background image

18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002

www.autonics.com  |  +82-2-2048-1577  |  [email protected]

-|Transparent Guide|-

Sensitivity Adjustment

Use the offered adjustment screwdriver. Do NOT turn with excessive force to prevent 

product damage.

STEP

Status

Adjuster

Descriptions

COARSE

FINE

01

-

MIN

 

─ ┼

Fix the COARSE adjuster at MIN and 

fix the FINE adjuster at center (▼).

02

Received

MIN

ON

 

─ ┼

Turn the COARSE adjuster to the 

right and fix it where the operation 

indicator lights up.

03

Received

 

ON

OFF

A

─ ┼

Turn the FINE adjuster to (-) 

direction and check the position 

where the operation indicator

turns OFF.

Turn the FINE adjuster again to (+) 

direction and check the position (A) 

where the operation indicator

lights up.

04

Interrupted

         

─ ┼

ON

OFF B

Turn the FINE adjuster to (+) 

direction and check the position 

where the operation indicator

lights up.

 

Turn the FINE adjuster again to (-) 

direction and check the position (B) 

where the operation indicator

turns OFF.

If the operation indicator does NOT 

light up: MAX = (B).

05

-

   

A

B

─ ┼

Set the adjuster at the mid position 

between (A) and (B) for optimal 

sensitivity.

06

Received

MIN

    

─ ┼

MAX

 

If you cannot adjust as above, set 

the FINE adjuster at MAX and follow 

the step again.

Operation mode

Light ON

Dark ON 

Received light

Received

Received

Interrupted

Interrupted

Operation 

indicator (red)

ON

ON

OFF

OFF

Transistor output

ON

ON

OFF

OFF

Operation timing chart

Feature Data: Reflective Type

Fiber optic unit model: FD-620-10

  

■ Sensing area

L

Sensing dis

tanc

e L (mm)

Operation area ℓ            (mm)

Left ← Center → Right

0

20

40

60

80

100

120

140

0 10

30

10

30

20

20

Feature Data: Through-beam Type

Fiber optic unit model: FT-420-10

  

■ Sensing area

Receiver

Emitter

L

200

100

100

200

0

0

50

100

150

200

250

300

350

400

450

Sensing dis

tanc

e L (mm)

Operation area ℓ            (mm)

Left ← Center → Right

Reviews: