background image

2

Tech Support 770-844-4200

www.productivity1000.com

QR Code

Use any QR Code reader application to 

display the module’s product insert.

P1-08TD1

P1-08TD1

 

 

1

2

3

4

5

6

7

8


10

L

L

L

L

L

L

L

L

24V

1

2

3

4
0V

5

6

7

8

12 - 24VDC

+    -

+    -

1

2

3

4

5

6

7

8


10

L

L

L

L

L

L

L

L

24V

1

2

3

4
0V

5

6

7

8

12 - 24VDC

+    -

Dual Powe

r Source

Single Po

wer So

urce

3.3 - 2

4VDC

P1-08TD1 Wiring Diagram

Module Installation

WARNING:

 

Do not add or remove modules with 

field power applied.

Step One:

 

With latch 

in “locked” position, align 

connectors on the side of 

each  module  and  stack 

by  pressing  together. 

Click  indicates  lock  is 

engaged.

Step Three:

 

To unstack modules, pull 

locking latch up into the unlocked position 

and then pull modules apart.

Step Two:

 

Attach field wiring using 

the removable terminal block or 

ZIP

Link 

wiring system.

WIRE STRIP

LENGTH

MIN

MAX

P1-08TD1

U

N

LO

C

K

LO

C

K

Check all latches are 

secure after modules 

are connected.

Summary of Contents for Productivity 1000 P1-08ND3

Page 1: ... Terminal Block Specifications 4 Warning 4 Terminal Block sold separately see wiring options on page 3 Warranty Thirty day money back guarantee Two year limited replacement See www productivity1000 com for details Input Specifications Inputs per Module 8 sink source Rated Voltage 12 24 VDC Operating Voltage Range 10 2 26 4 VDC Input Current 3 5 mA 12VDC 8 4 mA 24VDC Maximum Input Current 10mA 26 4...

Page 2: ...08TD1 Wiring Diagram Module Installation WARNING Do not add or remove modules with field power applied Step One With latch in locked position align connectors on the side of each module and stack by pressing together Click indicates lock is engaged Step Three To unstack modules pull locking latch up into the unlocked position and then pull modules apart Step Two Attach field wiring using the remov...

Page 3: ...1 CBL10 1P ZL P1 CBL10 2P 3 Screw Terminal Block only P1 10RTB Quantity 1 4 Spring Clamp Terminal Block only P1 10RTB 1 Quantity 1 5 Accessories ZL RTB COM TW SD SL 1 TW SD MSL 1 ZL RTB20 ZL RTB20 1 2 1 Cable ZIPLink Module Complete System 2 ZL RTB COM provides a common connection point for power or ground P1 08ND3 Schematic and Wiring Diagram Single Supply 24VDC 24VDC C1 1 2 3 4 C2 5 6 7 8 1 2 3 ...

Page 4: ...ion or operation If you have any questions concerning the installation or operation of this equipment or if you need additional information please call Technical Support at 770 844 4200 This publication is based on information that was available at the time it was printed At AutomationDirect com we constantly strive to improve our products and services so we reserve the right to make changes to th...