WARNING! The opener must not 

be used with a door incorporating a 

wicket door.

WARNING! The doors axle must be 

securely clamped otherwise the door 

can loose spring tension.

WARNING! The door and its springs 

are under significant tension. 

Adjustments should only be carried 

out by experienced persons, as 

this function can be dangerous if 

not performed under strict safety 

procedures.

Fig 6.3

6.3.1 Mounting The Opener

a. Check the drive gear rotates freely, by pulling the string handle 

down (there will be a click) to disengage opener. Then move the 

forks from side to side by hand

b. Slide the opener over the door axle and into the drum of the door 

(Fig. 6.3)

.

c. Ensure the internal gear is pushed in as far as possible (without 

interfering with the door curtain) and that the door drum’s wheel 

spokes are completely between the opener’s drive forks.

d. Evenly tighten the supplied nuts on the clamp assembly of the 

opener to a torque setting of 40Nm.

e. Remove the safety rope and door stand or prop.

f.  Connect the power cort to a suitable powerpoint, but 

DO NOT

 

switch on.

g. Secure the power cord away from any moving object (e.g the door) 

with the cable clip supplied.

h. With the opener still disengaged, pull the door up and down to 

make sure it runs freely.

NOTE

 - If the manual release handle is more than 1.8 metres from floor 

level when the opener is installed, extend the handle to a height less 

than 1.8 metres.

6.3.2 Optional Safety Beams

The Safety Beam Kit provides additional safety by preventing the door 

closing when the beam is blocked by a car, child etc. When the Safety 

Beam Kit is installed the Auto-close feature can be enabled if required. 

To install the Safety Beam Kit, refer to the Safety Beam instruction 

supplied with the kit. 

6.3 Fitting the Opener

6.4 Auto-Close 

WARNING! It is compulsory to have 

Safety Beams installed when using  

Auto-Close mode. 

Auto-Close mode is a function that automatically closes the door after 

a pre-set time. Safety beams must be installed in order to run the Auto-

Close function. There are two types of Auto-Close available:

(i)  Standard auto-close - the door will Auto-Close after a programmed 

time. In this mode the timer starts to countdown as soon as the door is 

fully open. This function is useful in case the safety beam does not get 

triggered.

(ii) Safety Beam triggered auto-close - the door will auto-close after a 

programmed time. In this mode the timer starts counting down only 

when the safety beam is triggered. ie car leaving the garage.

To enable the Auto-Close function:

a. Press and release the MODE button until the Spanner LED is 

highlighted.

b. One of the word LEDs (LAMP etc) will highlight. Press the BLUE 

CLOSE button to move to the particular parameter:

(i)  two (2) times to get to PE A/C or

(ii) three (3) times to get to standard A/C.  

c. Press RED STOP / SET button to enter A/C parameter.

d. The OPEN, STOP and CLOSE LEDS will now flash.

The default setting for Auto-Close is OFF. 

e. Press the OPEN button to move through options.

f.  Press the RED STOP / SET button to save the 

parameter’s new value or press MODE to leave the 

value unchanged - flashing will stop. 

LED Indicators

Parameter

OPEN

OPEN & 

STOP

STOP

CLOSE & 

STOP

CLOSE

A/C LED

A/C Function

90s 

60s

30s

15s

OFF

A/C & BEAM LED’S

P.E A/C Function

60s 

30s

15s

5s

OFF

Fig 6.4

Summary of Contents for HiRO GDO-12

Page 1: ...GDO 12 HiR Doc 160421_00 Released 01 04 20 High Rolling Door Opener Installation Manual ...

Page 2: ...ugthathasathird grounding pin This plug will only fit into a grounding type outlet If the plug does not fit into the outlet contact a qualified electrician to install the proper outlet Do not change the plug in any way This operator is not equipped for permanent wiring Contact a qualified electrician to install a suitable receptacle if one is not available September 2018 Automatic Technology Austr...

Page 3: ...6 7 4 Activate Remote Code Set Mode 13 7 Operation Instructions 14 7 1 How to Use Your Opener 15 7 1 1 To Operate the opener 15 7 1 2 Replacing the Battery 3V Lithium Battery CR2032 15 7 1 3 Battery Disposal 15 7 2 User Operating Controls 16 7 3 Door Status Indicators 16 8 Troubleshooting Guide 17 9 After Installation Care 18 9 1 Service Checklist 18 9 2 Battery Replacement 19 9 3 Battery Disposal...

Page 4: ...install the proper outlet Do not change the plug in any way If the power cord is damaged it must be replaced by the manufacturer its service agent or a similarly qualified person in order to avoid a hazard Connect the power cord only to properly earthed mains If an extension lead must be used make sure it is a 3 core lead and approved to 7 amp capacity This unit is not user serviceable Unplug the ...

Page 5: ...or must be well balanced and able to be operated by hand as per warranty conditions and standard AS NZS 4505 2012 6 turns of the drum wheel 270kg 22m2 28m2 Minimum sideroom 35mm IP rating IP20 Receiver type Multi frequency UHF FM 433 47 433 92 434 37MHz Receiver code storage capacity 64 x 4 button Transmitters Number of code combinations Over 100 billion random codes Transmitter battery CR2032 3 V...

Page 6: ... GDO 12 POWER DRIVE UNIT 1 2 INTERNAL GEAR ADAPTER FORKS 3 3 HEX SERRATION HEAD SCREW M6 X 20 6 4 4 BUTTON TRANSMITTERS 2 5 4 BUTTON WALL TRANSMITTER 1 6 LOCKING BAR COVERS 2 GUIDE PACK VR12 7 SCREW EYE 2 8 PLASTIC WALL PLUG 6 9 X 25 1 2 REGISTRATION CARD Please retain for optional smart phone control kit 1 2 3 4 5 6 7 8 ...

Page 7: ...et for right hand side installation This opener must be installed in a dry position that is protected from the weather Moisture or corrosion damage is not covered by the Warranty 4 4 Power Supply Properly earthed 3 pin single phase power is required WARNING Using a portable power generator is not recommended The opener may appear to malfunction due to spikes surges and fluctuations in the generate...

Page 8: ... Section 6 4 3 Resetting Door Limit Positions 6 Installation Instructions IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of severe injury or death 1 READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS 2 Install only on a properly operating and balanced garage door An improperly balanced door has the potential to inflict severe injury Have a qualified service person make repairs to cables...

Page 9: ...be positioned as low as possible in the grove but make sure that it does not alter the curtain s normal lead in to the guide BALLOONING DOOR PINNED DOOR FREE DOOR Pin Points Screw into the low part of grove Check that the door is still balanced and smooth to operate If it is not the door may require servicing refer to door manufacturer s instructions 6 2 1 Door prop preparation a At the end opposi...

Page 10: ...ng when the beam is blocked by a car child etc When the Safety Beam Kit is installed the Auto close feature can be enabled if required To install the Safety Beam Kit refer to the Safety Beam instruction supplied with the kit 6 3 Fitting the Opener 6 4 Auto Close WARNING It is compulsory to have Safety Beams installed when using Auto Close mode Auto Close mode is a function that automatically close...

Page 11: ...desired speed release the CLOSE button iv To set the close limit inch the door by making single presses of the CLOSE button to the desired position We recommend the CLOSE limit position being the first point of contact of the rubber strip at the bottom of the door with the ground v If the door overshoots press the OPEN button to move the door in the OPEN direction vi When the door is at the desire...

Page 12: ...G THE BATTERY THERE ARE NO OTHER USER SERVICEABLE PARTS TESTED TO COMPLY WITH FCC STANDARD FOR HOME OR OFFICE USE OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION NOTE THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMIT...

Page 13: ... NOTE Only the function of the existing transmitter button can be assigned to new transmitter Please read instructions prior to proceeding there is a time out facility for security reasons 6 7 3 Selecting The Function To Be Coded a Using the existing transmitter operate the Door with the transmitter button which has the function to be coded e g Button 1 has been coded with the OSC function assigne...

Page 14: ...RAVEL RETEST THE DOOR OPENER FAILURE TO ADJUST THE OPENER PROPERLY INCREASES THE RISK OF SEVERE INJURY OR DEATH 6 FOR PRODUCTS HAVING AN EMERGENCY RELEASE WHEN POSSIBLE USE THE EMERGENCY RELEASE ONLY WHEN THE DOOR IS CLOSED USE CAUTION WHEN USING THIS RELEASE WITH THE DOOR OPEN WEAK OR BROKEN SPRINGS ARE CAPABLE OF INCREASING THE RATE OF DOOR CLOSURE AND INCREASING THE RISK OF SEVERE INJURY OR DEA...

Page 15: ...th Australian Battery Recycling Initiative please follow the next simple steps for protecting the environment Refer to the Automatic Technology website for information on where to recycle batteries in Australia DO NOT throw the batteries in municipal waste This symbol of the crossed out wheeled bin indicates that the battery should not be placed in the municipal waste Check your local regulations ...

Page 16: ...hen opening Flashing On and door will stop Door obstructed when closing Flashing Beeps while door is moving Opener overloaded Alternating flashes Alternating flashes Mains power interrupted Rapid flashes HELPFUL TIP Refer to Appendix C for Additional LED Indicators tip 7 2 User Operating Controls Button Function 1 BLUE DOWN ARROW Close Button 2 RED STOP SET Stop Set Button 3 GREEN UP ARROW Open Bu...

Page 17: ...ion 7 1 1 Refer to battery status Seciton 7 1 2 Change the position Section 7 1 The door reverses for no apparent reason This may occur occasionally from environmental conditions such as areas that are windy dusty or have extreme temperature changes If Safety Beams are installed they may be partially obstructed Put the door into manual Section 5 take note of the CAUTION and contact 1300 133 944 En...

Page 18: ... mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure the door opens and closes to specification 5 Assessment and adjustment of safety components and accessories including safety beams Auto Lock and Safe Lock if installed 6 Assessment of the door alignment and the di...

Page 19: ...tter button Check Light Status table to determine if battery needs replacing Light Status Battery Status Solid OK Flashing Requires replacement No light Requires replacement Use a pen to push the battery down through the side opening to release battery Use finger nails to separate the transmitter casing to expose circuit board Use a non metallic object e g pen to remove the battery Some batteries ...

Page 20: ...he OPEN STOP and CLOSE LEDS will now flash and indicate the parameters value as shown in table below f Use the BLUE CLOSE or GREEN OPEN buttons to adjust the parameter value by one step up or down g Press RED STOP SET to save the new value or MODE to cancel the edit flashing will stop h To enter another parameter repeat from Step a Appendix When activated PET mode drives the door to a preset posit...

Page 21: ... auto close timer was paused due to the beam being blocked FLASHES to indicate the auto close timer is running BEAM LED On STEADY when a beam is blocked FLASHES when there is a P E Fault OBST LED On STEADY Obstruction was detected If door open then obstruction was while closing and vice versa FLASHES Stall Overload detected If door open then stall overload while closing and vice versa SPANNER LED ...

Page 22: ... the button 4 will move the door to desired limit ii While inching to CLOSE to set the close speed press and hold button 4 on the remote and by pressing the SET button 2 the opener will cycle through all three speed modes as shown in table iii Once at the desired speed release the remote button 4 iv Continue inching the door to the desired position We recommend the CLOSE limit position being the f...

Page 23: ... button f Press the transmitter button to test E 3 Transmitter Button to Operate PART Partial Mode The PART mode position see 11 Setting Partial Open Position must set prior to coding a transmitter a Press the MODE button to highlight the CODE LED if not already highlighted b Use the BLUE CLOSE or GREEN OPEN buttons to scroll through to highlight the PET LED c Press and hold the RED STOP SET butto...

Page 24: ...chnology office location Head Office 6 8 Fiveways Blvd Keysborough 3073 Phone 03 9791 2000 ata aust com au Prefixed trademarks are the property of Automatic Technology Australia Pty Ltd ABN 11 007 125 368 2020 Automatic Technology Australia Pty Ltd ...

Reviews: