M
ODE
S
ELECTION
Using the mode selection dip-switches select the desired operating modes. Note the times associated with
the parameters marked with an * can be changed. The auto-close times can be changed using the procedure
in the following section. See the instruction manual for details on how to change the other parameters.
See the detailed instruction manual for details on how to change the other parameters.
Position 1
SYNCHRONISING DELAY
OFF - No delay
ON -
Motor 1 starts to open 2 seconds* before Motor 2 and Motor 2 starts to close 2 seconds* before
Motor 1.
Position 2
PULSE LOCK OUTPUT
OFF - Lock output is activated for the entire motor drive cycle.
ON -
Lock output pulses for 0.3 seconds* at the start of each drive cycle.
Position 3
LIGHT OUTPUTS WARNING
OFF - Optional light module controls a light with timer which turns light off after 60seconds*.
ON -
Optional light module controls a warning light which activates whenever motors are on.
Position 4
SWIPE MODE (OSC INPUT)
OFF - OSC input terminal has standard Open, Close, Stop action.
ON -
OSC input terminal will only open the door/gate. The input also resets the P.E triggered
auto-close mode so that the P.E input will need to be triggered again before a P.E auto-
close cycle will be initiated.
Position 5
M 2 OUTPUTS STATUS
OFF - The M2 output controls second motor
ON -
The M2 output controls status lights
Position 6
P.E STOPS CLOSE CYCLE
OFF - Activating the P.E input while motors are closing causes the motors to reverse.
ON -
Activating the P.E input while motors are closing causes the motors to stop but not reverse.
Position 7
P.E STOPS OPEN CYCLE
OFF - Activating the P.E input while motors are opening is ignored by the controller.
ON -
Activating the P.E input while motors are opening causes the motors to stop.
Position 8
P.E TRIGGERED AUTO-CLS
OFF - Not selected
ON -
Selects the P.E triggered auto-close mode which causes the motors to auto-close if
the P.E input is activated then released. (Auto-close delay time is 0 seconds*)
Position 9
PEDESTRIAN AUTO-CLS
OFF - No pedestrian access auto-close
ON -
Selects auto-close in the pedestrian access mode. (Auto-close delay time is 15
seconds*)
Position 10
STANDARD AUTO-CLS
OFF - Not selected
ON -
Selects standard auto-close mode which will close the motors after fully opening.
(Auto-close delay time is 30 seconds*)