background image

34

34

G

B

D -  

SETTING THE TIME FOR 2 MOTORS (#) WITH TIME OPERATION 

(DIP 7 OFF)

1 -  The gate must be completely closed.
2 -  Set DIP 2 to ON => LED DL1 will blink rapidly.
3 -  Press the PROG button. => M1 opens.
4 -  When  the  mechanical  opening  stop  is  reached,  wait  a  second  then  press  the 

PROG button => M1 stops and M2 opens.

5 -  When the mechanical opening stop is reached => wait 1 second and press the 

PROG button => M2 stops.

6 -  Press the PROG button => M2 closes.
7 -  Press the PROG button => M1 closes setting the time lag between M2 and M1.
 

 At the same time LED DL1 stops flashing indicating exit from the programming 
procedure.

 

 Safety  and  other  gate  commands  now  operate  normally  (inversions,  stop, 
alarms, etc.).

8 -  After the set amount of time, the gate will stop.
9 -  

AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.

NOTE:

  The  slowdown  is  automatically  determined  by  the  control  board  during 

the time setting phase and is activated at about 50 to 60 cm before reaching the 
mechanical opening or closing limit.

D -  

SETTING THE TIME FOR 1 MOTOR (#) WITH TIME OPERATION 

(DIP 7 OFF)  

CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST SET TO ON

1 -  The gate must be completely closed.
2 - Set micro-switch DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button => M1 opens.
4 -  When  the  mechanical  opening  stop  is  reached,  wait  a  second  then  press  the 

PROG button => M1 stops.

5 -  Press the PROG button => M1 closes.
 

 At the same time LED DL1 stops flashing indicating exit from the programming 
procedure.

 

 Safety  and  other  gate  commands  now  operate  normally  (inversions,  stop, 
alarms, etc.).

6 -  After the set amount of time, the gate will stop.
7 - 

AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.

D -  

SETTING PEDESTRIAN OPENING TIMES (#) BOTH FOR TIME AND 

POWER SENSOR OPERATION

With gate closed:
1 - First set DIP2 to ON (LED DL1 flashes quickly) and then DIP1 to ON ( LED DL1 
flashes slowly).
2 - Push the pedestrian button (COM-PED.BUTT) => M1 opens.
3 - Push the pedestrian button to stop movement (thereby setting M1 opening).
4 - Push the pedestrian button to start closing.
5 - Upon closing reset DIP 1 and 2 to OFF.

(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND STOP 
THE  PROGRAMMING  PROCEDURE  (LED  DL1  FROM  FLASHING  BECOMES 
CONSTANT). 
TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE GATE USING 
THE  PROCEDURE  “MOTOR  ROTATIONAL  DIRECTION  CONTROL”  AND 
REPEAT THE DESIRED PROGRAMMING PROCEDURE.

E -  

RADIO CODE PROGRAMMING FOR TOTAL OPENING

(UP TO 62 CODES - CRX MODELS ONLY)

Programming can be done only when the gate is stationary.
1 -  First set DIP 1 to ON and then DIP 2 to ON.
2 -  The red LED DL1 flashes ON every 1 sec. and OFF for 10 seconds.
3 -  Press  the  remote  control  button  (usually  channel  A)  within  the  allotted  10 

seconds. If the remote is memorized properly LED DL10 (green) blinks.

4 -  The programming time for codes is automatically renewed in order to memorize 

the next remote control.

5 -  To finish programming, wait 10 seconds, or press the PROG button briefly. The 

red LED DL1 stops flashing.

6 -  Reset DIP 1 to OFF and DIP 2 to OFF.
7 -  End of procedure.

CANCELLATION OF ALL RADIO CODES FOR TOTAL OPENING

Cancellations can only be performed when gate is stationary.
1 -  Set DIP 1 to ON and then DIP 2 to ON.
2 -  The red LED DL1 flashes ON every 1 second and OFF for 10 seconds.
3 -  Press and hold the PROG button for 5 seconds. Memory cancellation is indicated 

by two flashes of green LED DL10.

4 -  The red LED DL1 remains active and you can add new codes as shown above.
5 -  Reset DIP 1 to OFF and DIP 2 to OFF.
6 -  End of procedure.

INDICATOR MEMORY FULL OF RADIO CODES FOR TOTAL OPENING

Indication only when gate is stationary.
1 -  Set DIP 1 to ON and then DIP 2 to ON.
2 -  The green LED DL10 flashes 6 times when the memory is full (62 codes).
3 -  LED DL1 will then remain active for 10 seconds enabling possible cancellation 

of codes.

4 -  Reset DIP 1 to OFF and DIP 2 to OFF.
5 -  End of procedure.

F -  

PROGRAMMING PEDESTRIAN OPENING RADIO CODES 

 (UP TO 62 CODES - CRX MODELS ONLY)

Programming can be done only when the gate is stationary.
1 -  Set DIP 1 to ON and then DIP 3 to ON.
2 -  The red led DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.
3 -  Press  the  remote  control  button  (usually  channel  B)  within  the  allotted  10 

seconds. If the remote is properly memorized LED DL10 (green) blinks.

4 -  The programming time for codes is automatically renewed in order to memorize 

the next remote control.

5 -  To finish programming wait 10 seconds, or press the PROG button briefly. The 

red LED DL1 stops flashing.

6 -  Reset DIP 1 to OFF and DIP 3 to OFF.
 

 

NOTE: If LED DL1 CONTINUES BLINKING QUICKLY IT MEANS THAT DIP 1 
IS STILL SET TO ON AND THAT ANY OPERATION IS REFUSED.

7 -  End of procedure.

CANCELLATION  PROCEDURE  FOR  ALL  PEDESTRIAN  OPENING  RADIO 
CODES

Cancellation can only be performed when the gate is stationary.
1 -  Set DIP 1 to ON and then DIP 3 to ON.
2 -  The red LED DL1 flashes ON for 1 second and OFF for 1 second for 10 seconds.
3 -  Press and hold the PROG button for 5 seconds. Memory cancellation is indicated 

by two flashes of green LED DL10.

4 -  The red LED DL1 remains active and you can add new codes as shown above.
5 -  Reset DIP 1 to OFF and DIP 3 to OFF.
6 -  End of procedure.

INDICATION MEMORY FULL OF PEDESTRIAN OPENING RADIO CODES

Indication only when the gate is stationary.
1 -  Set DIP 1 to ON and then DIP 3 to ON.
2 -  The green LED DL10 flashes 6 times when the memory is full (62 codes).
3 -  The  LED  DL1  will  then  remain  active  for  10  seconds  enabling  possible 

cancellation of codes.

4 -  Set DIP 1 to OFF and DIP 3 to OFF.
5 -  End of procedure.
 

C

ONTROL ACCESSORIES OPERATION

ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED.
Make sure that any other type of command accessories (e.g. mass detectors) 
used on the installation are set in the IMPULSIVE mode, otherwise, the gate 
will be operated even without the protection of the safety devices.

STEP-BY-STEP BUTTON (COM-K BUTTON)
If DIP6 ON =>

 

 It  cyclically  performs  the  commands  open-stop-close-stop-open 
etc.

If DIP6 OFF =>

   Opens  the  gate  when  closed.  There  is  no  effect  if  activated 

while opening. If activated when gate is open, the gate closes. If 
activated while closing, the gate reopens.

OPEN BUTTON (COM-OPEN)

The button controls the opening movement when the gate is stationary. If activated 
while closing, it reopens the gate.

CLOCK FUNCTION OF OPEN BUTTON

If you want the Clock Function must request T2 24V with firmware 02.
ATTENTION:  A  CLOCK  CONNECTED  TO  T2  24V  with  fw  03  or  more 
ACTIVATES THE OPENING MOVEMENT OF THE GATE WITHOUT HAVING 
THE PROTECTION OF THE SAFETY DEVICES!

This function is useful during peak hours, when vehicle traffic is slow (e.g. entry/
exit  of  workers,  emergencies  in  parking  or  residential  areas  and,  temporarily,  for 
moving operations).

Summary of Contents for KING 24V

Page 1: ...00 AA14028 Peso max cancello Poids maxi portail Max gate weight Max Torgewicht Peso máx verja 400 kg 880 lbs KING 24V L 24Vdc N 1800 AA14029 500 kg 1100 lbs ITALIANO pag 05 FRANÇAIS pag 16 ENGLISH page 27 DEUTSCH pag 38 ESPAÑOL pag 49 OPERATORE IRREVERSIBILE PER CANCELLI A BATTENTE OPERATEUR IRREVERSIBLE POUR PORTAILS À BATTANT IRREVERSIBLE OPERATOR FOR LEAF GATES TORANTRIEBE FÜR FLÜGELTORE OPERAD...

Page 2: ...L DATA Max leaf length Max leaf weight Max travel Average opening time Operating speed Thrust force EEC Power supply Motor capacity Power absorbed Daily operations suggested Service Guaranteed consecutive cycles Grease Weight of electroreducer Noise Volume Operating Temperature Protection m 3 5 4 5 kg 400 500 mm 345 475 s 14 27 29 38 m s 0 0125 N 1800 24V W 118 A 5 4 n 150 90 n 200 14s Bechem RHUS...

Page 3: ... If there is an iron pillar you can weld the attachment directly If there is a cement pillar you can use the fixing plate as in Fig 5 which is fastened with 4 Fischer screws of Ø 8 mm There is also the possibility to cement the attachment welding an anchor at its base Fig 6 Naturally you have to respect predetermined fixing measures Afterwards you must weld the other actuator s attachment to the g...

