol possibilities See remote control documentation for details Additional Functions By default RCP adjusted to perform only basic functions such as start and stop of the heater from the remote cont...

Page 4: ...eat mode 1 1 1 Not adjusted 1 1 2 40 minutes 1 1 3 50 minutes 1 1 4 60 minutes 1 1 5 70 minutes 1 1 6 80 minutes 1 1 7 90 minutes 1 1 8 100 minutes 1 1 9 120 minutes 1 2 Limitation of heater 1 cycle o...

Page 5: ...er startup 4 1 5 In 25 minutes after heater startup 4 1 6 In 30 minutes after heater startup 4 1 7 In 40 minutes after heater startup 4 1 8 In 50 minutes after heater startup 4 1 9 In 60 minutes after...

Page 6: ...s off potential 7 5 3 Flashers control signal double impulses with the frequency adjusted by 6 7 applying settings 6 3 6 5 3 7 5 4 Engine runs potential 7 5 5 Engine runs RPM impulses 7 5 6 Disable th...

Page 7: ...eater is idle positive impulse given to the input cancels the timer start of the heater programmed in the CIP Table 1 X1 pin number Signal Name Polarity Wire colour 1 Heater_off White 2 Heater_off Gre...

Page 8: ...mpulse X1 4 Heater_on 1 The input can be used to switch the heater on by the impulse of negative polarity the input Heater_on in that case has to be connected to the Power The heater is started by the...

Page 9: ...ntrol if remote is compatible to alerts receiving The assignment of this output is defined by the setting 7 4 When programmed event is occurred the impulse of negative polarity with 1 second duration...

Page 10: ...Appearance Solutions 2 No answer from the heater followed the start command Outer temperature displayed by the CIP is higher than 14 Celsius degrees The heater operates only at temperatures below 15...

Page 11: ...There is a problem with module connection to the CAN bus Check for the connection 9 Settings error Settings have been stored in RCP s memory incorrectly Reset the settings 8 1 1 readjust the module 1...

Page 12: ...12 Autoplugin ES www autoplugin ru...

Reviews: