• SOURCE: 100 - 240 VACᜠ 50 / 60 Hz 9 VA
24 VACᜠ 50 / 60 Hz 6.5 VA, 24 - 48 VDCᜡ 5 W
■ Cautions during Wiring
■
Indicator
•
Unit: mm, Use terminals of size specified
below.
≥3.5
≤7.0
INA
+12V
INB
0V
8
1
10
3
12
5
9
2
11
4
13
6
14
7
15
17
16
SOURCE
HOLD /
RESET
■ Relay single output
■ Relay double output
INA
+12 V
CONTACT OUT:
250 VACᜠ 3 A, 30 VDCᜡ 3 A
RESISTIVE LOAD
INB
0 V
HIGH
8
1
10
3
12
5
9
2
11
4
13
6
14
7
15
17
16
SOURCE
HOLD /
RESET
INA
H
L
+12V
CONTACT OUT:
250 VACᜠ 3 A, 30 VDCᜡ 3 A
RESISTIVE LOAD
INB
0V
HIGH
LOW
8
1
10
3
12
5
9
2
11
4
13
6
14
7
15
17
16
SOURCE
HOLD /
RESET
Dimensions
•
Unit: mm, For the detailed drawings, follow the Autonics website.
14.3
11.8
75
□67.5
□72
■
Bracket
■ Panel cut-out
46
4
5
37.5 40.5
≥ 91
□68
+ 0.7
0
≥ 91
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
MP 5 M
- ❶ ❷
❶ Power supply
2: 24 VACᜠ 50 / 60 Hz, 24 - 48 VDCᜡ
4: 100 - 240 VACᜠ 50 / 60 Hz
❷ Output
N: Indicator
1: Relay single (high-limit) +
NPN open collector output
2: Relay double (high / low-limit) +
NPN open collector output
Mode Setting
RUN
[MODE]
→
Parameter 0
group
[MODE]
→
RUN
[MODE] 2 sec
→
Parameter
group
01)
[MODE] 3 sec
→
01) Press [▲], [◀] key or [MODE] key for 1.5 sec after entering parameter: select parameter groups.
Parameter Setting
•
Some parameters are activated / deactivated depending on the model or setting of
other parameters. Refer to the description of each parameter.
•
The parameter and setting value are cross-displayed on the display part.
•
If any key is not entered for 60 sec in each parameter, it returns to RUN mode.
•
[MODE] key: Saves current setting value and moves to the next parameter.
[◀] key: Checks fixed value / Changes setting digits.
[▲], [◀] key: Changes setting values.
■
Parameter 0
group
Parameter
Display
Default
Setting range
Display
condition
P0-1
Max.
monitoring
value
hPEK 99999
• Reset (PV): [◀] key for over 2 sec
P1-1 Input
op
e
ration
mode:
except F11,
F14
P0-2
Min.
monitoring
value
lPEK `9999
Op
eration mode
Measurement range
Measurement accuracy
(23 ± 5 ℃)
F1
Frequency / revolutions / speed 0.0005 Hz to 50 kHz
F.S. ± 0.05 % rdg ± 1-digit
F2
Passing speed
F3
Cycle
0.01 to max. of each time range F.S. ± 0.01 % rdg ± 1-digit
F4
Passing time
F5
Time interval
F6
Time differential
F7
Ab
solute ratio
0.0005 Hz to 50 kHz
F.S. ± 0.05 % rdg ± 1-digit
F8
Density
F9
Length measurement
1
0 to 99999
-
F10
Interval
F11
Accumulation
F12
Addition / subtraction
-
individual input
-19999 to 99999
F13
Addition / subtraction
-
phase
difference input
F14
Length measurement 2
0 to 99999
Specifications
Series
MP5M-□N
MP5M-□1
MP5M-□2
Input signal
01)
Solid state input 1: ≤ 50 kHz (pulse width: ≥ 10 ㎲)
Solid state input 2
02)
: ≤ 5 kHz (pulse width: ≥ 100 ㎲)
Contact input: ≤ 45 Hz (contact: ≥ 12 VDCᜡ 5 mA, pulse width: ≥ 11 ms)
Voltage input
Input impedance: 3.9 kΩ, [H]: 4.5 - 24 VDCᜡ, [L]: 0 - 1 VDCᜡ
No-voltage input
Short-circuit impedance: ≤ 80 Ω, residual voltage: ≤ 1 VDCᜡ,
open-circuit impedance: ≥ 100 kΩ
Display method
7-segment LED (zero blanking method)
Character size
W 4 × H 8 mm
Prescale
0.0001 × 10
-9
to 9.9999 × 10
9
Hysteresis
-
0 to 9999
03)
Display cycle
OFF
04)
, 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle)
Display range
-19999 to 99999
Contact control output
Relay
Type
-
1c × 1
1a × 2
Capacity
-
250 VACᜠ 3 A, 30 VDCᜡ
3 A resistive load
250 VACᜠ 3 A, 30 VDCᜡ
3 A resistive load
Solid-state control output
NPN open collector
Type
-
× 1
× 2
Capacity
-
≤ 30 VDCᜡ 100 mA
≤ 30 VDCᜡ 100 mA
Approval
ᜢ ᜧ ᜫ
Unit weigth (package)
≈ 168 g (≈ 243 g)
≈ 181g (≈ 256g)
≈ 190 g ( ≈ 265 g)
01) Standard duty ratio 1:1
02) Operation mode F7, F8: ≤ 1 kHz (pulse width: ≥ 500 ㎲)
03) The hysteresis setting range varies according to the decimal point setting position.
04) Only available operation mode F2, F14
AC voltage
AC / DC voltage
Power supply
100 - 240 VACᜠ ᜠ ± 10 %
50 / 60 Hz
24 VACᜠ ± 10 % 50 / 60 Hz,
24 - 48 VDCᜡ ± 10 %
Power consumption
≤ 9 VA
AC: ≤ 6.5 VA, DC: ≤ 5 W
External power supply
≤ 12 VDCᜡ ±10 % 80 mA
Memory retention
Number of inputs: 100,000 operations (non-volatile semiconductor memory type)
Relay life cycle
Mechanical: ≥ 5,000,000 operations
Electrical: ≥ 100,000 operations (250 VACᜠ 3 A resistive load)
Insulation resistance
≥ 100 MΩ (500 VDCᜡ megger)
Dielectric strength
2,000 VACᜠ 60 Hz for 1 min
Noise immunity
± 2 kV the square wave noise (pulse width: 1㎲) by the noise simulator
Vibration
0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z
direction for 1 hour
Vibration
(malfunction)
0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z
direction for 10 min
Shock
300m / s² (≈ 30G) in each X, Y, Z direction for 3 times
Shock (malfunction)
100m / s² (≈ 30G) in each X, Y, Z direction for 3 times
Ambient temperature
-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humidity
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)