background image

PROA / PROB Manual 

9/24/19 

PRO WC 

PROA & PROB Water Cooled Series 

Swimming Pool Purification System 

Owner’s Manual: Installation / Operation and Maintenance 

This manual covers the installation and operation of the AutoPilot

®

 PRO WC Chlorine 

Generators  

Important! 

Read this manual and product labels before installing or operating this equipment. 
This document is Purchaser’s property and is to remain with the equipment owner. 

LTP0155 

Summary of Contents for Pool Pilot PROA PROB Series

Page 1: ...nstallation Operation and Maintenance This manual covers the installation and operation of the AutoPilot PRO WC Chlorine Generators Important Read this manual and product labels before installing or o...

Page 2: ...PROA PROB Manual 9 24 19...

Page 3: ...llation Diagram 12 2 7 Power Supply Installation 13 2 8 Electrolytic Cell Installation 13 2 9 Install Kit Installation 14 2 10 Plumbing the System 15 2 11 Plumbing the Power Supply Cooling Lines 15 2...

Page 4: ...PROA PROB Manual 9 24 19...

Page 5: ...If you have questions please refer to our website for the latest manual revisions additional information and helpful service advice Web www AutoPilot com Power Supply Serial Phone 727 823 5642 8 5 pm...

Page 6: ...ite is then circulated to the pool and combines with organics and further combines to form salt to be used again by the electrolytic cell This is called a closed loop system because the salt is used r...

Page 7: ...pa 20 gpm 4 54 m3 h 1 in 2 5 cm 1 in 2 5 cm PROB22 22 lbs day 9 98 kg 100 50 psi 345 kpa 20 gpm 4 54 m3 h 1 1 2 in 3 8 cm 1 1 2 in 3 8 cm PROB28 28 lbs day 12 7 kg 100 50 psi 345 kpa 20 gpm 4 54 m3 h...

Page 8: ...ents PROA8 11 14 PROB17 PROB22 PROB28 11 27 6 Cell Tube Cooling Water Lines DC Power to Cell 22 Cooling Water Lines DC Power to Cell 26 22 26 66 cm 6 15 2 cm 11 28 cm 15 38 6 cm Sensors AC Input Senso...

Page 9: ...0 00 0 02 0 04 0 06 0 08 0 10 0 12 0 14 0 16 Sizing Guidelines Chlorinator sizing must comply with all state and local codes Please contact your local health department for specific requirements or c...

Page 10: ...d take any additional safety measures appropriate Be extremely careful in the presence of hazardous substances The personnel responsible for installation operation and maintenance of this equipment mu...

Page 11: ...The system has the potential to release high doses of chorine Use caution when handling servicing or operating the equipment Do not energize or operate the system if the cell housing is damaged or imp...

Page 12: ...PROA PROB Manual Page 12 of 28 9 24 19 2 6 INSTALLATION DIAGRAM Rated See Table...

Page 13: ...t will accommodate the dimensions of the system The power supply brackets should be mounted to a solid wall surface or wall stud Failure to mount the power supply properly may result in the dislodging...

Page 14: ...ed in the installation kit are available Follow the diagram below when positioning the parts provided in the installation kit NOTE The flow switch must be installed with the arrow facing the bottom of...

Page 15: ...ent in the return line of the pool after all other equipment See the plumbing diagram below 2 11 PLUMBING THE POWER SUPPLY COOLING LINES The power supply cooling lines are plumbed from the return line...

Page 16: ...ver operates when the pool pumps are off RISK OF ELECTRICAL SHOCK For ease of service it is recommended that a manual disconnect box be installed between the electrical service and the system Follow t...

Page 17: ...d relay box to the wall close enough to the power supply so that the patch cord will connect to the FEED SALT connector on the power supply Plug the relay box into a 120 VAC outlet Plug the peristalti...

Page 18: ...AquaCal AutoPilot Inc for a list of approved salt Your pool water should be balanced in the following range before turning your AutoPilot PRO WC system on Chlorine 2 5 ppm Total Chlorine No more than...

Page 19: ...C systems connected to a chemical feed controller will only operate when the controller is in feed mode Make sure that the chemical feed controller is not set in proportional mode or system damage may...

Page 20: ...creen is displayed if a low salt condition is present Salt concentration below 3 000 ppm will stop the system output and display this screen When the salt concentration is raised above 3 000 ppm norma...

Page 21: ...HOCK Disconnect all AC power when installing or servicing this system RISK OF ELECTRICAL SHOCK All electrical connections should be made by a licensed electrician or certified electrical contractor RI...

Page 22: ...the salt concentration of the pool with the addition of an external relay see saturated salt feeder system The factory set point for salt is 5 000 ppm The salt set point can be adjusted to any value...

Page 23: ...ion Salt must be maintained at 3 500 to 5000 ppm Check salt as often as necessary to ensure the concentration Adjust the salt concentration as often as needed to maintain the desired level Test the fl...

Page 24: ...intained NIOSH approved respirator for acid fumes 1 To clean the cell manually disconnect power from the system close the lower cell isolation valve and then close the upper cell isolation valve 2 Unp...

Page 25: ...burned wires loose connections or corrosion Operate the system to verify performance once every month 1 Turn the system on 2 Adjust the control knob to the full off position and note that the amps dis...

Page 26: ...to the cleaning frequency program AutoPilot warranties of the titanium electrodes will not be honored if the system is operated in water temperatures lower than 59 F During the warranty period the cu...

Page 27: ...___ Tel _____________________ Installation site of equipment ___________________________________________ Address _________________________________City __________________ State ______________________Zi...

Page 28: ...PROA PROB Manual Page 28 of 28 9 24 19 www aquacal com www autopilot com AquaCal AutoPilot Inc 2737 24th Street North St Petersburg FL 33713 727 823 5642...