LM 706 A/C Service Station

11

B

Remove the blue low-pressure refrigerant pipe from the equipment and the high-pressure

quick coupling from the red high-pressure pipe.

C

Use red high-pressure pipe to short-circuit the high-pressure and low-pressure interfaces.

D

Run it and will stop automatically.

3.11.2.7 Release air

When the pressure in the equipment tank is higher than the normal standard pressure (refer to the temperature and
pressure comparison table on the side of the equipment), it is necessary to exhaust.
When there is a high pressure alarm, the pressure will be released automatically.
In order to prolong the service life of the equipment, it is recommended to exhaust once a month.

3.11.2.8

Info & inquiry

System inquiry: you can query the equipment usage.
Servicer info: inquire about the phone number of the service provider.
Equipment infor: query equipment serial number, software and hardware version and other information.

3.11.2.9

Change vacuum pump oil

A

When the pump oil became cream or the unit displays maintenance message, the vacuum

pump oil must be changed.

B

If not change the pump oil, the vacuum function will not be able to run.

C

Steps:

Step1: open the back cover.

Step2: Unscrew the block of the drain port to drain entirely out the old oil. Then re-back the

block to the drain port.

Step3: Unscrew the cap of the fill port and then fill the new oil slowly into the vacuum pump

until the oil level reach at the center site. Then re-back the cap to the fill port.

Note: the new vacuum pump oil cannot be filled too much into the vacuum pump
otherwise it will spray out when working.

Window

Drain port

Fill port

Summary of Contents for LM 706

Page 1: ...LM 706 A C Service Station LM 706 A C Service Station...

Page 2: ...ts such as cooling fans alternators and heating components etc to avoid harm Wear protective clothing gloves and goggles As automotive air conditioning pipe flushing the operator must be fully familia...

Page 3: ...3 6 Vacuum 5 3 7 Fill new oil 5 3 8 Recharging 6 3 9 Auto Mode 7 3 10 Database 7 3 11 Auxiliary functions 8 3 11 1 Usage of the Auxiliary Port 8 3 11 2 System functions 8 3 11 2 1 Parameter setting 8...

Page 4: ...with the gas or the liquid C Touch button improved control performance long service life D Designed with large size LCD E Database F USB update port program and database can be updated G Equipped with...

Page 5: ...Vacuum C Fill new oil D Recharging E Auto Mode 2 2 Subsidiary functions A Database B Parameter setting C Calibration professional D Supply main tank E Maintenance procedures dry filter exchange vacuu...

Page 6: ...Open the back door take out all the fillers on both sides of the cylinder and under the scale pan so that the scale pan is suspended B Set language select and press OK HP gauge Operation panel LP gau...

Page 7: ...gerants at least 2kg F Please read this user manual carefully before operating 3 3 Preparations before Operation A Connect the red blue couplers to the HP LP ports of automobile air conditioner respec...

Page 8: ...or with the front and rear wind C Operations Note after the operation of the equipment there is no need for personnel to take care of it until it is finished by itself D If it displays code as W durin...

Page 9: ...the equipment stops automatically Note in the process of new oil filling do not take the oil bottle and shake the equipment otherwise it will lead to inaccurate filling 3 8 Recharging Through this fu...

Page 10: ...plete the recharging process Later you should supply new refrigerant into the tank 3 9 Auto Mode A Under this mode all of the functions can be run full automatically after setting the parameters B Bef...

Page 11: ...back the cap to the auxiliary port Tip when using the external tank to fill the refrigerant it may be necessary to start the car and turn on the air conditioner in some cases It is forbidden to conne...

Page 12: ...igerant of the equipment is less than 2kg it need to be supplemented If the refrigerant is less than 1kg the filling function will not be performed B Operations B 1 Select Supply main tank function B...

Page 13: ...ollowed by letter SN D Please attention the mounting direction of the dry filter 3 11 2 5 Drain used oil Normally the equipment will automatically drain the used oil after flushing and or recovery fun...

Page 14: ...ry System inquiry you can query the equipment usage Servicer info inquire about the phone number of the service provider Equipment infor query equipment serial number software and hardware version and...

Page 15: ...l clean and ventilated place h The maintenance items indicated by the equipment should be done in time i When the equipment is not in use for a long time or when it is loaded and transferred to anothe...

Reviews: