Autonics LP-A070 Series Manual Download Page 4

Advanced Type 7 inch Color Logic Panel

V-27

SENSORS

CONTROLLERS

MOTION DEVICES

SOFTWARE

(J)

Temperature

Controllers

(K)

SSRs

(L)

Power

Controllers

(M)

Counters 

(N)

Timers

(O)

Digital 

Panel Meters 

(P)

Indicators

(Q)

Converters

(R)

Digital 

Display Units

(S)

Sensor

Controllers 

(T)

Switching

Mode Power

Supplies 

(U)

Recorders

(V)

HMIs

(W)

Panel PC

(X)

Field Network

Devices

 

Drawing function

Function

Description

Figure

Line/Multi line/Rectangle/Round rectangle/Polygon/Circle/Fan/Chord/Arc/ 

Rectangle scale/Circle scale/Semicircle scale/Image/Text

Object

Lamp

Displaying the value of the designated device in bit/word/multi lamp

Switch

Switching the status of the designated device or object with bit/word/change screen/special/multi switch

Numeric input/display

Displaying the value of the designated device/Inputting the value to the designated device  in number (DEC, 

HEX, OCT, BIN, REAL)

Text input/display

Displaying the value of the designated device/Inputting the value to the designated device in text  

(ASCII/Unicode)

Call window

Calling a window screen according to the conditions on the value of the designated device

Message

Displaying a message according to the conditions on the value of the designated device

Graph

Displaying the value of the designated device in bar/pie/panel meter/statistic/RealTime trend/Logging trend/

RealTime distribution/Logging distribution graph

Clock

Displaying time or date of the time

Recipe Editor

Editing recipe (project)

Logging table

Displaying the logging data (project) in a table

System logging table

Displaying the system logging data (project) in a table

Alarm explorer

Displaying the alarm group of alarm history (project) in a table

Alarm list

Displaying the data of alarm history (project) in a table.

Data list viewer/editor

Displaying/Editing the value of consecutive word device in a table

Option list

Displaying the data of the designated device/Inputting data to the designated device in a combo box

Move coord.

Displaying the object/Moving coordinate of the object according to the value of the  

designated device

Project

Link device

Reading/Writing the data between LP and controller (PLC) as long as setting according to the status of bit/

cycle condition

Flow alarm

Displaying alarm in the flowing text at the set position, when meeting the alarming condition

Alarm history

Saving data of alarming time, device, and information, when the value of the designated alarm-observing 

device meets the set condition

Scheduler

Executing a function (bit on/off/reversal, work value changing, script) according to the set condition (device/

cycle)

Recipe

Reading the value of the multiple devices/Writing the value to the multiple devices at once

Logging

Saving the value of the designated device, when meeting the condition (device/cycle)

System Logging

Saving system operation information of LP in a log file

Script

Writing Lua script by user

 

Logic function

Project

Creating/Managing individual or multiple project. changing PLC type, printing, print setting

Edit

Managing ladder/mnemonic editor, inserting/deleting line, managing rung, searching rung comment, search,  

replace, find step

Tool

Ladder tool: arrow, delete, vertical line, horizontal line, normally open contact, normally closed contact, rising input 

contact, falling input contact, output instruction, rising output contact, falling output contact, set, reset, application 

instruction, not instruction, register user defined function, user defined function
Program optimization, program checking, program checking options

View

Ladder/Mnemonic, device/variable name, device name & comment, decimal/hexadecimal view, signed/unsigned 

view, device/UW view, used devices, zoom in/out, font settings, color settings, toolbar

Online

Connecting, disconnecting, download, upload, change mode, start monitoring, stop monitoring, read information, 

change password, verify, change present value, system device, delete, firmware download, communication options

Debug

Run, stop run, trace, insert/remove break point, stop debugging, debug-step, debug-line, debug-scan,  

debug-1 scan, step in, step out, debug-bit, debug-word, forced I/O settings

window

Cascade, horizontal tile, vertical tile, arrange icon, external program connection

Help

Program information

Workspace

Program

Ladder/Mnemonic program editor

Parameter

Common: output while debugging, operating condition for extended module, device latch range settings, default 

filter value, time driven operation, time interrupt, timer range settings
Extension: input filter, external interrupt

Motion: common setting, operation setting, pattern setting
High speed counter

Variable/

Comment Managing and setting Variable/Comment by bit/word device
Monitoring Monitoring and registering device to monitor by bit/word device

 Function

Summary of Contents for LP-A070 Series

Page 1: ...point Output 16 point Simultaneous monitoring of multiple addresses and channels Monitoring device of the connected controllers even without user screen data Multilingual table function switching language of user screen by touching a button Large capacity of memory widen range of UB UW internal device 64MB user screen memory Using user screen drawing program atDesigner More variety functions objec...

Page 2: ... 25 Insulated resistance Over 100MΩ at 500VDC megger Ground 3rd grounding max 100Ω Noise immunity 0 5kV the square wave noise pulse width 1 by the noise simulator Withstanding voltage 500VAC 50 60Hz for 1 minute Vibration Mechanical 0 75mm amplitude at frequency of 10 to 55Hz for 1 min in each X Y Z direction for 1 hour Malfunction 0 5mm amplitude at frequency of 10 to 55Hz for 1 min in each X Y Z...

Page 3: ...age 24VDC Insulation method Photocoupler insulation Input resistance Contact X0 to X8 approx 10mA Contact X9 to XF approx 4mA Rated load voltage 24VDC Voltage range 19 2 to 28 8VDC Allowable load voltage range 19 2 to 28 8VDC Input resistance Contact X0 to X8 3 3 Contact X9 to XF 5 6 Max load current 0 1A 1 point 1 6A 1COM Response time 0 5ms Max voltage falling when ON Max 0 2VDC Common method 16...

Page 4: ...set position when meeting the alarming condition Alarm history Saving data of alarming time device and information when the value of the designated alarm observing device meets the set condition Scheduler Executing a function bit on off reversal work value changing script according to the set condition device cycle Recipe Reading the value of the multiple devices Writing the value to the multiple ...

Page 5: ...8 Non Used 9 Non Used 9 Non Used Ethernet port For connecting LAN cable and hub use direct cable and for connecting PC directly use cross cable USB Type USB Host USB Device Function Transferring Copying data between storage and LP A070 Firmware upgrade Bar code reader Printer Uploading Downloading a atDesigner project file Used as external storage by connecting to PC USB HOST can cover up to 32GB ...

Page 6: ...0 0 1 1 0 15 10 4 14 M4 185 134 194 125 28 5 6 5 Check the number of pin on the rear case before wiring Input Output Wiring LP A070 T9D6 7 C5R LP A070 T9D6 7 C5T Input wiring source type Input wiring source type Output wiring sync type Output wiring sync type 24VDC 8 9 A B C D E F 0 1 2 3 4 5 6 7 X0 X1 X2 X3 X4 X5 X6 X7 COM1 COM3 X8 X9 XA XB XC XD XE XF COM2 COM4 24VDC 8 9 A B C D E F 0 1 2 3 4 5 ...

Page 7: ...tact our service center to replace battery It may cause an explosion or a fire when using improper battery 1 Follow instructions in Cautions during Use Otherwise it may cause unexpected accidents 2 24VDC power supply should be insulated and limited voltage current or Class 2 SELV power supply device 3 Install a power switch or circuit breaker in the easily accessible place for supplying or disconn...