background image

A-49

(A) 

Photo

electric 

sensor

(B) 

Fiber

optic

sensor

(C) 

Door/Area

sensor 

(D) 

Proximity

sensor 

(E) 

Pressure

sensor 

(F) 

Rotary

encoder 

(G) 

Connector/

Socket 

(H)

Temp.

controller

(I)

SSR/

Power

controller

(J) 

Counter 

(K) 

Timer 

(L) 

Panel

meter 

(M)

Tacho/

Speed/ Pulse

meter 

(N)

Display

unit

(O)

Sensor

controller 

(P)

Switching

mode power

supply 

(Q)

Stepper

motor&

Driver&Controller

(R)

Graphic/

Logic

panel

(S)

Field

network

device

(T) 

Software

(U) 

Other

Amplifier Built-in type with Universal voltage 

 Mounting and sensitivity adjustment

1. Supply the power to the photoelectric sensor, after 

setting the emitter and the receiver facing each other.

2. Set the receiver in center of position in the middle of the 

stability range of indicator adjusting the receiver or the 

emitter right and left, up and down.

3. After adjustment, check the stability of operation putting 

the object at the optical axis.

 If the sensing target is translucent body or smaller     

than ø16mm, it can be missed by sensor cause light 

penetrate it.

1. The sensitivity should be adjusted depending on a 

sensing target or mounting place.

2. Set the target at a position to be detected by the beam, 

then turn the adjustment VR until position 

 where the 

operation indicator turns ON from min. position of the 

adjustment VR.

3. Take the target out of the sensing area, then turn the 

adjustment VR until position 

 where the the operation 

indicator turns ON. If the indicator dose not turn ON, 

max. position is 

.

4. Set the adjustment VR at the center of two switching 

position 

.       

The sensing distance indicated on specification  chart is 

for 100×100mm of non-glossy white paper. Be sure that 

it can be different by size, surface and gloss of target.

1. Supply the power to the photoelectric sensor, after 

setting the photoelectric sensor and the reflector(MS-2)

in face to face.

2. Set the photoelectric sensor in the position which 

indicator turns on, as adjusting the reflector or the 

sensor right and left, up and down.

3. Fix both units tightly after checking that the unit detects        

the target.

If using more than 2 photoelectric sensors in parallel,          

the space between them should be more than 30cm. 

If reflectance of target is higher than non-glossy white          

paper, it might cause malfunction by reflection from          

the target when the target is near to photoelectric sensor. 

Therefore put enough space between the target and the 

photoelectric sensor or the surface of the target should 

be installed at angle of 30° to 45° against optical axis. 

(When a sensing target with high reflectance near by, 

photoelectric sensing with the polarizing filter should be 

used.)

Sensitivity adjustment: Refer to the diffuse reflective type’s.

 Through-beam type

 Diffuse reflective type

 Retroreflective type

Emitter

Adjust

Right/Left

Adjust Up/Down

Receiver

Optical axis

<MS-4>

Sensing

target

Diffuse reflective

Optimal

position

Vertical direction

polarizing filter

Horizontal direction

polarizingfilter

MS-2

Receiver

Emitter

The light passed through the polarizing filter of the emitter 

reaches to the MS-2 reflector converting as horizontal 

direction. It reaches to the receiver element of polarizing 

filter converting as vertical by the MS-2 reflector. Therefore, 

this type can also detect reflective mirror.

 Retroreflective type with polarizing filter

  If the mounting place is too narrow, 

please use MS-4 instead of MS-2.

Adjust

Right/Left

Adjust Up/Down

Reflector

(MS-2)

Optical axis

Retroreflective

Reflector

(MS-2)

30° to 45°

Sensing

target

Summary of Contents for BEN Series

Page 1: ...s Malfunction 1 5mm amplitude or 300m s2 at frequency of 10 to 55Hz for 1 min in each of X Y Z directions for 10 minutes Shock Mechanical 500m s approx 50G in each of X Y Z directions for 3 times Malfunction 100m s approx 10G in each of X Y Z directions for 3 times Environ ment Ambient illumination Sunlight Max 11 000 Incandescent lamp Max 3 000 Receiver illumination Ambient temperature 20 to 65 s...

Page 2: ...ce 240V the square wave noise pulse width 1 by the noise simulator Dielectric strength 1000VAC 50 60Hz for 1minute Vibration 1 5mm amplitude or 300m s2 at frequency of 10 to 55Hz for 1 min in each of X Y Z directions for 2 hours Shock 500m s approx 50G in each of X Y Z directions for 3 times Environ ment Ambient illumination Sunlight Max 11 000 Incandescent lamp Max 3 000 Receiver illumination Amb...

Page 3: ...ector MS 2 50 30 0 30 50 Operation angle θ 5 3 1 0 Sensing distance L m Operation level Stable operation level Left Right Center Parallel shifting characteristic Measuring method Data Sensing area mm ℓ1 L Reflector MS 2 ℓ1 ℓ1 4 3 2 1 0 50 50 0 30 50 Sensing distance L m Operation level Stable operation level Left Right Center Retroreflective type Built in polarizing filter Sensor angle characteris...

Page 4: ...t Interrupted light Operation indicator red LED ON OFF Transistor output ON OFF Operation mode Dark ON Receiver operation Received light Interrupted light Operation indicator red LED ON OFF Transistor output ON OFF In case of product with the output protection device if terminals of control output are short circuited or overcurrent condition exists the control output turns OFF due to protection ci...

Page 5: ...C 10 24 240VAC 10 24 240VDC 10 Brown Blue White Black Gray Brown Tc Ta Tb Blue Emitter Receiver Sensing target 12 24VDC 10 12 24VDC 10 Brown Blue White Black PNP NPN Brown Blue Sensing target Reflector MS 2 24 240VAC 10 24 240VDC 10 Blue White Black Gray Brown Tc Ta Tb Sensing target Reflector MS 2 12 24VDC 10 Blue White Black PNP NPN Brown Sensing target 24 240VAC 10 24 240VDC 10 Blue White Black...

Page 6: ... be different by size surface and gloss of target 1 Supply the power to the photoelectric sensor after setting the photoelectric sensor and the reflector MS 2 in face to face 2 Set the photoelectric sensor in the position which indicator turns on as adjusting the reflector or the sensor right and left up and down 3 Fix both units tightly after checking that the unit detects the target If using mor...

Reviews: