IronHorse GSD3 DC Drives User Manual  –  1st Ed, Rev C  –  10/15/2019

Installation and Wiring

Install open-frame drives in an enclosure with a volume at least three 

times the volume of the open-frame drive.
Do not mount GSD3-24x-2Cx DC drive where ambient temperature is outside 

the range of -10 to 45 °C (14 to 113 °F). 

Do not mount GSD3-24x-3N4 DC drive where ambient temperature is outside 

the range of -10 to 40 °C (14 to 104 °F).

i

mproper

 

installation

 

or

 

operation

 

of

 

this

 dc d

rive

 

may

 

cause

 

injury

 

to

 

personnel

 

or

 

drive

 

failure

.  t

he

 

drive

 

must

 

be

 

installed

 

in

 

accordance

 

With

 

local

state

and

 

national

 

safety

 

codes

.  

m

ake

 

certain

 

that

 

the

 

poWer

 

supply

 

is

 

disconnected

 

before

 

attempting

 

to

 

service

 

or

 

remove

 

any

 

components

!!!  i

f

 

the

 

poWer

 

disconnect

 

point

 

is

 

out

 

of

 

sight

lock

 

it

 

in

 

disconnected

 

position

 

and

 

tag

 

it

 

to

 

prevent

 

unexpected

 

application

 

of

 

poWer

.  o

nly

 

a

 

qualified

 

electrician

 

or

 

service

 

personnel

 

should

 

perform

 

any

 

electrical

 

troubleshooting

 

or

 

maintenance

.  a

t

 

no

 

time

 

should

 

circuit

 

continuity

 

be

 

checked

 

by

 

shorting

 

terminals

 

With

 

a

 

screWdriver

 

or

 

other

 

metal

 

device

.

b

efore

 

attempting

 

to

 

Wire

 

the

 dc d

rive

make

 

sure

 

all

 

poWer

 

is

 

disconnected

.   

r

echeck

 

code

 

designation

 

to

 

assure

 

proper

 

voltage

 

is

 

present

 

for

 

the

 dc d

rive

.   

c

arefully

 

select

 

proper

 

Wire

 

size

 

for

 

current

 

and

 

voltage

 

drop

.   

l

imit

 

the

 

voltage

 

drop

 

through

 

the

 

Wiring

 

to

 5% 

of

 

the

 

line

 

voltage

 

at

 

full

 

load

.

caution!!  t

urn

 

poWer

 off 

While

 

making

 

Wiring

 

connections

.

caution!!  d

o

 

not

 

attempt

 

to

 

perform

 

a

 

hi

-

pot

 

test

 

across

 

the

 ac 

lines

 

With

 

the

 dc 

drive

 

in

 

the

 

circuit

.  t

his

 

Will

 

result

 

in

 

immediate

 

or

 

long

-

term

 

damage

 

to

 

the

 

drive

.

Fusing

Refer to the wiring diagram for fusing information.

Terminals

   

GSD3 Wiring Terminals

GSD Model

Type

Wire Range

Tightening Torque

GSD3-xxx-xxx

Spade connector lugs

n/a

n/a

Wiring Diagram

GSD3-xxx-xxx Wiring Diagram

Speed Pot

(prewired)

GSD3-xxx-xxx

*  For wiring connections, use customer-supplied Sta-Kon 0.25 in x 0.25 in spade connectors or similar.

**  +F connection is only for Shunt Wound motor; NOT for Permanent Magnet motor.

    For motors with dual voltage field, i.e. 50/100V or 100/200V, connect the highest value.

***  Use normal-blow fuses in series with all ungrounded (hot) AC inputs, rated to 125% of motor current.

      NOTE: Fuse both AC input lines for 240 VAC input, where both lines are hot.  For line-to-neutral 

      circuits, fuse the hot input line and connect it to AC1.

****  GSD3-240-3N4 drives include a replaceable built-in fuse wired in line with AC1.

       (Fuse is 250VAC, 6.3A Littlefuse 21606.30 or equivalent.)

+ F

AC1(L)

AC2(N)

- FIELD

- ARM

+ ARM

MAX

MIN

I.R.

motor plus (+) Field wire (of Shunt Wound motor) **

incoming AC line *** ****

incoming AC line ***

motor minus (-) Field wire (of Shunt Wound motor)

motor minus (-) Armature wire

motor plus (+) Armature wire

Enclosed models

GSD3-xxx-3N4

include prewiring

inside of front

cover.

* Spade connector lugs

Summary of Contents for IRONHORSE GSD3 Series

Page 1: ...Page 1 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 GSD3 Series DC Drives User Manual User Manual Number IH GSD3 User M...

Page 2: ...le as on line control equipment in hazardous environments requiring fail safe performance such as in the operation of nuclear facilities aircraft navigation or communication systems air traffic contro...

Page 3: ...included in this manual Who Should Read This User Manual This manual contains important information for those who will install maintain and or operate any of the GSD3 Series DC Drives Technical Suppor...

Page 4: ...ts Standard Features Dual voltage models of 12 24 VAC or 120 240 VAC input Full wave bridge power supply Adjustable minimum and maximum speeds Adjustable IR Compensation Fixed Acceleration 0 5 seconds...

Page 5: ...on 1 of base speed Maximum Speed adjustable from 40 to 120 of base speed Minimum Speed adjustable from 0 to 30 of maximum speed Acceleration 0 5s fixed Deceleration 0 5s fixed Dynamic Braking no Plugg...

Page 6: ...Page 6 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 Dimensions GSD3 24x 2CJ dimensions in mm GSD3 24x 2CL dimensions in mm GSD3 24x 3N4 dimensions in mm...

Page 7: ...it the voltage drop through the wiring to 5 of the line voltage at full load CAUTION Turn power OFF while making wiring connections CAUTION Do not attempt to perform a hi pot test across the AC lines...

Page 8: ...n the CW direction until the maximum desired speed is obtained 5 Turn the Speed pot fully CCW 6 Adjust the MIN trim pot in the CW direction until deadband or the desired speed is obtained TRIM POT ADJ...

Page 9: ...Page 9 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 BLANK PAGE...

Page 10: ...Page 10 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 BLANK PAGE...

Page 11: ...Page 11 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 BLANK PAGE...

Page 12: ...Page 12 IronHorse GSD3 DC Drives User Manual 1st Ed Rev C 10 15 2019 Literature Number LT134 Drawing Number A 5 3901C...

Reviews: