Autoplugin GSM Kit-V2 Installation Manual Download Page 7

7

1.1.8

   100 minutes

1.1.9

   120 minutes

1.2.

Limitation of the 

heater’s cycle 
operational time, in 
pre-heat mode 

1.2.1  

10 minutes

1.2.2  

15 minutes

1.2.3  

20 minutes

1.2.4  

25 minutes

1.2.5  

30 minutes

1.2.6  

40 minutes

1.2.7  

50 minutes

1.2.8  

60 minutes

1.2.9  *

70 minutes

2.

Heater 
Control by 
Volvo Key

2.1. 

“Lock” and 

“Lamp” button’s
functions for the 
heater control

2.1.1

  *”Lock” button to the heater startup, 

yellow button to the heater stop  

2.1.2

  “Lamp” button to the heater startup, 

“Lock” button to the heater stop

2.2.

Number of 

sequential turning on 
and then turning off 
the perimeter lighting 
by “Lamp” button for 
the heater control

2.2.1  

Heater control by “Lamp” button 

disabled 

2.2.2  *

Two times

2.2.3  

Three times

2.2.4  

Four times

2.3.

Number of 

sequential “Lock” 
button presses for the 
heater control (with 
the perimeter lighting 
turned on)

2.3.1  

Heater control by “Lock” button 

disabled 

2.3.2  *

Two presses

2.3.3  

Three presses

2.3.4  

Four presses

3. 

Battery
Monitoring

3.1.

Minimal voltage to let 
the heater start in pre-
heat mode 

3.1.1

   * Not adjusted

3.1.2

   11.8V 

3.1.3

   11.8V 

3.1.4

   11.9V 

3.1.5

   

12.0V

3.1.6

   12.1V

3.1.7

   12.2V

3.1.8

   12.3V

3.1.9

   12.4V

3.2.

Minimal voltage to 
keep operating the 
heater for pre-heat 
mode

2

3.2.1

   * Not adjusted

3.2.2

   11.4V

3.2.3

   11.5V 

3.2.4

   11.6V 

3.2.5

   

11.7V

3.2.6

   11.8V

3.2.7

   11.9V

3.2.8

   12.0V

Summary of Contents for GSM Kit-V2

Page 1: ...Autoplugin Therminal V2 Version 7 5 Technical Description Installation Manual Rev A...

Page 2: ...e GSM module receives commands from user s phone or smartphone and sends them to the RCP module which controls the heater via CAN bus Possibilities Start and stop of the heater by SMS or via specializ...

Page 3: ...S timer send the stop command by remote control for the idle heater DIS timers will be temporary disabled Start the heater by any way or turn the ignition on will enable DIS timers again 5 An addition...

Page 4: ...dules together Only highlighted at the figure 2 connectors are used Take Plug n Play cable and connect it to interconnection cable Find a place inside the dashboard for modules RCP and GSM modules can...

Page 5: ...les inside the dashboard with straps If modules are placed separately RCP module can be fixed with adhesive tape and GSM module can be fixed with straps Pay attention that internal antenna of GSM modu...

Page 6: ...ode the right turn to the second digit of code To confirm a digit entering press and release Read button DIS will flash one time by the both repeaters simultaneously After the third digit will be ente...

Page 7: ...rning off the perimeter lighting by Lamp button for the heater control 2 2 1 Heater control by Lamp button disabled 2 2 2 Two times 2 2 3 Three times 2 2 4 Four times 2 3 Number of sequential Lock but...

Page 8: ...art 6 4 1 Off 6 4 2 On 6 5 Indication of operated heater started by additional button 6 5 1 Off 6 5 2 On 6 7 Flashing frequency for the indication of heater autonomous operation 6 7 1 One flash within...

Page 9: ...lutions 1 Wrong heater configuration The heater is not activated in DIS Configure the heater by Volvo car dealer equipment Outer temperature is upper than 15 Celsius degrees The heater works only with...

Page 10: ...een LED can be connected to the GSM module to control its status in the case of permanent connection If Plug n Play cable is used for connection green status LED of GSM module is placed inside the hou...

Page 11: ...ation System of the instrument cluster GSM Global System for Mobile GPRS General packet radio service packet oriented mobile data service LED Light Emission Diode RCP Remote Control Plug in electronic...

Page 12: ...12 Autoplugin ES www autoplugin ru...