Page 10 APCG4
Q & A
The grow area is getting too humid or hot?
Remove the left
burner and replace with the supplied pipe plug. This will
reduce heat and humidity.
Should the APCG4 be buzzing and / or sparking?
Yes,
when the unit is firing you will hear “sparking” sounds. It will
attempt this up to 5 times, before going into lock out mode.
However it is not usual for the unit not to start after 5 times
unless the gas flow has been interrupted.
The indicator light beside the “Lock Out (error)” is
flashing.
The unit may be out of propane or the gas supply
may have been interrupted. The safety mode or Lock Out
(error) is an automatic built-in feature that will activate if the
pilot does not fire after 5 attempts. Once the problem has been
corrected, turning the power off for 30 seconds and back on
will reset this function. It will also reset after 20 minutes and
attempt to ignite the burners.
How should the flame(s) appear?
The flames should burn
clean and blue with a resemblance to a flower or 6 point star.
If the flame is yellow, extra large or a small blue dot not
resembling a flower or 6 point star, DO NOT OPERATE THE
GENERATOR… consult the factory
Does it matter which burner I remove?
Yes, the burner on
the right located directly under the igniter must remain in
place.
How much CO2 does the unit produce?
The brass burners
are designed to produce approximately 3 cu ft per hr. If more
CO2 production is required, select a CO2 generator with more
burners.