Coal-trol Digital™ – Model TS2 THERMOSTAT
Automation Correct LLC
6/2006 R0
www.automationcorrect.com
Page 10
Instruction Manual
DEG F
SETUP
SETUP Menu Operation
Press UP button for Deg. C or
the DOWN button for Deg. F.
temperature units.
MIN 4
MENU button
MAX 40
MENU button
Starting from the Round-Robin
display, press and hold the
MENU button until SETUP is
shown on the display.
(2 seconds)
MENU button
TBRN N
DISPLAY
ACTION
NOTE
DEG C
UP button
DOWN button
Minimum Stoker Feed Value
Press UP button to increase
MIN feed rate, DOWN to
decrease MIN feed rate.
MIN feed value cannot be
increased beyond the MAX
feed value.
Maximum Stoker Feed Value
Press UP button to increase
MAX feed rate, DOWN to
decrease MAX feed rate.
MAX feed value cannot be
decreased below the MIN feed
value.
The SETUP menu is for initial setup and advanced features.
Under normal operation, these setting need not be adjusted..
TBRN Y
Temperature Units
UP button
DOWN button
Set to 'Y' for Tri-burner type
feeders, otherwise set to 'N'.
SETUP is displayed for only 1
second.
MENU button
S 1154A
SET Time of Day Clock Value
Press UP or DOWN button to
adjust. Display shows 'A' for
AM, 'P' for PM.
After extended power loss, the
time of day setting may be
adjusted without entry into
SETUP menu.
HLF 0
Advanced setting that may
reduce temperature overshoot
after a set point change. The
Heat Loss Factor nominally
represents
the
insulation
quality of the dwelling the
thermostat
is
controlling.
Experimentation
over
a
number of days may be
required.
HEAT LOSS FACTOR
Press UP button to increase,
DOWN button to decrease.
'0' = Minimum Heat Loss
'1' = Low Heat Loss
'2' = Medium Heat Loss
'3' = High Heat Loss
Continued on next page