Automationdirect.com Productivity 2000 P2-04DA Manual Download Page 4

4

Tech Support 770-844-4200

www.productivity2000.com

QR Code

Use any QR Code reader application to 

display the module’s product insert.

Important Hot-Swap Information

The Productivity2000 System supports hot-swap! 

Individual modules can be taken offline, removed, and 

replaced while the rest of the system continues con-

trolling your process. Before attempting to use the hot-

swap feature, be sure to read the hot-swap topic in the 

programming software’s help file or our online documen-

tation at AutomationDirect.com for details on how to plan 

your installation for use of this powerful feature.

Align

with slot

2

 rotate

to seated

position

Module Installation

WARNING:

 

Do not apply field power until 

the following steps are completed. See 

hot-swapping procedure for  

exceptions.

WIRE STRIP

LENGTH

WIRE STRIP

LENGTH

Step One: 

Align module 

catch with base slot and 

rotate module into  

connector.

Locked

Unlocked

Step Two: 

Pull top locking tab 

toward module face. Click indi-

cates lock is  

engaged.

Step Three: 

Attach field wiring using the removable 

terminal block or ZIPLink wiring  

system.

Caution: 

If possible, remove field power prior to  

proceeding. If not, then 

EXTREME

 care 

MUST 

be taken 

to prevent damage to the module, or even personal injury 

due to a short circuit from the live terminal block.

Summary of Contents for Productivity 2000 P2-04DA

Page 1: ... information that was available at the time it was printed At AutomationDirect com we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product Removable Terminal Block...

Page 2: ... Mode Voltage outputs 0V or 0mA current outputs Load Impedance Minimum External Power Supply 1000Ω voltage outputs 19 2 30 VDC 0 755Ω Sinking 0 600Ω Sourcing 19 2 VDC 0 875Ω Sinking 0 700Ω Sourcing 21 6 VDC 0 1000Ω Sinking 0 855Ω Sourcing 24VDC 0 1110Ω Sinking 0 970Ω Sourcing 26 4 VDC 0 1350Ω Sinking 0 1150Ω Sourcing 30VDC Maximum Capacitive Load 0 01μF maximum voltage outputs Maximum Inductive Lo...

Page 3: ...DC User Supplied Power Transmitter Power Supply AC or DC 4 wire 4 20mA Load Transmitter Power Supply I I V1 I1 I1 COM V2 I2 24VDC I2 24VDC 24VDC 24VDC 24 VDC User Supplied Power CH1 DAC CH2 DAC ANALOG CIRCUIT POWER ANALOG CIRCUIT COMMON INTERNAL MODULE CIRCUITRY voltage sink source 4 20 mA current sinking 4 20 mA current sourcing voltage sink source 4 20 mA current sinking 4 20 mA current sourcing...

Page 4: ...n your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot swapping procedure for exceptions WIRESTRIP LENGTH WIRESTRIP LENGTH Step One Align module catch with base slot and rotate module into connector Locked Unlocked Step Two Pull top locking tab toward mod...

Page 5: ... Bit Item Range with sink source option and Stop Mode Value may also be assigned Wiring Options 1 ZIPLink Connection System Cable ZIPLink Module Complete System ZIPLink pre wired terminal block cables 0 5 m 1 6 ft cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZIPLink Modules Feed through ZL P2 CBL18 ZL P2 CBL18 1 ZL P2 CBL18 2 ZL RTB20 2Terminal Block with pigtail cable 1 0 m 3 3 ft cable 2 0 m 6 6 ...

Page 6: ...0 0 0 0 0 1 2 3 4 5 6 6 5 7 0 0 0 0 0 0 0 Level Transmitter Tank Level 7 0 0 0 0 0 0 0 Select the minimum and maximum values of the raw input signal These values will relate to the minimum and maximum scaled values 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 The Scale Linear function can be used to Convert an application specific range to a range which is native to the analog output module Make other linear con...

Page 7: ...nto the cycling Status Info screen This screen will auto cycle with status information PASSED SELF TEST P2 04DA Fw Rev 1 00 1 10V 2 mA SRC 3 mA SNK 4 10V DISPLAY SETUP INFO DISPLAY UNITS DECIMAL COUNTS DISPLAY UNITS HEX COUNTS DISPLAY STATUS INFO DISPLAY UNITS VOLT OR MILLIAMP 1 00000 2 00000 3 00000 4 00000 1 0000H 2 0000H 3 0000H 4 0000H 1 0 000V 2 4 00 3 13 90 4 4 741V End of Status Menu List M...

Page 8: ...8 Tech Support 770 844 4200 www productivity2000 com Document Name Edition Revision Date P2 04DA DS 1st Ed 3 9 2015 Copyright 2015 AutomationDirect com Incorporated All Rights Reserved Worldwide ...

Reviews: