Message
‐ ‐ ‐ ‐
Lost
communication
between
the
power
center
and
the
generator
cell
Check
the
cell
cord
connection
at
the
power
center
for
damage
to
the
wire.
2.
Transformer
wiring
is
incorrect,
check
it
is
wired
properly
for
incoming
voltage.
3.
Fuse
(10A)
may
have
failed,
test
and
replace
if
necessary.
4.
Transformer
or
Power
Center
circuit
board
has
failed,
replace
the
Power
Center.
(p/n:
ECP0312)
Add
Salt
to
achieve
3,500
ppm
(mg/L).
Lo
SALt
1.
No
power
to
the
Power
Center,
check
breaker.
If
unit
is
wired
to
a
time
clock,
make
sure
it
is
turned
on.
No
Display
No
Display
/
Blank
Display
Alternating:
Output/24
hr.
countdown
Alternating
Display
Normal
operation,
unit
is
in
BOOST
mode.
Press
and
hold
both
the
Up
Arrow
and
Down
Arrow
simutaneously
to
activate/deactivate
BOOST
MODE.
DISPLAY
MESSAGES
&
TROUBLESHOOTING
Problem
OPEn
CELL
Err
Cell
blades
are
receiving
no
current
Check
for
loose
or
damaged
wiring,
inspect
cell
for
damage.
NO
FLO
Insufficient
water
flow
1.
Check
pump
for
proper
operation
and
service
as
necessary.
2.
Check
filter:
clean/service
as
necessary.
3.
Check
system
valve
settings
for
proper
flow
to
the
unit.
4.
Check
for
obstruction
in
the
cell
(debris
or
scaling
accumulation).
5.
Flow
sensor
may
need
to
be
serviced
or
replaced.
Contact
a
local
Service
Center
for
assistance.
CLn
CELL
Cell
may
be
scaled
High
volts
are
going
to
the
cell.
Check
cell
for
scale,
clean
as
necessary
and
balance
water.
Add
SALt
Solution
Salt
level
is
2,300
‐
2,700
ppm
(mg/L)
Salt
level
is
below
2,300
ppm
(mg/L)
Add
Salt
to
achieve
3,500
ppm
(mg/L).
CLn
CELL
SOOn
The
voltage
at
the
cell
is
26
to
28
VDC.
Chlorine
is
still
being
generated.
The
cell
may
be
dirty
or
have
calcium
build
up.
Inspect
and
clean
the
cell
as
needed.
HIgH
Curr
Err
High
Voltage
or
Over
Current
has
been
detected
and
the
system
is
locked.
Possible
undissolved
salt
brushed
into
the
main
drain.
The
salt
will
need
to
dissolve
for
this
condition
to
normalize.
The
system
will
automatically
recheck
in
one
hour
increments
to
see
if
this
condition
persists.
If
the
condition
persists,
the
system
will
lock
with
a
high
current
error
fault.
A
power
reset
will
be
required
to
clear
this
fault.
SEnS
Err
A
temperature
sensor
error
has
been
detected.
Contact
a
local
Service
Center
for
assistance.
SHrt
CELL
Err
Low
voltage
or
a
short
circuit
has
been
detected.
Chlorine
generation
is
halted.
If
the
voltage
remains
low,
the
system
will
automatically
re
‐
test
for
1
hour.
If
the
issue
persists,
contact
a
local
Service
Center
for
assistance.
RS
‐
485
Data
(+)
‐
Terminal
A
RS
‐
485
Data
(
‐
)
‐
Terminal
B
Black wire
from
PoolSync® to
GND
Yellow
wire
from
PoolSync®
to
A
Green
wire
from
PoolSync®
to
B
Red
wire
from
PoolSync®
to
VDC
Pool
cover
Switch
(dry
contacts)
RS
‐
485
Data
(+)
‐
Terminal
A
RS
‐
485
Data
(
‐
)
‐
Terminal
B
Connect
only
one
red
wire
for
PoolSync.
If
using
PoolSync
on
additional
devices,
leave
red
wire
off
on
those
additional
devices.
LTM1034
2
of
2