DPM3 User Manual, 1st Edition
User Manual - DPM3 Series Panel Meters
12
Display and Key Pad
PROG
MIN
MAX
TARE
1
2
3
4
ENTER
DATA
MAX/MIN
MICRA
4
1
2
3
5
6
7
8
9
10
11
12
13
Programming Panel
#
Description
Run Mode
Programming Mode
1
TARE
Indicates tare in the memory
---
2
MAX
Indicates peak displayed
---
3
MIN
Indicates valley displayed
---
4
PROG
---
Indicates programming mode
5
DISPLAY
Displays the input variable
Displays programming parameters
6
TARE (UP) KEY
Takes on the display value
as tare
Increments the value of the flashing digit
7
MAX/MIN (DOWN)
KEY
Recalls Max/Min values
Moves to the right
8
ENTER KEY
Enters in PROG mode.
Displays data
Accepts data. Advances program
9
Free space for units
label
---
10
LED Output 4
Activation Output 4
Programming output 4
11
LED Output 3
Activation Output 3
Programming output 3
12
LED Output 2
Activaton Output 2
Programming output 2
13
LED Output 1
Activation Output 1
Programming output 1
Configuration:
When the power is applied to the meter, a display test begins automatically to check the function
of the LED’s and digits. Once this test is finished the display shows the internal software version
and then the unit goes to
RUN
mode.
Configuration follows a structure composed of a number of menus and submenus. By pressing
the
ENTER
key, the display show “Pro”. Pressing the
SHIFT
key repeatedly provides access
to the main menu level which includes menus for input configuration
(CnInP)
, display
configuration
(CndSP)
, relay configuration if present
(SEtP)
, analog output configuration if