AutomationDirect DURApulse GS20 Quick Start Manual Download Page 8

Page 8

DURA

pulse

 GS20 AC Drive Quick-Start Guide – 1st Ed, Rev C  03/03/2022

DURA

pulse

 GS20 AC Drive Quick-Start Guide

GS20_QSP 1st Edition, Rev C  03/03/2022

GS20 Frame E

Units = mm [in]

MOUNTING HOLE

DETAIL

MODELS BY 

FRAME SIZE:
FRAME_E1

GS23-2010

GS23-2015

GS23-4015

GS23-4020

130.0

[5.12]

5.5

[0.22]

5.5

[0.22]

 115.0

 [4.53]

 236.8

 [9.32]

 250.0

 [9.84]

6.0

 [0.24]

185.0

 [7.28]

GS20 Frame F

Units = mm [in]     

MOUNTING HOLE

DETAIL

MODELS BY 

FRAME SIZE:

FRAME_F1

GS23-2020

GS23-4025

GS23-4030

 154.0

 [6.06]

8.4

[0.33]

8.4

[0.33]

 175.0

 [6.89]

 279.5

 [11.00]

 300.0

 [11.81]

6.5

 [0.26]

 192.0

 [7.56]

NEMA 1 Conduit Boxes

The GS20 drives can optionally be fitted to a NEMA1 conduit box, with one available box per frame size.  The dimensional diagrams below show how the box will 

change the dimensions of the GS20 unit.

GS20 Frame A Conduit Box

 71.5

 [2.81]

 86.6

 [3.41]

 102.1

 [4.02]

GS20 Frame B Conduit Box

 72.0

 [2.83]

 87.7

 [3.45]

 87.0

 [3.43]

GS20 Frame C Conduit Box

 87.0

 [3.43]

 89.2

 [3.51]

 75.2

 [2.96]

GS20 Frame D Conduit Box

 103.7

 [4.08]

 88.5

 [3.48]

 52.3

 [2.06]

GS20 Frame E Conduit Box

 124.5

 [4.90]

 87.1

 [3.43]

 58.4

 [2.30]

GS20 Frame F Conduit Box

 168.5

 [6.63]

 90.8

 [3.57]

 72.6

 [2.86]

Models by Frame Size

Model

Frame

GS23-2010 

GS23-2015 

GS23-4015 

GS23-4020

E1

Models by Frame Size

Model

Frame

GS23-2020 

GS23-4025 

GS23-4030

F1

Units = mm [in]

Summary of Contents for DURApulse GS20

Page 1: ...ith 3 phase motors only Ground to the motor STO1 and STO2 both must be wired through appropriate N C safety rated contacts to DCM or the factory installed jumpers must be left in place With this minimal wiring the drive can be operated via the keypad to test the motor and drive installation See the Parameter Set Up page 4 section to configure the drive for keypad operation Recommended Safety Wirin...

Page 2: ...rminals Notes If you install at Ta 45 C above environment please use copper wire with a 600V voltage rating and temperature resistance of 90 C or higher For UL compliant installation you must 1 Use 75 C temperature resistant copper wire or better Do not reduce wire gauge when using higher temperature wire 2 Use the specific ring lug part listed in the table below 3 Use crimp tool KST2000D 1322 or ...

Page 3: ... the current PLC setting Press the UP or DOWN arrow keys to change the PLC setting then press ENTER to confirm MENU UP DOWN ENTER Displays the current PLC setting RUN FWD REV STOP PLC Enable the counter by setting parameter 00 04 to 1 See the user manual for full instructions on using the counter MENU Displays the counter value After selecting the desired menu option press ENTER to bring up the pa...

Page 4: ... Reset to GS2 mode 2 of 2 0 00 06 Firmware Version Read Only n a 00 10 Control Mode 0 Speed mode 2 Torque mode 0 00 11 Speed Control Mode 0 VF IM V F control 1 VFPG IM V F control Encoder 2 SVC Parameter 05 33 set as IM or PM 5 FOC Field Oriented Control 0 00 16 Load Selection 0 VT 1 CT 1 00 20 Frequency Command Source Auto 0 Digital keypad 1 Communication RS 485 input 2 External analog input refe...

Page 5: ...the motor coil 32 δ connection for the motor coil 33 Zero speed actual output frequency 34 Zero speed including STOP actual output frequency 35 Error output selection 1 P06 23 36 Error output selection 2 P06 24 37 Error output selection 3 P06 25 38 Error output selection 4 P06 26 40 Speed reached including STOP 42 Crane function 43 Motor speed detection 44 Low current output use with P06 71 06 73 ...

Page 6: ...Hz Comply with IEC 60068 2 6 Non operating 2 5 G peak 5Hz 2kHz 0 015 maximum displacement Impact Operating IEC EN60068 2 27 15G 11ms Non operating 30G Protection Level IP40 main unit IP20 wiring area main circuit terminals and control terminals all frame types and the vent near the capacitor on frame C D E and F types To prevent personal injury please make sure that the case and wiring are install...

Page 7: ...s mm in MOUNTING HOLE DETAIL MODELS BY FRAME SIZE FRAME_C1 GS21 11P0 GS21 22P0 GS21 23P0 GS23 23P0 GS23 25P0 GS23 43P0 GS23 45P0 GS23 53P0 GS23 55P0 87 0 3 43 5 5 0 22 5 5 0 22 73 0 2 87 144 5 5 69 157 0 6 18 5 0 0 20 152 0 5 98 GS20 Frame D Units mm in MOUNTING HOLE DETAIL MODELS BY FRAME SIZE FRAME_D1 GS23 27P5 GS23 47P5 GS23 4010 GS23 57P5 GS23 5010 94 0 3 70 5 5 0 22 5 5 0 22 109 0 4 29 193 8 ...

Page 8: ...6 5 0 26 192 0 7 56 NEMA 1 Conduit Boxes The GS20 drives can optionally be fitted to a NEMA1 conduit box with one available box per frame size The dimensional diagrams below show how the box will change the dimensions of the GS20 unit GS20 Frame A Conduit Box 71 5 2 81 86 6 3 41 102 1 4 02 GS20 Frame B Conduit Box 72 0 2 83 87 7 3 45 87 0 3 43 GS20 Frame C Conduit Box 87 0 3 43 89 2 3 51 75 2 2 96...