background image

DUAL INDICATOR TEMPERATURE CONTROLLER

TS4 SERIES

I N S T R U C T I O N   M A N U A L

(unit: mm)

 

RSA-COVER(48×48mm)

 

RMA-COVER(72×72mm)

 

RHA-COVER(48×96mm)

 

RLA-COVER(96×96mm )

 

Terminal cover(sold separately

)

 Bracket

  TS4-M Series

  TS4-C, TS4-H, TS4-B Series

 Panel cut-out

 Size

Series

A

B

C

D

T

S

4

-M

Min. 65

Min. 65

45

0.6

  0

45

0.6

  0

T

S

4

-C

Min. 90

Min. 90

68

0.7

  0

68

0.7

  0

T

S

4

-

H

Min. 65

Min. 115 45

0.6

  0

92

0.8

  0

T

S

4

-B

Min. 115 Min. 115 92

0.8

  0

92

0.8

  0

A

C

D

B

  TS4-M Series

45

64.5

6

  TS4-C Series

64.5

67.5

6

  TS4-H Series

91.5

64.5

6

  TS4-B Series

91.5

64.5

6

46

23.9

12

37.5 40.5

3.3

4

  TS4M -  -P

44.8

56

1.7

11.5

6

31

55

56

20

15

21

5

45

16

48.6

44.9

36

70

68.5

3

64

13

48.4

9.8

41.5

18

22

22.5

91.5

86

4

13

47.2

91.5

86

3

13

94

 Ordering Information

 Specificatio

 Dimensions

 Unit Description

 Input Sensor and Temperature Range

R

Relay c SSR drive output

2

2

24VAC 50/60Hz, 24-48VDC

4

100-240VAC 50/60Hz

2

 Alarm2 output

M

DIN W48 × H48mm

C

DIN W72 × H72mm

H

DIN W48 × H96mm

B

DIN W96 × H96mm

4

9999 (4 digit)

S

Dual display type, set by touch switch

T

Temperature controller

Item

Setting type

Digit

Size

Sub output

Power supply

Control output

Series

TS4-M

TS4-C

TS4-H

TS4-B

Power

supply

AC Power

100-240VAC

 50/60Hz

AC/DC Power 24VAC

 50/60Hz, 24-48VDC

Allowable voltage range 90 to 110% of rated voltage

Power 
consumption

AC Power

Max. 5VA(100-240VAC 50/60Hz)

AC/DC Power Max. 5V(24VAC 50/60Hz), Max. 3W(24-48VDC) 

Display method

7 segment (PV: red, SV: green), other display part(green, red) LED method

Character

size

PV(W×H)

7.0×15.0mm

9.5×20.0mm

7.0×14.6mm

11.0×22.0mm

SV(W×H)

5.0×9.5mm

7.5×15.0mm

6.0×12.0mm

7.0×14.0mm

Input

type

RTD

DIN Pt100Ω, Cu50Ω (Allowable line resistance max.5Ω per a wire)

TC

K(CA), J(IC), L(IC), T(CC), R(PR), S(PR)

Display

accuracy 

1

RTD

At room temperature(23ºC ± 5ºC): (PV ± 0.5% or ±1ºC, select the higher one) ± 1 digit

 

Out of room temperature range: (PV± 0.5% or ±2ºC, select the higher one)± 1digit

 

For 

  

T

M

4S-

   

-P, add ±1

 by accuracy standard.

TC

Control

output

Relay

250VAC

 3A 1a

SSR

12VDC

±2V 20mA Max. 

Alarm output

AL1, AL2 Relay: 250VAC

 1A 1a

Control method

ON/OFF control, P, PI, PD, PID control

Hysteresis

1 to 100

/

℉ (

0.1 to 50.0

/

℉)

Proportional band(P)

0.1 to 999.9ºC/

Integral time(I)

0 to 9999 sec.

Derivative time(D)

0 to 9999 sec.

Control period(T)

0.5 to 120.0 sec.

Manual reset

0.0 to 100.0%

Sampling period

100ms

Dielectric

strength

AC power

2000VAC 50/60Hz 1min.(between input terminal and power terminal)

AC/DC power 1000VAC 50/60Hz 1min.(between input terminal and power terminal)

Vibration

0.75mm amplitude at frequency of 5 to 55Hz in each X, Y, Z direction for 2 hours

Relay life

cycle

Mechanical OUT: Over 5,000,000 times,  AL1/2: Over 5,000,000 times 
Electrical

OUT: Over 200,000 times(250VAC 3A resistive load)

AL1/2: Over 300,000 times(250VAC 1A resistive load)

Insulation resistance

Min. 100MΩ(at 500VDC megger)

Noise 

Square-wave noise by noise simulator(pulse width 1

)  ±2KV R-phase and S-phase

Memory retention

Approx. 10 years (when using non-volatile semiconductor memory type)

Environ

-ment

Ambient temp.  -10 to 50ºC, Storage: -20 to 60ºC 
Ambient humi. 35 to 85%RH, Storage: 35 to 85%RH

Insulation type

Double insulation or reinforced insulation (mark:  , dielectric strength between 

the measuring input part and the power part : AC power 2kV, AC/DC power 1kV)

Approval
Weight 

2

Approx. 147g

(approx. 100g)

Approx. 203g

(approx. 133g)

Approx. 194g

(approx. 124g)

Approx. 275g

(approx. 179g)

1:   At room temperature(23ºC±5ºC)

-  Below 200ºC of thermocouple R(PR), S(PR) is (PV ±0.5% or ±3ºC, select the higher one) ±1 digit

-  Over 200ºC of thermocouple R(PR), S(PR) is (PV ±0.5% or ±2ºC, select the higher one) ±1 digit 

-

Termocouple L (IC), RTD Cu50Ω is (PV ±0.5% or ±2ºC, select the higher one) ±1 digit

 

  

Out of room temperature range

-  Below 200ºC of thermocouple R(PR), S(PR) is (PV ±1.0% or ±6ºC, select the higher one) ±1 digit

-  Over 200ºC of thermocouple R(PR), S(PR) is (PV ±0.5% or ±5ºC, select the higher one) ±1 digit 

-

Thermocouple L(IC), RTD Cu50Ω is (PV ±0.5% or ±3ºC, select the higher one) ±1 digit 

For 

 

T

S

4

M

-

     

-P, add ±1

 by accuracy standard. 

2: The weight includes packaging. The weight in parentheses is for unit only. 

 Environment resistance is rated at no freezing or condensation.

1

3

4
5

6

2
7

8

1. Present temperature (PV) display (Red)

1) RUN mode: Present temperature (PV) display

2) Parameter setting mode: Parameter display

2. Set temperature (SV) display (Green)

1) RUN mode: Set temperature (SV) display

2)  Parameter setting mode 

: Parameter setting value display

3. Control/Alarm output display indicator

1) OUT:  It turns ON when the control output is ON. 

During SSR drive output type in CYCLE/

PHASE control, this indicator turns ON when 

MV is over 3.0%. 

2) AL1/AL2: It turns ON when the alarm output is ON.

4. Auto tuning indicator

AT indicator flashes by every 1 sec during operating 

auto tuning.

 

5. 

 key

Used when entering into parameter groups, 

returning to RUN mode, moving parameter, and saving

setting values.

