background image

5

Sales 800-633-0405

www.productivity1000.com

Wiring Options

 

1

ZIPLink Feed Through Modules and Cables¹

0.5 m (1.6 ft) cable

1.0 m (3.3 ft) cable

2.0 m (6.6 ft) cable

ZL-RTB20
ZL-RTB20-1

ZL-P1-CBL10
ZL-P1-CBL10-1
ZL-P1-CBL10-2

       Terminal Block with pigtail cable

1.0 m (3.3 ft) cable

2.0 m (6.6 ft) cable

ZL-P1-CBL10-1P

ZL-P1-CBL10-2P

3

Screw Terminal Block only

P1-10RTB
(Quantity 1)

4

Spring Clamp Terminal Block only

P1-10RTB-1
(Quantity 1)

5

 

Accessories²

ZL-RTB-COM

TW-SD-SL-1

TW-SD-MSL-1

ZL-RTB20

ZL-RTB20-1

2

1.Cable + 

ZIP

Link Module = Complete System

2. ZL-RTB-COM provides a common connection point for power or ground

Module Configuration

Using the Hardware Configuration tool in 

the Productivity Suite programming software, 

drag and drop the P1-04ADL-2 module into the 

configuration. 

If desired, assign a 

User Tagname

 to each 

input point (channel) selected and to each 

Status Bit Item

13

Summary of Contents for Productivity 1000 P1-04ADL-2

Page 1: ...5 Input Specifications Input Channels 4 Input Range 0 10 VDC Signal Resolution 13 bit Resolution Value of LSB least significant bit 0 10 VDC 1 22 mV per count 1LSB 1 count Data Range 0 8191 counts In...

Page 2: ...C 4 to 158 F Humidity 5 to 95 non condensing Environmental Air No corrosive gases permitted Vibration IEC60068 2 6 Test Fc Shock IEC60068 2 27 Test Ea Field to Logic Side Isolation 1800VAC applied for...

Page 3: ...IRCUIT POWER ISOLATED ANALOG CIRCUIT COMMON INTERNAL MODULE CIRCUITRY 24V COM COM P1 04ADL 2 Wiring Diagram 24 VDC User Supplied Power Voltage Input Circuits 3 Wire Voltage Transmitter V COM 3 Wire Tr...

Page 4: ...ked position and then pull modules apart Step Two Attach field wiring using the removable terminal block or ZIPLink wiring system LOCK UNLOCK WIRE STRIP LENGTH MIN MAX P1 08TD1 Check all latches are s...

Page 5: ...nal Block only P1 10RTB Quantity 1 4 Spring Clamp Terminal Block only P1 10RTB 1 Quantity 1 5 Accessories ZL RTB COM TW SD SL 1 TW SD MSL 1 ZL RTB20 ZL RTB20 1 2 1 Cable ZIPLink Module Complete System...

Page 6: ...in max The Scale Linear function can be used to Convert an application specific range to range which is native to the analog output module Make other linear conversions in ranges appropriate to the ap...

Page 7: ...7 Sales 800 633 0405 www productivity1000 com...

Page 8: ...he failure to follow all applicable codes and standards We do not guarantee the products described in this publication are suitable for your particular application nor do we assume any responsibility...