background image

-|Transparent Guide|-

Product Components

• 

Product × 1

• 

Instruction manual × 1

• 

Cable gland × 1

Sold Separately

• 

Mounting bracket: BK-SFEN

• 

Holding key: SFEN-HK

Cautions during Use

• 

Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.

• 

Use the switch with the dedicated controller. Do not use the switch with another controller 
randomly.

• 

Durability of the product can be differed according to opening condition. 

 

Check the environment where the product is used in and machine which the product is used 
for, and use the product within the rated number of mechanical durability.

• 

Do not connect a load with a small capacity to the contact point that has opened and closed 
the load once. 

 

It may cause product malfunction due to the rough contact surface.

• 

If the contact is not opened and closed for a long time, the contact resistance may increase or 
conduction failure may occur due to oxidation of the contact surface or etc. 

• 

This product is dedicated for Autonics safety door switch, SFD Series. 

 

Do not use with the door lock switch from other manufacturer.

• 

To unlock the stop button, turn the button approximately 45°clockwise, and do not turn the 
button with excessive force. 

• 

Do not hit or flip the switch or button, and use hand not any tool to push the switch or button.

• 

This unit may be used in the following environments.

 

- Indoors (UL Type 1 Enclosure)

 

- Altitude max. 2,000 m

 

- Pollution degree 3

 

- Installation category II

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. 

Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or product damage.

02. 

Keep the product away from metal chip, dust, and wire residue which might flow 

into the unit.

Failure to follow this instruction may result in fire, product damage or malfunction. 

03.  Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire.

04.  Do not use the switch as a door lock, guard door stopper or for stopping/starting 

machinery.

Failure to follow this instruction may result in product damage.

05. 

When combining the cover, if the rubber packing is twisted, lifted, cracked, 

broken, or foreign substances are introduced, the sealing properties and operation 

characteristics may be deteriorated.

Be careful not to be damaged by sharp objects and use it after confirming that it is properly 

combined.

06.  Use only Autonics holding key.

Failure to follow this instruction may result in product damage.

07. 

Do not apply excessive vibration or shock to the switch in the status of the switch 

with the holding key insurted into the door switch.

Failure to follow this instruction may result in product damage or malfunction.

08.  Do not use metallic cable gland.

Failure to follow this instruction may result in electric shock due to the damage on the 

service entrance.

09. 

When the SFEN-B is used alone, it cannot be used as a stop button switch. 

Be sure to use it together with the stop button switch or emergency cut-off switch installed 

in a fixed position.

Since it is a separatly using product, it cannot satisfy the SEMI-S2 standard.

10.  In SFEN-M, when  A and B push buttons are pressed at the same time, both 

contacts are in the ON status. 

Please use it after confirming that there are no safety problems. 

Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.  

SFEN -

❶ Type

No mark: Standard type

B: Stop button type

M: Momentary button type

Specifications

• Enable switch

Rated Insulation 

Voltage

250 VACᜠ

Rated through current

2.5 A

Rated inductive load

AC-15 (0.75 A / 240 VACᜠ), DC-13 (0.55 A / 125 VDCᜡ)

Rated resistive load

 01)

0.75 A / 240 VACᜠ, 0.55 A / 125 VDCᜡ

Controller strength

 02)

Operation direction: 200 N, for 1 min

Operating frequency

Electrical: ≤ 20 / min, Machanical: ≤ 20 / min

Dielectric strength

Between terminals of same polarity, between terminals of different polarity, 

between terminal and non-live part

: 2,500 VACᜠ 50 / 60 Hz for 1 min (impulse dielectric strenght)

Electrical life cycle

≥ 100,000 operations (rated load)

Machanical life cycle

OFF → ON → OFF: ≥ 100,000 opertions / OFF → ON: ≥ 1,000,000 operations

 01)  Use a 10 A fuse gl or gG conforming to IEC60269 as short-circuit protection. The body does not have a built-in 

fuse.

 02)  Do not use the switch more than the controller strength. Failure to follow this instruction may result in 

product damage.

• Stop button

Rated Insulation 

Voltage

250 VACᜠ

Rated through current

3 A

Rated resistive load

 01)

AC-12 (3 A / 250 VACᜠ), DC-12 (3 A / 30 VDCᜡ)

Controller strength

 02)

Operation direction: 400 N, for 1 min (operation direction: 0.5 N m, for 1 min)

Operating frequency

Electrical: ≤ 10 / min, Machanical: ≤ 10 / min

Dielectric strength

Between terminals of same polarity: 1,000 VACᜠ 50 / 60 Hz for 1 min.

between terminals of different polarity, between terminal and non-live part

: 2,000 VACᜠ 50 / 60 Hz for 1 min.

Electrical life cycle

≥ 100,000 operations (rated load) (Push / Release 1 time)

Mechanical life cycle

≥ 100,000 operations (Push / Release 1 time)

 01)  Use a 10 A fuse gl or gG conforming to IEC60269 as short-circuit protection. The body does not have a built-in 

fuse.

 02)  Do not use the button more than the controller strength. Failure to follow this instruction may result in 

product damage.

• Momentary button

Rated Insulation 

Voltage

125 VACᜠ

Rated through current

0.1 A

Rated resistive load

 01)

AC-12 (0.1 A / 125 VACᜠ), DC-12 (0.1 A / 30 VDCᜡ)

Controller strength

 02)

Operation direction: 10 N, for 1 min

Operating frequency

Electrical: ≤ 25 / min, Machanical: ≤ 60 / min

Dielectric strength

Between terminals of same polarity: 600 VACᜠ 50 / 60 Hz for 1 min.

between terminals of different polarity, between terminal and non-live part

: 1,000 VACᜠ 50 / 60 Hz for 1 min.

Electrical life cycle

≥ 100,000 operations (rated load)

Machanical life cycle

≥ 1,000,000 operations

 01)  Use a 10 A fuse gl or gG conforming to IEC60269 as short-circuit protection. The body does not have a built-in 

fuse.

 02)  Do not use the button more than the controller strength. Failure to follow this instruction may result in 

product damage.

  

Common spec.

Conditional short circuit 

current

100 A 

Min. applied load

DC24 V 4 mA

Directing opening force

30 N ± 10

Directing opening 

distance

4.8 mm ± 0.5

Insulation resistance

≥ 100 MΩ (500 VDCᜡ megger)

Vibration (malfunction)

1.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, 

Z direction for 10 min

Shock (malfunction)

150 m/s² (≈ 15 G) in each X, Y, Z direction for 3 times

Ambient temperature

-10 to 55 ℃, storage: -25 to 65 ℃ (no freezing or condensation)

Ambient humidity

35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)

Insulation class

Class ll (double insulation)

Indicator

Enable operation indicator (green)

Protection structure

SFEN: IP66 (IEC standard)

SFEN-B, SFEN-M: IP65 (IEC standard)

Applicable wire

AWG 20 to 18 (0.5 to 0.75 mm

2

)

Connection type

M20 connector cable grand

Meterial

Cover: PA66, button: PC, rubber grip: Silicone

International standards

IEC 60947-5-1, IEC 60947-5-8, UL 60947-5-1

Approval

 ᜨ ᜪ 

GB/T14048.5

 

Unit weight (package)

SFEN: ≈ 238 g (≈ 363 g)

SFEN-B: ≈ 268 g (≈ 388 g)

SFEN-M: ≈ 252 g (≈ 376 g)

  

Contact composition

SFEN

SFEN-B

SFEN-M

Enable switch

2 N.O.

2 N.O.

2 N.O.

Option output

1 N.C.

-

-

Stop button

-

2 N.C.

-

Momentary button

-

-

2 N.O.