Automationdirect.com Productivity 2000 P2-16TR Manual Download Page 3

C1

1
2
3
4
5
6
7
8

C2

9

10
11
12
13
14
15
16

6 - 27 VDC

6 - 120 VAC

50 - 60 Hz

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

EXTERNAL

FUSE

RECOMMENDED

6 - 27 VDC

6 - 120 VAC

50 - 60 Hz

123456789

10
11
12

18

13
14
15
16
17

C1

1
2
3
4
5
6
7
8

C2

9

10
11
12
13
14
15
16

135 - 240 VAC

50 - 60 Hz

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

C1 and C2 Must

Be Linked Externally

for this Voltage Range

12345678

91

01
11
21

8

13
14
15
16
17

    6–27 VDC

    6–120 VAC

135–240 VAC

  50–60 Hz

8A Max

User Supplied

External Fuse

 

Sales 800-633-0405 

www.productivity2000.com 

3

Wiring Diagram and Schematic

Wiring Options

 

1

ZIPLink Connection System 

Cable + ZIPLink Module = Complete System

ZIPLink pre-wired  

terminal block cables

0.5m (1.6FT) cable
1.0m (3.3FT) cable
2.0m (6.6FT) cable

ZIPLink Modules

Feed through 

ZL-P2-CBL18
ZL-P2-CBL18-1
ZL-P2-CBL18-2

ZL-RTB20

 

2

Terminal Block with pigtail cable

1.0m (3.3FT) cable
2.0m (6.6FT) cable

ZL-P2-CBL18-1P
ZL-P2-CBL18-2P

3

Screw Terminal Block only

P2-RTB
(Quantity 1)

4

Spring Clamp Terminal Block only

P2-RTB-1
(Quantity 1)

Summary of Contents for Productivity 2000 P2-16TR

Page 1: ... OFF to ON Response m 10ms ON to OFF Response m 10ms Status Indicators Logic Side 16 points Commons 2 Isolated 8 point common External Fuses user supplied 8A Max Warranty Thirty day money back guarantee Two year limited replace ment See www productivity2000 com for details Terminal Block sold separately see wiring options on page 3 P2 16TR Relay Output The P2 16TR Relay Output Module provides sixt...

Page 2: ...plication to display the module s product insert 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot swapping procedure for exceptions WIRESTRIP LENGTH WIRESTRIP LENGTH Step One Align module catch with base slot and rotate module into connector Locked Unlocked Step Two Pull top locking tab toward module ...

Page 3: ...6 17 6 27 VDC 6 120 VAC 135 240 VAC 50 60 Hz 8A Max User Supplied External Fuse Sales 800 633 0405 www productivity2000 com 3 Wiring Diagram and Schematic Wiring Options 1 ZIPLink Connection System Cable ZIPLink Module Complete System ZIPLink pre wired terminal block cables 0 5m 1 6FT cable 1 0m 3 3FT cable 2 0m 6 6FT cable ZIPLink Modules Feed through ZL P2 CBL18 ZL P2 CBL18 1 ZL P2 CBL18 2 ZL RT...

Page 4: ...t any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product General Specifications Operating Temperature 0 to 60 C 32 to 140 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 5 to 95 non condensing Environmental Air No corrosive gases permitted Vibration IEC60068 2 6 Test Fc Shock IEC60068 2 27 Tes...

Reviews: