14
QNix
®
5500
7.2.2. Probe Electrical Data
The probes may only be used with the gauges QNix® 9500 and QNix® 5500.
7.3. Measuring Data
Measuring Data
Fe
NFe
Principle of Measurement
Magnetic field principal
Magnetic field change,
Hall effect
Magnetic field principal
Eddy current
As per standard (varies by model)
DIN EN ISO 2808,
DIN EN ISO 2178
DIN EN ISO 2808,
DIN EN ISO 2360
DIN 50981, DIN 50984, BS 5411 (3 & 11), BS 3900-C5,
ASTM B 499, ASTM D 1400, ASTM D 1186, ASTM D 7091
Status indication
by RGB-LED at the probe
Probe type
See probe data sheet
Measuring range
Varies depending on probe type
Measuring interval
≥ 100 measurements / min.
Units
μ
m / mil (setting in battery compartment)
Display resolution
0,01
μ
m
Measurement uncertainty*
(based on factory standards)
± (1
μ
m + 2 %) to 2 mm
± 3 % from 2 mm
± (2
μ
m + 2 %) to 2 mm
± 3 % from 2 mm
Minimum measuring area (Ø)
14,5 mm
14,5 mm
Minimum curvature radius, convex
6 mm
50 mm
Minimum thickness of the base material
100
μ
m
50
μ
m
* Accuracy may deviate outside a range of -5 °C to 65 °C, but not more than the factor 2 of the
measurement uncertainty..