Page 7
IronHorse GSD3 DC Drives User Manual – 1st Ed, Rev C – 10/15/2019
Installation and Wiring
Install open-frame drives in an enclosure with a volume at least three
times the volume of the open-frame drive.
Do not mount GSD3-24x-2Cx DC drive where ambient temperature is outside
the range of -10 to 45 °C (14 to 113 °F).
Do not mount GSD3-24x-3N4 DC drive where ambient temperature is outside
the range of -10 to 40 °C (14 to 104 °F).
i
mproper
installation
or
operation
of
this
dc d
rive
may
cause
injury
to
personnel
or
drive
failure
. t
he
drive
must
be
installed
in
accordance
With
local
,
state
,
and
national
safety
codes
.
m
ake
certain
that
the
poWer
supply
is
disconnected
before
attempting
to
service
or
remove
any
components
!!! i
f
the
poWer
disconnect
point
is
out
of
sight
,
lock
it
in
disconnected
position
and
tag
it
to
prevent
unexpected
application
of
poWer
. o
nly
a
qualified
electrician
or
service
personnel
should
perform
any
electrical
troubleshooting
or
maintenance
. a
t
no
time
should
circuit
continuity
be
checked
by
shorting
terminals
With
a
screWdriver
or
other
metal
device
.
b
efore
attempting
to
Wire
the
dc d
rive
,
make
sure
all
poWer
is
disconnected
.
r
echeck
code
designation
to
assure
proper
voltage
is
present
for
the
dc d
rive
.
c
arefully
select
proper
Wire
size
for
current
and
voltage
drop
.
l
imit
the
voltage
drop
through
the
Wiring
to
5%
of
the
line
voltage
at
full
load
.
caution!! t
urn
poWer
off
While
making
Wiring
connections
.
caution!! d
o
not
attempt
to
perform
a
hi
-
pot
test
across
the
ac
lines
With
the
dc
drive
in
the
circuit
. t
his
Will
result
in
immediate
or
long
-
term
damage
to
the
drive
.
Fusing
Refer to the wiring diagram for fusing information.
Terminals
GSD3 Wiring Terminals
GSD Model
Type
Wire Range
Tightening Torque
GSD3-xxx-xxx
Spade connector lugs
n/a
n/a
Wiring Diagram
GSD3-xxx-xxx Wiring Diagram
Speed Pot
(prewired)
GSD3-xxx-xxx
* For wiring connections, use customer-supplied Sta-Kon 0.25 in x 0.25 in spade connectors or similar.
** +F connection is only for Shunt Wound motor; NOT for Permanent Magnet motor.
For motors with dual voltage field, i.e. 50/100V or 100/200V, connect the highest value.
*** Use normal-blow fuses in series with all ungrounded (hot) AC inputs, rated to 125% of motor current.
NOTE: Fuse both AC input lines for 240 VAC input, where both lines are hot. For line-to-neutral
circuits, fuse the hot input line and connect it to AC1.
**** GSD3-240-3N4 drives include a replaceable built-in fuse wired in line with AC1.
(Fuse is 250VAC, 6.3A Littlefuse 21606.30 or equivalent.)
+ F
AC1(L)
AC2(N)
- FIELD
- ARM
+ ARM
MAX
MIN
I.R.
motor plus (+) Field wire (of Shunt Wound motor) **
incoming AC line *** ****
incoming AC line ***
motor minus (-) Field wire (of Shunt Wound motor)
motor minus (-) Armature wire
motor plus (+) Armature wire
Enclosed models
GSD3-xxx-3N4
include prewiring
inside of front
cover.
* Spade connector lugs