background image

-|Transparent Guide|-

TCD210204AB

AC Power Input

EtherCAT Comm. Type  

2-Phase Closed-loop Stepper 

Motor Driver

AiCA-D-EC Series

PRODUCT MANUAL

For your safety, read and follow the considerations written in the instruction 
manual, other manuals and Autonics website.

The specifications, dimensions, etc. are subject to change without notice for product 
improvement. Some models may be discontinued without notice. 

Features

• Closed-loop system with real-time position control
• 

High speed & high torque drive without missing steps

• Supports 200 - 240 VACᜠ  AC power

• Multi-axis simultaneous control with EtherCAT communication
• 

Windows-based software (atMotion) for easy parameter setting and monitoring

• 

7-segment display for alarm / status reading

• 

Supports torque mode

• Supports Auto Current Down mode
• 

Built-in brake type motors available (AiCA-D-B-EC Series)

• Built-in 

geared/rotary actuator type motors available

ᜢ ᜣ ᜥ

Safety Considerations

• 

Observe all ‘Safety Considerations’ for safe and proper operat

ion to avoid hazards.

• 

᜸ symbol in

dicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01. 

Fail-safe device must be installed when using the unit with machinery that may 

cause serious injury or substantial economic loss. (e.g. nuclear power control, 

medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, 

safety equipment, crime / disaster prevention devices, etc.)

Failure to follow this instruction may result in personal injury, economic loss or fire.

02. 

Do not use the unit in the place where flammable / explosive / corrosive gas, high 

humidity, direct sunlight, radiant heat, vibration, impact or salinity may be present.

Failure to follow this instruction may result in explosion or fire.

03. 

Do not connect, repair, or inspect the unit while connected to a power source.

Failure to follow this instruction may result in fire or electric shock.

04. 

Install the unit after considering counter plan against power failure.

Failure to follow this instruction may result in personal injury, economic loss or fire.

05. 

Re-supply power after min. 20 sec from disconnected power.

It may cause damage or malfunction of the product

06. 

Check ‘Connections’ before wiring.

Failure to follow this instruction may result in fire.

07. 

For installing the unit, ground it exclusively and use over AWG 18 (0.75 mm

2

) ground cable.

Failure to follow this instruction may result in electric shock.

08. 

Do not disassemble or modify the unit.

Failure to follow this instruction may result in fire or electric shock.

09. 

Insulate the connector not to be exposed.

Failure to follow this instruction may result in electric shock.

10. 

Install the driver in the housing or ground it.

Failure to follow this instruction may result in personal injury, fire or electronic shock.

11. 

Do not touch the unit during or after operation for a while.

Failure to follow this instruction may result in burn or electric shock due to high 

temperature of the surface.

12. 

Do not remove the connector during or after operation for a while.

Failure to follow this instruction may result in electric shock, or product damage.

13. 

Emergency stop directly when error occurs.

Failure to follow this instruction may result in personal injury or fire.

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. 

When connecting the power input, use AWG18 (0.75 mm

2

) cable or over.

02. 

Brake is non-polar. When connecting the brake, use AWG24 (0.2 mm

2

) cable or over.

Failure to follow this instruction may result in fire or malfunction due to contact failure.

03. 

To use the motor safely, do not apply external force to the motor.

04.  It is recommended to use STOPPER for the vertical load.
05. 

Install over-current prevention device (e.g. the current breaker, etc.) to connect 

the driver with power.

Failure to follow this instruction may result in fire.

06. 

Check the control input signal before supplying power to the driver.

Failure to follow this instruction may result in personal injury or product damage by 

unexpected driver movement.

07. 

Install a safety device to maintain the vertical position after turn off the power of 

this driver.

Failure to follow this instruction may result in personal injury or product damage by 

releasing holding torque of the motor.

08.  Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or product damage.

09. 

Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire or electric shock.

10. 

The driver may overheat depending on the environment.

 

Install the unit at the well-ventilated environment and forced cooling with a cooling fan.

Failure to follow this instruction may result in product damage or degradation by heat.

11. 

Keep the product away from metal chip, dust, and wire residue which flow into the unit.

Failure to follow this instruction may result in fire or product damage. 

12. 

Use the designated motor only.

Failure to follow this instruction may result in fire or product damage.

Summary of Contents for AiCA-D-EC Series

Page 1: ...in electric shock 08 Do not disassemble or modify the unit Failure to follow this instruction may result in fire or electric shock 09 Insulate the connector not to be exposed Failure to follow this instruction may result in electric shock 10 Install the driver in the housing or ground it Failure to follow this instruction may result in personal injury fire or electronic shock 11 Do not touch the u...

Page 2: ...normal sound from ball bearing of the unit Damage and stress of lead cable of the unit Connection error with motor Inconsistency between the axis of motor output and the center concentric eccentric declination of the load etc This product does not contain a protection function for a motor unit This unit may be used in the following environments Indoors in the environment condition rated in Specifi...

Page 3: ...le support FoE Physical layer 100BASE TX IEEE802 3 Connection cable CAT5e class or over Shield type SF FTP S FTP SF UTP Max comm distance Within 100 m distance between nodes Baud rate 10 100 Mbps Distributed clock DC cycle 250 us 500 us 1 ms 2 ms 4 ms 8 ms Node ID setting ECAT ID switch setting 1 to 99 Physical address setting at Master 1 to 65535 Topology Star Line Tree 01 EtherCAT is registered ...

Page 4: ...withequivalentorsubstitute EtherCATdedicatedcablemustbeusedandtheperformancecannotbeguaranteed whenusingothercables Type Connector specifications Manufacture CN1 Motor Encoder connector 5557 14R connectorterminal 5556T Molex CN2 Power connector 5ESDVM 06P OR Dinkle CN3 EtherCAT comm connector RJ45 CN4 I O connector 10120 3000PE Housing 10320 52F0 008 3M CN5 Brake connector ESC250V S2330704P Dinkle...

Page 5: ... 1 13 IN5 Black 2 14 In Position Red 2 15 Alarm Black 3 16 OUT1 Red 3 17 OUT2 Black 4 18 OUT3 Red 4 19 OUT4 Black 5 20 GEX Red 5 Recommended to use ferrite core at both ends of the cable The model name is 010 020 030 050 070 100 150 200 which indicates the cable length E g CO20 MP070 R 7 m I O cable SoldSeparately Motor EncoderCable Fixed type C1D14M Flexible type C1DF14M Recommended to use ferrit...

Reviews: