Fiber Optic Amplifier
Energy saving function [
ESAV
]
A function to save unit's power consumption by reducing power supply to display parts in case of no setting input
within 60 sec.
● Selectable from 2 power saving modes
- Normal mode [
NOR
] : Main output indicator(OUT), PV/SV display part ON
- Energy saving mode 1 [
1SAV
] : Main output indicator(OUT) and PV display part ON
- Energy saving mode 2 [
2SAV
] : Main output indicator(OUT) ON
Light ON / Dark ON switching function [
LDON
]
A function to set Light ON - control output is ON when incident light level is higher than setting value Dark ON -
control output is ON when incident light level is lower than setting value.
Communication enable / disable setting function
[
COMM
]
A function to set communication write [enable(
ENA
) / disable(
DISA
)] for Slave amplifier units while certain instructions
(Load/Save/Copy) or Group teaching is in progress by the Master amplifier unit.
Lock function [
LOCK
]
Two types of key lock setting are available in order to prevent SV changes due to careless.
● In case of [
LOC2
]mode, it is required to disable the lock function first to enter into parameter mode.
Data Bank setting
A function to save settings for group amplifier units in each data Bank by using Master unit's command or by adjusting one
amplifier unit's setting and to load required data Bank when it is necessary without resetting for each unit's parameters and
setting values.
● LOAD [
LOAD
] : Loads preset dataBank(
BAK0
,
1
,
2
) and applies it to the amplifier unit.
Detailed Bank parameters can be read and changed.
● SAVE [
SAVE
] : Saves one amplifier unit settings in one of dataBank(
BAK0
,
1
,
2
).
● COPY [
COPY
] : Copies the currently loaded Bank by Master’s instructions to the other amplifier unit (1:1) or the whole
amplifier units (1: M).
● LOAD ALL [
LDAL
] : Selects one dataBank by Master’s instructions loads it to entire group units.
● SAVE ALL [
SVAL
] : Selects one dataBank by Master's instructions and saves it in entire group units.
※
Up to 3 dataBanks are available [
BAK0
,
1
,
2
] and each Bank can be read and changed.
It allows users to detect three different sensing objects using one amplifier unit without resetting each parameter.
※
For BF5-D1- , three dataBanks are available ([
BAK0
], [
BAK1
] and [
BAK2
]) so that three different sensing
object information can be saved. Each Bank can be read and changed. It allows users to detect three different
sensing objects with one amplifier unit without resetting each parameter.
※
DataBank function can be executed only if all amplifier units are in RUN mode.
※
Copy/Load All/Save All functions are applicable only if multiple amplifier units are connected.
※
If lock function is set(
LOC1
/
LOC2
) on amplifier units or if the Slave unit is set to communication disable[
DISA
],
Load and Save command for the unit is not executed.
OFF
LOC1
LOC2
Sensitivity setting
Data Bank mode
Program mode
Parameter initialization
※
: Check / Setting both available
: Check available
: Check / Setting both unavailable