-|Transparent Guide|-
Cautions during Use
•
Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.
•
Power supply should be insulated and limited voltage/current or Class 2, SELV power supply
device.
•
Install a power switch or circuit breaker in the easily accessible place for supplying or
disconnecting the power.
•
Operate the product after supplying power to the product, input/output equipment, and
load. If operate product before supplying power, it may result in output error or malfunction.
•
Use a USB cable within 2 m.
•
Keep away from high voltage lines or power lines to prevent inductive noise. Do not use near
the equipment which generates strong magnetic force or high frequency noise.
•
Make a required space around the unit for radiation of heat, and do not block ventilation
openings.
•
Do not push the touch panel with a hard and sharp object or push the panel with excessive
force. It may result in fire or malfunction.
•
When skin is smeared with liquid crystal from the broken LCD, rinse with running water for
over 15 minutes. If it gets into the eyes, rinse eyes with running water for over 15 minutes and
contact a doctor.
•
This unit may be used in the following environments.
- Indoors (in the environment condition rated in ‘Specifications’)
- Altitude max. 2,000m
- Pollution degree 2
- Installation category II
Cautions during Wiring
•
For power supply, use the wire of which cross section is at least 0.75mm² and use the wire
of which cross section is at least 1.25mm² for grounding.
•
Use ring crimp terminal with at least 3mm of internal diameter and less than 6mm of
external diameter.
•
Do not apply power before power line connection.
•
Check power polarity.
•
Tighten the terminal screw with 0.5 to 0.6N.m torque.
•
Ground resistance should be less than 100Ω and ground it separately.
Product Components
•
Graphic panel + built in battery
•
4.6 / 5.7 / 7.0 inch: 4 fixing brackets
•
10.4 inch: 6 fixing brackets, CAN connector
•
Sold separately: communication cable
Manual
For the detailed information and instructions, please refer to the manuals, and be sure to follow
cautions written in the technical descriptions.
Visit Autonics web site to download manuals.
•
GP-A Series user manual
It describes general information about installation and system of GP-A Series.
•
atDesigner user manual
It describes how to design user screen and how to use HMI function.
•
GP/LP user manual for communication
It describes how to connect with external devices such as PLC.
❶ Screen size
046: 4.6 inch
057: 5.7 inch
070: 7.0 inch
104: 10.4 inch
❷ Display color
8: 262,144 color
9: 16,777,216 color
❸ Interface
Model
❸
RS232C
RS422
CAN
Micro SD
USB
Host
USB
Device Ethernet
GP-A
046/057/070
6
1
1
-
-
1
1
1
7
2
-
-
-
GP-A104
8
1
1
1
1
9
2
-
1
1
Ordering Information
This is only for reference.
For selecting the specific model, follow the Autonics web site.
GP
-
A
❶
-
T
❷
D
❸
Serial interface
RS232C, RS422
USB interface
USB Host, USB Device(USB2.0)
Ethernet interface
IEEE802.3(U), 10/100Base-T
CAN interface
24V CAN transceiver
External storage
Micro SD up to 32GB (FAT16/32)
Real-time controller
RTC embedded
Battery life cycle
3 years at 25℃
Supportive interface can be different up to model. For the detailed information, please refer to 'Ordering Information'.
Power supply
24 VDCᜡ
Allowable voltage range
90 to 110% of power supply
Power consumption
4.6 inch : ≤ 4.8 W, 5.7 / 7.0 inch : ≤ 7.2 W, 10.4 inch : ≤ 8.0 W
Insulated resistance
≥ 100 MΩ (500 VDCᜡ megger) (between all terminals and case)
Ground
3rd grounding (≤ 100 Ω)
Noise immunity
The square wave noise (pulse width: 1㎲) by the noise simulator ± 0.5 kV
Dielectric strength
500 VACᜠ 50/60 Hz for 1 minute (between all terminals and case)
Vibration
0.75 double amplitude at frequency of 10 to 55 Hz in each X, Y, Z
direction for 1 hour
Vibration (malfunction)
0.5 double amplitude at frequency of 10 to 55 Hz in each X, Y, Z
direction for 10 minutes
Shock
147 m/s² (approx. 15 G) in each X, Y, Z direction for 3 times
Shock (malfunction)
100 m/s² (approx. 10 G) in each X, Y, Z direction for 3 times
Ambient temperature
0 to 50℃, storage: -20 to 60℃ (a non freezing or condensation environment)
Ambient humidity
35 to 85%RH, storage : 35 to 85%RH (a non freezing or condensation
environment)
Protection structure
IP65 (front panel, IEC standard)
Language
Korean, English
Text
Bitmap and vector font
Memory for user screen
64MB
Number of user screen
100 pages
GP-A046
GP-A057
GP-A070
GP-A104
Screen size
4.6 inch
5.7 inch
7.0 inch
10.4 inch
LCD type
TFT Color LCD
Resolution
800×320 pixel
640×480 pixel
800×480 pixel
800×600 pixel
Display area
108×43.2 mm
115.2×86.4 mm 154.4×93.44 mm 211.2×158.4 mm
Display color
16,777,216 color 262,144 color
16,777,216 color 16,777,216 color
LCD view angle
(top/bottom/left/right)
Within 75°/70°
/80°/80° of each
Within 70°/70°
/80°/80° of each
Within 50°/60°
/65°/65° of each
Within 60°/70°
/80°/70° of each
Backlight
White LED
Luminance adjustment
Adjustable by software
Touch
Resistive type (4-wire)
Approval
ᜢ ᜣ
Unit weight
(packaged)
≈ 272 g
(≈ 382 g)
≈ 489 g
(≈ 644 g)
≈ 520 g
(≈ 706 g)
≈ 1.07 kg
(≈ 1.62 kg)
Specifications