Input sensor

Display

Temperature range(

ºC

) Temperature range(

)

Thermocouple

K(CA)

KCaH

-50 to 1200

-58 to 2192

KCaL

-50.0 to 999.9

-58.0 to 999.9 

J(IC)

JIcH

-30 to 800

-22 to 1472

JIcL

-30.0 to 800.0

-22.0 to 999.9

L(IC)

LIcH

-40 to 800

-40 to 1472

LIcL

-40.0 to 800.0

-40 to 999.9

T(CC)

TCcH

-50 to 400

-58 to 752

TCcL

-50.0 to 400.0

-58.0 to 752.0

R(PR)

RPR

0 to 1700

32 to 3092

S(PR)

SPR

0 to 1700

32 to 3092

RTD

DPt100Ω

DPtH

-100 to 400

-148 to 752

DPtL

-100.0 to 400.0

-148.0 to 752.0

Cu50Ω

CUsH

-50 to 200

-58 to 392

CUsL

-50.0 to 200.0

-58.0 to 392.0

 Parameter Groups

 Press 

 key over 3 sec in any parameter group, it saves the set value and returns to RUN mode.

   (Exception: Press 

 key once in SV setting group, it returns to RUN mode).

  If no key entered for 30 sec., it returns to RUN mode automatically and the set value of parameter 
is not be saved. 

  Press  

key again within 1 sec. after returning to RUN mode, it advances of the first parameter 

of previous parameter group. 
 Press 

 key to move next parameter. 

 Parameter marked in 

 might not be displayed depending on other parameter settings. 

  Set parameter as 'Parameter 2 group → Parameter 1 group → Setting group of set value' order  

considering parameter relation of each setting group. 
1: It is not displayed for AC/DC power model (

  

T

S

4

 

 

-22R).

Run mode

PAR1

IN-Tㅑㅑ

MAvF  

PAR2

SV setting

Parameter 1group

Parameter 2group

AL1

AL1 alarm termerature

AL2 alarm termerature

Input

sensor

UNIT

Temperature

unit

IN-Bㅑㅑ

Input

correction

Input 

digital filter

L-SV  

SV low-limit 

value

H-SV  

SV high-

limit value

O-FT

Control output 

operation

C-MD

Control type

OUT

Control output 

type

SSrM

SSR drive output 

method

1

T

Control

cycle

AL-1

AL1 alarm

operation mode

AL-2

AL2 alarm

operation mode

AHYS

Alarm output 

hysteresis

LBaT

LBA

monitoring time

LBaㅑㅑB

LBA detection 

band

DI-K

Digital input 

key

ErMV

Control output  MV in case

of input break error

LOC

Parameter 

lock

AL2

AT

Auto tunung

P

Proportional band

I

Integral time

D

Derivative time 

REST

Manual reset

HYS

Hysteresis

Please any key among

,  ,  , 

1. All Parameter

No-mark

Bolt wiring method

P

Connector plug connection method

1

Wiring method

1: 

Only for T

S

4

-M

 model.

 

2:

  In case of the AC voltage model, SSR drive output method (standard ON/OFF control, cycle 

 control, phase control) is available to select. 

6. Adjustment

 Used when entering into set value change mode, digit moving and digit up/down. 

7. Digital input key

 Press       keys for 3 sec. to operate the set function 

 (RUN/STOP, alarm output reset, auto tuning) in digital input key [

DI-T

]. 

8. Temperature unit (

ºC

/

) indicator

It shows current temperature unit. 

TCN4S-

 

-P

2sec.

4sec.

3sec.

3sec.

 The above specifications are subject to change and some models may be discontinued

without notice.

※ 

Be sure to follow cautions written in the instruction manual and the technical descriptions 

(catalog, homepage).

AL1 OUT

250VAC

1A 1a
AL2 OUT

250VAC

1A 1a

B'

RTD

B
A

Relay OUT

250VAC

3A 1a

SSR

OUT

1

SOURCE

2

TC

Thank you for choosing our product.

Please read the following safety considerations before use.

 Safety Considerations

Please observe all safety considerations for safe and proper product operation to avoid hazards.

Safety considerations are categorized as follows.

Warning

 Failure to follow these instructions may result in serious injury or death.

Caution 

Failure to follow these instructions may result in personal injury or product damage.

The symbols used on the product and instruction manual represent the following

 symbol represents caution due to special circumstances in which hazards may occur. 

Warning

 

Caution

T   S    4  M    2  4  R  P

1.  Fail-safe device must be installed when using the unit with machinery that may cause 

serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, 

ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster 

prevention devices, etc.)

Failure to follow this instruction may result in fire, personal injury, or economic loss.

2.  Install on a device panel to use.

Failure to follow this instruction may result in electric shock or fire.

3.  Do not connect, repair, or inspect the unit while connected to a power source.

 

Failure to follow this instruction may result in electric shock or fire.

4.  Check 'Connections' before wiring.

Failure to follow this instruction may result in fire.

5.  Do not disassemble or modify the unit.

Failure to follow this instruction may result in electric shock or fire.

1.   When connecting the power input and relay output, use AWG 20(0.50mm

2

) cable or over and 

tighten the terminal screw with a tightening torque of 0.74~0.90N.m. 

When connecting the sensor input and communication cable without dedicated cable, use 

AWG 28~16 cable and tighten the terminal screw with a tightening torque of 0.74~0.90N.m.

Failure to follow this instruction may result in fire or malfunction due to contact failure.

2.  Use the unit within the rated specifications

Failure to follow this instruction may result in fire or product damage. 

3.  Use dry cloth to clean the unit, and do not use water or organic solvent. 

Failure to follow this instruction may result in electric shock or fire.

4.  Do not use the unit in the place where flammable/explosive/corrosive gas, humidit , direct 

sunlight, radiant heat, vibration, impact, or salinity may be present.

Failure to follow this instruction may result in fire or explosion.

5.  Keep metal chip, dust, and wire residue from flowing into the unit

Failure to follow this instruction may result in fire or product damage.

<Crimp terminal>

a

b

c

Terminal 

number

a

b

c

1 to 8

6

Max. 1.7 Max. 3.7

9 to 11 6 to 8 Max. 2.1 Max. 4.2

12 to 14 6 to 8 Max. 1.5 Max. 3.5

T

S

4 Series has selectable control output; Relay output, and 

SSR drive output. AC/DC voltage type does not have SSRP 

function.

1: 12VDC±2V 20mA Max.

2:  AC voltage type: 100-240VAC 5VA 50/60Hz

AC/DC voltage type:  24VAC 5VA 50/60Hz 

24-

48VDC 3W

Use crimp terminals or teminals of size specified below.

 (unit: mm) 

a b

<Round>

a b

<Forked>

a

Min. 3.0

Min. 3.0

b

Max.5.8

Max.5.8

 Connections

 

T

S

4

-

M

1

6

2

7

3

8

4

9

5

11

13

SSROUT:

12VDC±2V

20mAMax.

SOURCE:

100-240VAC

5VA50/60

,

RTD TC B'

SENSOR

AL

M2

OUT:

250VAC1A1a
AL

M1

OUT:

250VAC1A1a

RelayOUT:

250VAC3A1a

B

A

10

 TS4

-C

SSROUT:

12VDC±2V

20

Max.

1

SOURCE:

100-240VAC

5VA50/60

,

24VAC5VA50/60

,

24-48VDC3W

B'

 

RTD

 

TC

SENSOR

AL1OUT:

250VAC

1A1a

AL2OUT:

250VAC

1A1a

B

A

1
2

3

4

5

6
7

8
9

10

11

12
13

14

 

T

S

4

-

H/

B

SSROUT:

12VDC±2V

20

Max.

1

SOURCE:

100-240VAC

5VA50/60

,

24VAC5VA50/60

,

24-48VDC3W

B' RTD TC

SENSOR

AL1OUT:

250VAC

1A1a

AL2OUT:

250VAC

1A1a

RelayOUT:

250VAC3A

1a

B

A

1
2
3

4

5

6

7

8
9

10
11

12
13

14

RelayOUT:

250VAC3A

1a

 

48

 

48

 

72

48

96

 

96

Reviews: