3.3.d TEST Button (Diagnostic Menu)
Follow the instructions listed below to get accurate results.
1. If the unit is in the Boost mode, take the unit out of Boost mode.
2. Power the system off at the power breaker switch. Wait three (3) minutes for unit to completely
discharge any remaining electricity to the cells.
3. Power on the unit and put back into the Boost mode or increase the Purifier to 100% output. Let the
unit run for three (3) minutes.
4. Press TEST to initiate the test sequence. Record diagnostics information, including cell Amps and
Volts, for each cell.
5. Deactivate Boost mode and return purifier output % to the original setting.
The unit will automatically sequence through various displays and then return to normal
operation. You can also press the
△
or
▽
arrow to scroll forwards and backwards. Press the
MENU/ENTER button again to skip the remaining displays and exit back to normal operation.
l
Software Ver. X.x – Current version of the control board display software
l
Power Setting – High/Low (Factory default is Low)
l
Alarm – Enabled/Disabled (Factory default is Enabled)
l
Reverse – # hrs. –The reverse rate programmed in the Installation Menu (Factory default is 4 hrs)
l
Salt – ### ppm (#.# g/L)” – The Tri-sensor salt reading. The optimum salt level is 3,500 ppm (mg/L),
4,500 ppm (mg/L) for efficient chlorine production
l
Add ## Salt (lbs.) – (Amount needed to maintain 3,000 ppm (mg/L)
l
Water Temperature ##° F (##° C) – The temperature of the water flowing through the Tri-sensor
l
Pool Volume - gallons (litres) –The pool volume programmed in the Installation Menu
l
Cell x - ##V – Cell number and volts to the cell measured for each cell connected
l
##### Amp-Hrs, and then
l
SW Ver: - #.##
l
RS232 Enabled/Disabled - Factory use only and set to Enabled
l
ATC Enabled/Disabled - Automatic Temperature Compensation feature.
Compensation" on page 8. Enabled is the factory default and cannot be changed
3.3.e WARNING Light and Audible Alarm
The WARNING light will flash to warn the unit may need attention. A warning message will also
be displayed. If enabled, an audible alarm may also be heard when the system light is flashing.
Unless deemed a normal condition per below, refer to the "
Troubleshooting
" section.
l
Flashes red when pump is off / water flow is insufficient
l
Flashes when salt is low (check salt and add as needed)
l
Flashes when water temperature exceeds 125 °F (51 °C), or drops below 10 °F (-12 °C)
3.4 Normal Display Modes
Purifier Mode
Purifier (Chlorine Output %) level..................... Shown in 1% increments
Water Temperature
Displayed in Fahrenheit or Celsius
Salt Level
Pool / spa water salt concentration level..................... Shown in ppm (mg/L)
WARNING! Light
Off when operating normally. The Warning light will blink red when an error has occurred, such
as for insufficient flow and low salt levels. See "Troubleshooting" on page 31.
Summary of Contents for Pool Pilot Professional PPP-2
Page 2: ......