![Automation Technology 202 201 005 User Manual Download Page 40](http://html1.mh-extra.com/html/automation-technology/202-201-005/202-201-005_user-manual_3021831040.webp)
38
C2 Series User Manual Rev. 1.9
Description of Modes for Triggering of Sequencer/Frame and Profile
Acquisition
No. Sequencer/Frame Trigger Mode
Profile Trigger Mode
(PTM)
0
Free-run
PTM0 (free-run)
PTM1 (IN1)
PTM2 (IN2)
1
Start/stop over camera input 1 / 2
Continuous frame acquisition is started with the rising edge
of camera input 1 (IN1) and stopped with rising edge of
camera input 2 (IN2)
When “stop” occurs, the frame is not transmitted
immediately over the GigE interface but the camera
continues to acquire profile data, until the predefined frame
height is reached.
PTM0 (free-run)
PTM3 (RS422)
2
Trigger one frame over camera input 1
Single frame acquisition is triggered over the rising edge of
camera input 1 (IN1)
PTM0 (free-run)
PTM2 (IN2)
PTM3 (RS422)
trigger start of sequencer
(frame trigger)
t
trigger stop of sequencer
trigger start of sequencer
(frame trigger)
t
IN1