Page 4: ...s must be checked That the gate is endowed with appropriate handles That these appropriate handles are placed so to avoid safety risks for the operator That the physical effort necessary to move the gate leaf should not be higher than 225 N for doors gates for private dwellings and 390N for doors gates for commercial and industrial sites values indicated in 5 3 5 of the EN 12453 norm MAINTENANCE T...

Page 5: ...5 B 115 200 140 815 115 27 B 105 190 190 945 150 26 D 160 214 120 945 150 20 D L Min Max a A max T sec B C D E 1 1 80 1 81 2 20 2 21 2 50 2 51 3 00 3 01 3 50 3 51 4 00 110 20 90 140 815 90 20 A 100 130 815 90 21 A 110 140 815 115 24 B 130 140 945 120 29 C 160 150 945 120 19 C 160 230 945 150 22 D L Min Max a A max T sec B C D E ANT ANT KING 24V KING 24V KING 24V KING 24V KING 24V KING 24V L KING 2...

Page 6: ...ENNA ANTENNA BRAIDING CLOSE OPEN STOP FUSE T 2 A PHOTOCELLS STEP BY STEP COMMON COMMON 24Vdc 0 8A 15 for ACCESSORY SUPPLY 24Vdc 0 8A 15 for AUTOTEST SAFETY STRIPS BLINKER 24Vdc 20W LED R 2 2K 1 4W ELECTRIC LOCK PEDESTRIAN SAFETY STRIPS POWER SUPPLY 230Vac 50 Hz TRANSFORMER M1 M2 ...

Page 7: ...amming DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK Connector dedicated to the factory programming only CRX control board DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK Built in radio module model CRX or connector for radio receiver RIB 24 Vdc supply Connector for charge card of 24Vdc battery code ACG4648 Trimmer for high speed adjustment operations Trimmer for low ...

Page 8: ...gate opening M1 green DL5 gate closing M1 red DL6 automatic closing indicator red DL7 photocell contact NC red DL8 sensor contact NC red DL9 STOP button NC red DL10 radio code program green FUSES Fuse 1 T 8A MOTOR PROTECTION FUSE F1 T 2A TRANSFORMER PROTECTION FUSE on the outside of the T2 24V board C MOTOR ROTATIONAL DIRECTION CONTROL 1 Set DIP 1 to ON LED DL1 starts flashing 2 Press and hold the...

Page 9: ... PROG button for 5 seconds Memory cancellation is indicated by two flashes of green LED DL10 4 The red LED DL1 remains active and you can add new codes as shown above 5 Reset DIP 1 to OFF and DIP 2 to OFF 6 End of procedure INDICATOR MEMORY FULL OF RADIO CODES FOR TOTAL OPENING Indication only when gate is stationary 1 Set DIP 1 to ON and then DIP 2 to ON 2 The green LED DL10 flashes 6 times when ...

Page 10: ... movement in front of the photocells is deactivated N B Please check photocell operation at least every six months EDGE SAFETY STRIP COM EDGE If engaged during opening reverses the motion when closing If engaged when closing reverses the motion when opening If it remains engaged again it performs a further reversal after 2 seconds then performs an additional short reversal and then gives the senso...

Page 11: ...eceiving Frequency 433 92 MHz Impedance 52 OHM Sensitivity 2 24µV Pick up time 300ms Drop time 300ms All inputs must be used as clean contacts because the power is generated internally secure power to the board and is set up to ensure compliance with double or reinforced insulation with regard to dangerous voltage Any external circuits connected to the outputs of the control panel must be made in ...

Page 12: ...0V ac dc code ACG6099 NOVA Wi Fi PHOTOCELLS WITHOUT WIRES code ACG8037 PAIR OF COLUMS NOVA code ACG8039 TOUCH Wi Fi STRIP WITHOUT WIRES code ACG3016 SPARK Wi Fi BLINKER WITHOUT WIRES code ACG7064 LATERAL SUPPORT code ACG7042 BLOCK Wi Fi KEY SELECTOR WITHOUT WIRES code ACG6098 Discover the only wireless automation devices at www ribind it SET SOLAR AMPLIFIER Interface for 50W solar panels code AD00...

Page 13: ...fissaggio colonna KING L Piatto attacco cancello KING L Attacco cancello serie KING Angolare attacco a colonna 2 pezzi KING Piastra attacco colonna KING L Cuscinetto motore 6005ZZ Condensatore 10µF 450V x serie 230V 50 Codice Denominazione Particolare CEL1426 CME1166 CME1299 CME2042 CME2041 CME8996 CME9129 CME9130 CME9785 CME9868 CMO2515C CPL1087 CPL1157 CPL1161 CRS62042R CTC1004 CTC1008 CTC1119 C...

Page 14: ...service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defec...

Reviews: