–The module turns off the heater if battery voltage lowers to the adjusted limit

Troubleshooting

If a run-time error occurs during heater operation, Autoplugin Key informs about 
the error code with embedded LED flashing. The number of flashes corresponds to 
the error code. See table 2 for the errors description and possible solutions.

Table 2

Error 
Code

Error 

Description

Possible Reasons of 

Error Appearance

Solutions

2

No answer 
from the 
heater 
followed the 
start 
command

Outer temperature 
displayed in CIP is 
higher than +14 Celsius 
degrees

The heater operates only at
temperatures below +15°C. It 
is heater manufacturer
restriction

Fuel level in the fuel 
tank is close to empty 
(“Fuel Low” warning 
indicator is illuminated
in the CIP)

Refuel the car

The heater is blocked 
after several
unsuccessful starts

Try to start the heater in the 
CIP menu. If it doesn’t start
up, make diagnostics of the 
heater.

3

Battery low

The module has 
determined that the
battery voltage is below 
the specified by settings 
items 3.1 or 3.2

Charge car’s battery with 
special charger (or start engine 
to charge) or cancel 3.1/3.2 
module’s settings

4

Time limits 
exceeded 

Time limit for 
autonomous operation of 
the heater is achieved

Run the engine or cancel 1.1 
module’s settings

5

Unsuccessful 
start

The heater was switched 
off spontaneously at 
starting

Make diagnostics of the heater 
if the error appears again

6

Operation 
cycle too 
short 

The heater was switched 
off spontaneously 

Make diagnostics of the heater 
if the error appears again

Summary of Contents for Key-V3

Page 1: ...Autoplugin Key V3 Version 9 6 User Manual Rev B...

Page 2: ...ssibilities 3 Package Content 3 Connection 3 Basic Functions 4 Additional Functions 4 Troubleshooting 7 Glossary CAN Control Area Network digital network for data transfer in vehicles CIP Combined Ins...

Page 3: ...ditional main battery protection from discharging by inspecting of voltage level and time of heater autonomous operation Package Content 1 Autoplugin Key V3 cartridge 2 User Manual brochure Connection...

Page 4: ...ter Setup mode and to change the settings It is necessary to stop the engine and the heater before Switch the ignition on turn the key to the position II then press and hold the brakes pedal Rotate th...

Page 5: ...r total operational time in pre heat mode 1 1 1 Not adjusted 1 1 2 40 minutes 1 1 3 50 minutes 1 1 4 60 minutes 1 1 5 70 minutes 1 1 6 80 minutes 1 1 7 90 minutes 1 1 8 100 minutes 1 1 9 120 minutes 1...

Page 6: ...dicators in rearview mirrors 6 1 Indication of heater startup 6 1 1 Off 6 1 2 Five flashes 6 2 Indication of command reception from a remote control 6 2 1 Off 6 2 2 Three flashes 6 3 Indication of hea...

Page 7: ...It is heater manufacturer restriction Fuel level in the fuel tank is close to empty Fuel Low warning indicator is illuminated in the CIP Refuel the car The heater is blocked after several unsuccessful...

Page 8: ...ed in module s memory incorrectly Reset the settings 8 1 1 readjust the module 11 Heater no connection The heater is unplugged or out of order Make diagnostics of the heater The device is powered from...

Reviews: