background image

 

 

 

 

© Copyright Reserved Autonics Co., Ltd. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for MP Series

Page 1: ... Copyright Reserved Autonics Co Ltd i ...

Page 2: ...ii Copyright Reserved Autonics Co Ltd ...

Page 3: ...ng an Autonics product Please familiarize yourself with the information contained in the Safety Precautions section before using this product This user manual contains information about the product and its proper use and should be kept in a place where it will be easy to access ...

Page 4: ...or reproduced in either part or whole without permission A user manual is not provided as part of the product package Visit our web site www autonics com to download a copy The manual s content may vary depending on changes to the product s software and other unforeseen developments within Autonics and is subject to change without prior notice Upgrade notice is provided through out homepage We con...

Page 5: ...Communication Protocol Copyright Reserved Autonics Co Ltd v Communication Protocol MP5 Series is accepted to Modbus RTU Protocol Users should be aware that it does not support a broadcast command ...

Page 6: ...ls Symbol Description Supplementary information for a particular feature Failure to follow instructions can result in serious injury or death Failure to follow instructions can lead to a minor injury or product damage An example of the concerned feature s use 1 Annotation mark ...

Page 7: ...electric shock or fire Check Connections before wiring Failure to follow this instruction may result in fire Do not disassemble or modify the unit Failure to follow this instruction may result in electric shock or fire When connecting the power measurement input and relay output use AWG 24 0 20mm 2 to AWG 15 1 65mm 2 cable and tighten the terminal screw with a tightening torque of 0 98 to 1 18N m ...

Page 8: ...Safety Precautions viii Copyright Reserved Autonics Co Ltd ...

Page 9: ...04 04H 14 1 5 Force single coil Func 05 05H 15 1 6 Preset single registers Func 06 06H 16 1 7 Preset multiple registers Func 16 10H 17 1 8 Exception response error code 18 2 Modbus Mapping Table 19 2 1 Read coil status Func 01 Force single coil Func 05 19 2 2 Read input status Func 02 19 2 3 Read input registers Func 04 19 2 4 Read holding registers Func03 Preset single registers Func 06 Preset mu...

Page 10: ...Table of Contents x Copyright Reserved Autonics Co Ltd ...

Page 11: ...Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte If read the 10 output status ON 1 OFF 0 within coil 000001 0000 H to 000010 0009 H on Slave Address 17 from Master Query Master Slave address Function Starting address No of points Error check CRC16 High Low High Low Low High 11 H 01 H 00 H 00 H 00 H 0A H H H If the values range from coil 000008 0007 H to 000001 0000 H on the Slave are ON ON OFF OFF ON ON O...

Page 12: ...Byte 1Byte 1Byte 1Byte 1Byte If read the 10 input status ON 1 OFF 0 within range 100001 0000 H to 100010 0009 H in the Slave Address 17 from the Master Query Master Slave address Function Starting address No of points Error check CRC16 High Low High Low Low High 11 H 02 H 00 H 00 H 00 H 0A H H H If the values range 100008 0007 H to 100001 0000 H on Slave are ON ON OFF OFF ON ON OFF ON and the valu...

Page 13: ...RC16 High Low High Low High Low Low High 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte If read the 2 values from Holding Register 400001 0000 H to 400002 0001 H in Slave Address 17 from the Master Query Master Slave address Function Starting address No of points Error check CRC16 High Low High Low Low High 11 H 03 H 00 H 00 H 00 H 02 H H H If the value of 400001 0000 H on Slave...

Page 14: ...gh Low High Low High Low Low High 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte If read the 2 values within the range from Input Register 300001 0000 H to 300002 0001 H on Slave Address 17 from Master Query Master Slave address Function Starting address No of points Error check CRC16 High Low High Low Low High 11 H 04 H 00 H 00 H 00 H 02 H H H If the values of 300001 0000 H and...

Page 15: ...e 1Byte 2 Response Slave Slave address Function Starting address Preset data Error check CRC16 High Low High Low Low High 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte If Coil 000001 0000 H turns ON of Slave Address 17 from Master Query Master Slave address Function Starting address Preset data Error check CRC16 High Low High Low Low High 11 H 05 H 00 H 00 H FFH 00 H H H Response Slave Slave add...

Page 16: ...Response Slave Slave address Function Starting address Preset data Error check CRC16 High Low High Low Low High 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte If write 10 A H to Holding Register 40001 0000 H on Slave Address 17 from Master Query Master Slave address Function Starting address Preset data Error check CRC16 High Low High Low Low High 11 H 06 H 00 H 00 H 00 H 0A H H H Response Slave ...

Page 17: ...10 A H in common to the range of Holding Register 400001 0000 H to 400002 0001 H on Slave Address 17 from Master Query Master Slave address Function Starting Address No of register Byte count Data Data Error check CRC16 High Low High Low High Low High Low Low High 11 H 10 H 00 H 00 H 00 H 02 H 04 H 00 H 0A H 00 H 0A H H H Response Slave Slave address Function Starting address No of register Error ...

Page 18: ...queried data is inconsistent with transmittable address from the device ILLEGAL DATA VALUE Exception Code 03 H Numbers of queried data are inconsistent with the numbers of transmittable transferable data from the device SLAVE DEVICE FAILURE Exception Code 04 H Not properly completed the queried command order Read the output status of non existing coil 010001 03E8 H ON 1 OFF 0 on Slave Address 17 f...

Page 19: ...RESET input status 100002 0001 02 R BANK BANK input status 100003 0002 02 R 0 OFF 1 ON 100004 0003 02 R 0 OFF 1 ON 100005 0004 02 R 0 OFF 1 ON 100006 0005 02 R 0 OFF 1 ON 100007 0008 02 R 0 OFF 1 ON 100008 0007 02 R 0 OFF 1 ON 100009 0008 02 R 0 OFF 1 ON 100010 0009 02 R 0 OFF 1 ON 100011 000A 02 R 0 OFF 1 ON 100012 to 100050 02 R 0 OFF 1 ON 2 3 Read input registers Func 04 No Address Func R W Par...

Page 20: ...00126 to 300200 04 R Reserved No Address Func R W Parameter Description Setting range Note 301001 03E8 04 R HH Front Display LED HH LED Display 0 OFF 1 ON 0 bit H H LED Display 0 OFF 1 ON 1 bit GO GO LED Display 0 OFF 1 ON 2 bit L L LED Display 0 OFF 1 ON 3 bit LL LL LED Display 0 OFF 1 ON 4 bit 301002 03E9 04 R PV Measurement value 19999 to 99999 301003 03EA 301004 03EB 04 R DOT 0 00000 1 000 0 2...

Page 21: ... to 400050 03 06 16 R W Reserved 1 In operation modes F8 F10 F14 F15 the setting range is 19999 to 99999 2 Max Min measurement value 2 4 2 Parameter 1 group No Address Func R W Parameter Description Setting range Factory default 400051 0032 03 06 16 R W MODE Mode Input operation mode 0 F1 1 F2 2 F3 to 14 F15 15 F16 0 400052 0033 03 06 16 R W IN A Input A Sensor type 0 NPnhF 1 NPnmF 2 NPnlF 3 PNphF...

Page 22: ...R W PSt H Preset H H comparative value 0 to 99999 99999 400108 006B 03 16 R W 400109 006C 03 16 R W PSt L Preset L L comparative value 0 to 99999 1 0 400110 006D 03 16 R W 400111 006E 03 16 R W PStLL Preset LL LL comparative value 0 to 99999 1 0 400112 006F 03 16 R W 400113 0070 03 16 R W PScaH Prescale A Mantissa Prescale A mantissa 0 0001 to 9 9999 6 0000 400114 0071 03 16 R W 400115 0072 03 06 ...

Page 23: ...Bits per sec Communication Speed 0 2400 1 4800 2 9600 3 19200 4 38400 2 400158 009D 03 06 16 R W PRTY Parity bit Communication parity bit 0 NONE 1 EVEN 2 ODD 0 400159 009E 03 06 16 R W STP Stop bit Communication stop bit 0 1 1 2 1 400160 009F 03 06 16 R W RSwT Response waiting time Communication response waiting time 5 to 99 ms 20 400161 00A0 03 06 16 R W COmW Communication write Communication wri...

Page 24: ...2 Modbus Mapping Table 24 Copyright Reserved Autonics Co Ltd MCP MPC1 V1 0 1801US ...

Reviews: