background image

Message

‐  ‐  ‐  ‐

Lost

 

communication

 

between

 

the

 

power

 

center

 

and

 

the

 

generator

 

cell

Check

 

the

 

cell

 

cord

 

connection

 

at

 

the

 

power

 

center

 

for

 

damage

 

to

 

the

 

wire.

2.

 

Transformer

 

wiring

 

is

 

incorrect,

 

check

 

it

 

is

 

wired

 

properly

 

for

 

incoming

 

voltage.

 

3.

 

Fuse

 

(10A)

 

may

 

have

 

failed,

 

test

 

and

 

replace

 

if

 

necessary.

4.

 

Transformer

 

or

 

Power

 

Center

 

circuit

 

board

 

has

 

failed,

 

replace

 

the

 

Power

 

Center.

 

(p/n:

 

ECP0312)

Add

 

Salt

 

to

 

achieve

 

3,500

 

ppm

 

(mg/L).

Lo

 

SALt

1.

 

No

 

power

 

to

 

the

 

Power

 

Center,

 

check

 

breaker.

 

If

 

unit

 

is

 

wired

 

to

 

a

 

time

 

clock,

 

make

 

sure

 

it

 

is

 

turned

 

on.

                                                                             

No

 

Display

No

 

Display

 

/

 

Blank

 

Display

Alternating:

                   

Output/24

 

hr.

 

countdown

Alternating

 

Display

Normal

 

operation,

 

unit

 

is

 

in

 

BOOST

 

mode.

 

Press

 

and

 

hold

 

both

 

the

 

Up

 

Arrow

 

and

 

Down

 

Arrow

 

simutaneously

 

to

 

activate/deactivate

 

BOOST

 

MODE.

DISPLAY

 

MESSAGES

 

&

 

TROUBLESHOOTING

Problem

OPEn

 

CELL

 

Err

Cell

 

blades

 

are

 

receiving

 

no

 

current

Check

 

for

 

loose

 

or

 

damaged

 

wiring,

 

inspect

 

cell

 

for

 

damage.

NO

 

FLO

Insufficient

 

water

 

flow

1.

 

Check

 

pump

 

for

 

proper

 

operation

 

and

 

service

 

as

 

necessary.

                          

2.

 

Check

 

filter:

 

clean/service

 

as

 

necessary.

                                                            

3.

 

Check

 

system

 

valve

 

settings

 

for

 

proper

 

flow

 

to

 

the

 

unit.

                                 

4.

 

Check

 

for

 

obstruction

 

in

 

the

 

cell

 

(debris

 

or

 

scaling

 

accumulation).

                

5.

 

Flow

 

sensor

 

may

 

need

 

to

 

be

 

serviced

 

or

 

replaced.

 

Contact

 

a

 

local

 

Service

 

Center

 

for

 

assistance.

CLn

 

CELL

Cell

 

may

 

be

 

scaled

High

 

volts

 

are

 

going

 

to

 

the

 

cell.

 

Check

 

cell

 

for

 

scale,

 

clean

 

as

 

necessary

 

and

 

balance

 

water.

Add

 

SALt

Solution

Salt

 

level

 

is

 

2,300

 ‐ 

2,700

 

ppm

 

(mg/L)

Salt

 

level

 

is

 

below

 

2,300

 

ppm

 

(mg/L)

Add

 

Salt

 

to

 

achieve

 

3,500

 

ppm

 

(mg/L).

CLn

 

CELL

 

SOOn

The

 

voltage

 

at

 

the

 

cell

 

is

 

26

 

to

 

28

 

VDC.

 

Chlorine

 

is

 

still

 

being

 

generated.

  

The

 

cell

 

may

 

be

 

dirty

 

or

 

have

 

calcium

 

build

 

up.

 

Inspect

 

and

 

clean

 

the

 

cell

 

as

 

needed.

HIgH

 

Curr

 

Err

High

 

Voltage

 

or

 

Over

 

Current

 

has

 

been

 

detected

 

and

 

the

 

system

 

is

 

locked.

Possible

 

undissolved

 

salt

 

brushed

 

into

 

the

 

main

 

drain.

 

The

 

salt

 

will

 

need

 

to

 

dissolve

 

for

 

this

 

condition

 

to

 

normalize.

 

The

 

system

 

will

 

automatically

 

recheck

 

in

 

one

 

hour

 

increments

 

to

 

see

 

if

 

this

 

condition

 

persists.

 

If

 

the

 

condition

 

persists,

 

the

 

system

 

will

 

lock

 

with

 

a

 

high

 

current

 

error

 

fault.

 

A

 

power

 

reset

 

will

 

be

 

required

 

to

 

clear

 

this

 

fault.

SEnS

 

Err

A

 

temperature

 

sensor

 

error

 

has

 

been

 

detected.

 

Contact

 

a

 

local

 

Service

 

Center

 

for

 

assistance.

SHrt

 

CELL

 

Err

Low

 

voltage

 

or

 

a

 

short

 

circuit

 

has

 

been

 

detected.

 

Chlorine

 

generation

 

is

 

halted.

 

If

 

the

 

voltage

 

remains

 

low,

 

the

 

system

 

will

 

automatically

 

re

test

 

for

 

1

 

hour.

 

If

 

the

 

issue

 

persists,

 

contact

 

a

 

local

 

Service

 

Center

 

for

 

assistance.

RS

485

 

Data

 

(+)

 ‐

Terminal

 

A

RS

485

 

Data

 

(

)

 ‐

Terminal

 

B

Black wire

 

from

 

PoolSync® to

 

GND

Yellow

 

wire

 

from

 

PoolSync®

 

to

 

A

Green

 

wire

 

from

 

PoolSync®

 

to

 

B

Red

 

wire

 

from

 

PoolSync®

 

to

 

VDC

Pool

 

cover

 

Switch

 

(dry

 

contacts)

RS

485

 

Data

 

(+)

 ‐

Terminal

 

A

RS

485

 

Data

 

(

)

 ‐

Terminal

 

B

Connect

 

only

 

one

 

red

 

wire

 

for

 

PoolSync.

 

If

 

using

 

PoolSync

 

on

 

additional

 

devices,

 

leave

 

red

 

wire

 

off

 

on

 

those

 

additional

 

devices.

LTM1034